JBC PHBE-1KA PHBK Large Preheater Set Instruction Manual
- June 5, 2024
- JBC
Table of Contents
JBC PHBE-1KA PHBK Large Preheater Set
Packing List
The following items are included:
-
Large Preheater Unit ………………………… 1 unit
-
Large PCB Support ………………………….. 1 uni t
Ref. PHB-SA -
Console .. ……………………. 1 unit
Ref. ACE-A -
Power Cord …………………1 unit
Ref. 0023715 (120V)
0023714 (230V)
0024092 (100V) -
RJ45 Cable ……………… 1 unit
Ref. 0019914 -
Kapton Tape ……………… 1 uni t
Ref. PH217 -
Thermocouple .. ………… 2 uni t
Ref. PH218 -
Manual ………………………. 1 unit
Ref. 0026987
Features and Connections
Preheater Unit
Console Support
Height Adjustment
PSB, the Large PCB Support, allows to change the heigth between the PCB and the preheater heating area. To change the height, do as follows:
- To raise the support, hold the base and pull up.
- To lower the support, press the button and push down.
It can be choosen between 3 positions for the working height adjustment:
- Low level 28 mm
- Medium level 38 mm
- High level 48 mm
Fast PCB Replacement
The Large PCB Support lets you replace PCBs of the same batch fast and easily. Use the sliding guides to change the PCBs.
- Removing the PCB: Loosen one sliding guide, pull back and lift out the PCB.
- Placing another PCB : Position it and tighten the sliding guide knobs.
Reworking large PCBs
Use the 4 rubber caps to place PCBs larger than the support or thicker than 3mm.
- Remove both guides by untightening the 8 screws.
- Place the PCB on the 4 rubber caps.
- The PCB is ready to work.
Work Screen
The Console offers an intuitive user interface which provides quick access to station parameters.
System notifications (Status Bar)
- USB flash drive is connected.
- Station is controlled by a PC.
- Station is controlled by a robot.
- Station software update. Press INFO to start the process.
- Warning.: Press INFO for failure description.
- Error. Press INFO for failure description, the type of error and how to proceed.
Available languages: English, Spanish, German, French, Italian, Portuguese, Japanese, Chinese, Russian and Korean.
Troubleshooting
Station troubleshooting available on the product page at www.jbctools.com
Setting Thermocouples Function
Select Thermocouples from the Work mode menu to set them up. The thermocouples (TC) can work in three diferent ways depending on what is needed.
- · Control: the unit mantains the selected temperature.
- · Protection : the Heater Unit stops if the TC reaches the selected temperature.
- Info : the TC temperature is shown in the work screen.
The TC1 is always working in Control mode for the Temperature mode as well as for Profiles mode. The temperature of each TC can also be selected from the work screen.
Recommended Guidelines
-
Place the control thermocouple as near as possible to the component being worked on.
-
If there are any sensitive components, use a thermocouple as protection.
You can select the protection temperature in the thermocouples menu. If the selected temperature
is reached, the Heater Unit will stop the process and a warning message will be shown. -
IPC does not recommend exceeding ramp-up rates over 3 – 4 °C / sec (5 – 7 °F / sec) so as to reduce the risk of thermal stress on the PCB.
IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits and is committed to becoming the most recognized international industry association for the electronics manufacturing industry.
Work Mode
Temperature Mode:
Select Temp. mode from the Work mode menu. In this mode the heater unit
maintains the selected temperature for the TC1 thermocouple as long as the
other TC’s do not reach the control/protection
temperature limit.
Working within the Temperature Mode the maximum heating rate value (Max Rate) can be defined (1).
This function allows you to set a maximum value for the temperature increase
per second when heating.
The maximum heating rate value can be set between 0.1ºC/s and 2.0ºC/s (2) or
“None” if this function is not desired.
Power Mode:
Select Power mode from the Work mode menu. In this mode the heater unit maintains the selected Working within the Temperature Mode the maximum heating rate value (Max Rate) can be defined (1).
Profile Modes
Select Profile Mode from the Work Mode Menu. In this mode the heater unit regulates the temperature of the TC1 thermocouple according to the selected profile as long as the other TCs do not reach the control/protection temperature limit. Teach Profile
For repetitive jobs you running profiles without the thermocouple (TC). In
order to do so, the Teach
profile mode has to be executed before running any profile. It can be executed
from the Work mode menu if the Profiles mode is selected. Once the profile has
been run to the end, the system has all the process data which you can save.
Once it is saved, you can run this profile without connecting the thermocouple
(TC). The heating process will be the same as long as the same working
conditions are respected. The profiles which already have the data from the
Teach profile are marked with this symbol These profiles can be run either
with or without the Thermocouples. It can be chosen from the Profiles mode
work screen: Profile Editor
The Profile editor can be opened from the main menu or from the Profiles mode
work
screen by pressing the ‘OK’ button. In this mode you can edit as many as 25
profiles of temperature. JBC Set Profiles
There are 3 profiles predefined by JBC: A, B and C. The difference between them is the number of steps: 2, 3 or 4. The thicker your PCB is and the more layers it contains, the more steps are needed to obtain a gradual warming. These profiles are not modifiable but can be used as a template to create your own profiles. Process Analysis
By pressing Graphics in the main MENU, temperature of TC1 thermocouple and power figures in real time are displayed.
System Notifications
The following icons will be displayed on the screen’s status bar.
- USB flash drive is connected.
- Station is controlled by a PC.
- Station is controlled by a robot.
- Station software update. Press INFO to start the process.
- Warning.: Press INFO for failure description.
- Error. Press INFO for failure description, the type of error and how to proceed.
Files
- Export Graphics : Insert a USB flash drive into the USB-A connector to save your soldering process in csv format.
- Export / Import Profiles : Insert a USB flash drive into the USB-A connector to export / import profiles.
Update the Station Software
- Download the JBC Update File from www.jbctools.com/software.html and save it on a USB flash drive. (Preferably one with no other files).
- Insert the USB flash drive to the console. The icon is diplayed while updating.
Working with Pedal
Press the pedal to start heating and press again to stop as if it was the button on the console. Once the Work Mode is set, the Heater Unit can work without the console using the pedal.
Maintenance
Before carrying out maintenance or storage, always allow the equipment and the support to cool down.
- Check periodically that the Pre Heater and the Support are clean.
- Use a damp cloth when cleaning. Alcohol can only be used to clean the metal parts.
- Only if it is absolutely necessary and if cleaning with isopropyl alcohol (IPA) is not enough, it is recommended to use a scraper to remove dirt in the glass area.
- Replace any defective or damaged parts. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
Safety
****It is imperative to follow safety guidelines to prevent electric shock,
injury, fire or explosion.
- Do not use the units for any purpose other than PCB preheating. Incorrect use may cause fire.
- The mains cable must be plugged into approved bases. Make sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
- The temperature of accessible surfaces may remain high after the unit is turned off. Handle with care.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Heat can cause inflamable products to ignite even when out of sight.
- Be careful with the remains of liquid tin. In contact with skin, it can cause burns.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the smoke produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
- This appliance can be used by children over the age of eight as well as persons with reduced physical, sensory or mental capabilities or lacking experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
Specifications
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.
This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>