JBC FAE1 Fume Extractor for 1 Workbench Instruction Manual

June 5, 2024
JBC

JBC FAE1 Fume Extractor for 1 Workbench

Packing List

The following items are included:JBC-FAE1-Fume-Extractor-for-1-Workbench-
fig-1

  • Fume Extractor for 1 Workbench …. 1 unit
  • Filter for FAE1 ………………………………………. 1 unit Ref. FAE1-100 (already assembled)
  • Premium Station Cable (RJ12) ………… 2 units Ref. 0019751
  • Power Cable ……………………………………. 1 unit Ref. 0023715 (100V / 120V) 0023714 (230V)
  • Compact Station Cable (USB A/B) …… 1 unit Ref. 0021042
  • Compact Station Adapter (RJ12 to USB A) …………………………………. 1 unit Ref. 0023504

Features and Connections

JBC-FAE1-Fume-Extractor-for-1-Workbench-
fig-4

Assembly Options

Workbench ConfigurationJBC-FAE1-Fume-Extractor-for-1-Workbench-
fig-5

Workbenches ConfigurationJBC-FAE1-Fume-Extractor-for-1-Workbench-
fig-6

Station Connections for Premium Range

JBC Soldering Stations feature a robot port to the fume extractor in order to automatically activate the extraction when the tools are in use. Use the Premium Station Cable (included) for the connection.

JBC-FAE1-Fume-Extractor-for-1-Workbench-fig-8

Connect up to 4 stations directly to a fume extractor through the soldering station robot port. Every tool connected to a station can control the aspiration system. Each Station detects the fume extractor as “FAE_a”. The tool that should activate the fume extraction need to be configured through the peripheral menu option on the station menu. Note: For a correct operation always update soldering stations with the latest available software version. The minimum required version is 8886160 for DDE, HDE and NAE stations and 8886162 for DME stations.

Station Connections for Compact Range

Use the Compact Station Cable and the Adapter cable to connect JBC Soldering Stations. They feature a USB-B port to the fume extractor in order to automatically activate the extraction when the tools are in use.

Equipment Software Update

JBC Updater
The fume extractor can be updated via the USB-B connection by means of JBC Updater software. Download software from: www.jbctools.com/software.html. Note: For the updating process the Premium Station Cable (RJ12) has to be disconnected. If a station is connected to RJ12 connector the update process will not start.

Main Menu ParametersJBC-FAE1-Fume-Extractor-for-1-Workbench-
fig-12

JBC-FAE1-Fume-Extractor-for-1-Workbench-fig-13

Fume Extractor Activation

Once the fume extractor is turned on, the display shows a similar screen as the following one and the filter saturation indicator is green if the carbon filter lifetime is higher than 20%. If the display shows STOP#4, power off the fume extractor, remove the cover, place it back and secure it by using the quick-release levers.

Parameters

Port

JBC-FAE1-Fume-Extractor-for-1-Workbench-fig-15

Filter Set
JBC-FAE1-Fume-Extractor-for-1-Workbench-fig-16

Extraction Control

Fume extractor aspiration may be controlled by: Pedal Connection By means of the pedal connection, fume extractor aspiration may be activated/deactivated by P-005 or P-405 pedal. (See pedal activation modes on the previous page)

Fume Extractor Configurations

Some parameters, features and the performance vary depending on fume extractor configuration, see the following table:JBC-FAE1-Fume-Extractor-for-1
-Workbench-fig-18

Maintenance and Filter Replacement

  •  The unit notifies through both the display and the LED when filters need maintenance.
  •  To replace the filters remove the cover by opening the quick release levers of the casing.
  •  If the saturation indicator remains in red after changing the pre-filter, it means that the HEPA filter is already saturated and must be replaced too (see filter replacement instruction on page 16).
  •  When the HEPA filter has been replaced, the carbon filter counter must be reseted (Main Menu > Filter Set > Reset Carbon).
  •  The duration of the compact filter is a maximum 1 year after its packaging is opened.
  •  If the filter is changed while the fume extractor is on, the unit starts the filter detection process, activating aspiration for a few seconds.JBC-FAE1-Fume-Extractor-for-1-Workbench-fig-19

Quick Release Lever Adjustment

Turn clockwise to loosen and counterclockwise to tighten, in order to adjust the filter airtightness.

AccessoriesJBC-FAE1-Fume-Extractor-for-1-Workbench-
fig-21

Safety

  • The equipment is only designed to filtrate the fumes generated by soldering.
  •  Do not use the units for the filtration of combustible, explosive or corrosive gasses. Incorrect use may cause fire.
  •  The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
  •  Do not leave the appliance unattended when it is on.
  •  Do not cover the ventilation grills. Heat can cause inflammable products to ignite.
  •  This appliance can be used by children over the age of eight and persons with reduced capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved.
  •  Maintenance must not be carried out by children unless supervised.
  •  Keep your workplace clean and tidy. Wear an appropriate protective mask, glasses, and gloves when handling dirt filter or pre-filter.
  •  Do not use the equipment without the filters.
  •  Saturated filters can not be cleaned and reused.
  •  Avoid blowing the filter or the dirty parts of the equipment, if necessary it is advisable to vacuum.
  •  Avoid losing particles in the filter during handling it.

Specifications

Fume Extractor for 1 Workbench
Ref.: FAE1-1B 100V 50/60Hz. Input power: 105W. Fuse 2A 120V 50/60Hz. Input power: 135W. Fuse 2A
Ref.: FAE1-2B 230V 50/60Hz. Input power: 115W. Fuse 1.25A

  •  Blower Type: Brushless
  •  Blower max. Flow Rate: 180 m³/h (106 CFM)
  •  Blower max. Vacuum: 3.2 kPa (0.46 psi)
  •  Work Areas (Workbenches): 1 or 2
  •  Noise: 55 dB @ 1m
  •  Pre-Filter: Medium dust filter M5 (EN 779)
  •  Compact Filter: HEPA filter H13 (EN 1822) Carbon filter
  •  Connections: USB-B Pedal connector Station connectors (4x)
  •  Total Net Weight: 10.50 kg / 23.15 lb

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals