JBC MVE Pneumatic Desoldering Module for DDU and DMU Instruction Manual

June 5, 2024
JBC

JBC - logo MVE Pneumatic Desoldering Module for DDU and DMU
wwwibctools.com

Instruction Manual

This manual corresponds to the following reference: MVE-A

Packing List

The following items are included:

Features and Connections

Compatibility

Select the equipment that best suit your soldering or desoldering needs.

Module| Stand| Tool| Tip
Range| Control Units| Peripherals
---|---|---|---|---|---
DDU| DMU| P405
MVE| OSS| DS360| C360| | |
DRS| DR560| C560| | |

Initial Set up

After connecting the module, enter the Peripherals Menu and select the port which you want to join with the module.
For DDU Control Unit

  1. Select the module from the list of peripheral Remember your first connection is denoted as “a–, the second being “b”, etc. (e.g. MVE_a, MVE_b,…)
  2. Press Menu or Back to save changes. Once set up, you can change the module settings by entering the Peripherals

For DMU Control Unit

When a new module is detected, a pop-up screen appears.

  1. To configure your Electric Suction Module press Setup in the popup window.

  2. Select the module from the list of peripheral Remember your first connection is denoted as “a*, the second being “b”, etc. (e.g. MS_a, MS_b,…). Do the same with the pedal (e.g. PD_a,…)

  3. Select the port of the tool you want to link to the peripheral.

  4. Press Menu or Back to save Once set up, you can change the module settings by entering the Peripherals Menu.

Maintenance

Before carrying out maintenance, always unplug the electric and pneumatic connectors.

  • Use a damp cloth to keep the casing clean.
  • Periodically check all cable and tube connections.
  • Keep filters clean to ensure proper solder suction and replace them when necessary.

Important: Do not use sharp pointed objects to open the suction filter.

  • Use original JBC spare parts on
  • Do not work with defective or damaged pieces.
  • Repairs should only be performed by a JBC authorized technical service.
  • Maintenance must not be carried out by children unless supervised.

Removing Pneumatic Tubing

Push the release ring (1) to
remove the pneumatic tubing (2).

Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.

  • Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.

  • The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.

  • Do not work on electrically live parts.

  • The tool should be placed in the stand when not in use in order to activate the sleep mode. The soldering tip or nozzle, the metal part of the tool and the stand may still be  hot even when the station is turned off. Handle with care, including when adjusting the stand position.

  • Do not leave the appliance unattended when it is on.

  • Do not cover the ventilation grills. Heat can cause inflamable products to ignite.

  • Avoid flux coming into contact with skin or eyes to prevent irritation.

  • Be careful with the fumes produced when soldering.

  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.

  • Utmost care must be taken with liquid tin waste which can cause burns.

  • This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they  have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved.
    Children must not play with the appliance.

  • Maintenance must not be carried out by children unless supervised.

Notes _____

Specifications

MVE
Pneumatic Desoldering Module for DDU & DMU
Ref.: MVE-A

-Net Weight: 700 g / 1.54 lb
– Module Dimensions: 225 x 145 x 55 mm / 8.86 x 5.71 x 2.17 in
 Air Pressure Supply Range: 4 – 6 Bar
– Vacuum at 6 Bar: 90% / 680 mmHg / 26.8 inHg
– Flow Rate: 15 SLPM
– Ambient Operating Temperature: 10 – 40 ºC / 50 – 104 ºF
 -Pedal connection
 – Total Package Dimension / Weight:   (L x W x H) 280 x 195 x 115 mm / 1000

g
11.02 x 7.68 x 4.53 in / 2.20 lb

Complies with CE standards.
ESD safe.

JBC - logo

Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

www.jbctools.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>