Eaton Wiring Devices TR7765W-BOX Combination 3.6A USB Charger User Manual

June 5, 2024
Eaton Wiring Devices

Eaton Wiring Devices TR7765W-BOX Combination 3.6A USB Charger

Combination Receptacle / USB Charger

APPLICABLE MODEL NUMBER

  • R1615S21
  • R1615S30
  • R1615S36
  • R1615S40
  • R1615D21
  • R1615D30
  • R1615D36
  • R1615D40
  • R1620D21
  • R1620D30
  • R1620D36
  • R1620D40

FEATURES

  1. The Receptacle provide two 5V DC powered USB ports with a total of 2.1/3.0/3.6/4.0A charging current.
  2. Charge most compatible electrical device directly without an adapter.
  3. If the devices combined power requirements exceed the power capacity of the USB ports, the charger will shut down to protect your electrical devices.
  4. Replace a standard single or duplex receptacle.
  5. Compatible with USB 2.0/3.0 devices. The USB ports are used to charge portable electronic devices ONLY (NO data transfer capability).
  6. Back and side wire for easy installation.

COMPATIBILITY

The USB charger is compatible with USB powered devices such as:

  • iPad®
  • GPS
  • E-Readers
  • Bluetooth®
  • iPhone®
  • iPod®
  • Game Systems
  • Mobile Phones
  • Blackberry
  • Tablets
  • Headsets
  • Digital Cameras

APPLICATION

  • Cafes
  • Labs
  • Office
  • Restaurants
  • Bedroom
  • Hotels
  • Salons
  • Kitchens
  • School
  • Libraries
  • Meeting Rooms
  • Workstations
  • Airport Lounges

SPECIFICATION

Receptacle Rating 15 Amp or 20 Amp, 125V AC
USB Rating 2.1Amp/3.0Amp/3.6Amp/4.0Amp,5V DC
Wiring Gauge #14 – #12 AWG
Operating Temperature -4 to 104℉(-20 to 40℃)
Dimension 4.17×1.69×1.65″ (106x43x42mm)
WARNINGS AND CAUTIONS
  • To be installed and used in accordance with appropriate code and regulations.
  •  If you are not sure about any part of these instructions, consult an electrician.
  • To be used with Class 2 connectors with interconnecting cables. The Class 2 USB ports are not intended for use with appliances and supporting products.
  • All connected Class 2 output cables must be routed away from the receptacle slots or any plug / cord inserted into the receptacle.
  • Use this device with copper or copper clad wire only.

INSTALLATION

  1. WARNINGS AND CAUTIONS: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!AVERTISSEMENTS ET MISES EN GARDE: POUR ÉVITER TOUT INCENDIE, TOUT CHOC OU LA MORT, COUPEZ LE DISJONCTEUR OU LE FUSIBLE ET TESTEZ QUE L’ALIMENTATION EST COUPÉE AVANT LE CÂBLAGE!

  2. This device is to be installed in a wall box measuring at least 3″ x 2″ x 2-1/2″ (standard single gang electrical wall box) and wired in accordance with NEC article 314 box fill requirements.

  3. Connect wires per WIRING DIAGRAM as follows:
    NOTE: Back and side wire terminals accept #14-#12 AWG copper or copper clad wires.

    • To Side Wire (if more than one wire is required on a terminal, you cannot side wire and must use the backwire option): Remove insulation from each circuit conductor per strip gage on device [approx. 4/5″ (20mm)]. Loop wires clockwise 3/4 turn around terminal screws. FIRMLY tighten screws over wire loop with the torque force among 14-16 in-lbf.
    • To Back Wire: Remove insulation from each circuit conductor [approx. 3/5″ (15 mm)]. Insert straight wires under clamps next to appropriate terminal screws. Tighten screws FIRMLY with the torque force among 14-16 in-lbf.
  4. Mount device in wall box with screws provided and mount wall plate.

  5. Restore power at circuit breaker or fuse. Installation is complete.

WIRING DIAGRAM

ELE GROUP CO., LTD
NO.158 CHUANGYUAN ROAD,
SIP SUZHOU, JIANGSU,
CHINA 215125 WWW.ELEGRP.COM