Eaton Wiring Devices TR7765W-BOX Combination 3.6A USB Charger User Manual
- June 5, 2024
- Eaton Wiring Devices
Table of Contents
Eaton Wiring Devices TR7765W-BOX Combination 3.6A USB Charger
Combination Receptacle / USB Charger
APPLICABLE MODEL NUMBER
- R1615S21
- R1615S30
- R1615S36
- R1615S40
- R1615D21
- R1615D30
- R1615D36
- R1615D40
- R1620D21
- R1620D30
- R1620D36
- R1620D40
FEATURES
- The Receptacle provide two 5V DC powered USB ports with a total of 2.1/3.0/3.6/4.0A charging current.
- Charge most compatible electrical device directly without an adapter.
- If the devices combined power requirements exceed the power capacity of the USB ports, the charger will shut down to protect your electrical devices.
- Replace a standard single or duplex receptacle.
- Compatible with USB 2.0/3.0 devices. The USB ports are used to charge portable electronic devices ONLY (NO data transfer capability).
- Back and side wire for easy installation.
COMPATIBILITY
The USB charger is compatible with USB powered devices such as:
- iPad®
- GPS
- E-Readers
- Bluetooth®
- iPhone®
- iPod®
- Game Systems
- Mobile Phones
- Blackberry
- Tablets
- Headsets
- Digital Cameras
APPLICATION
- Cafes
- Labs
- Office
- Restaurants
- Bedroom
- Hotels
- Salons
- Kitchens
- School
- Libraries
- Meeting Rooms
- Workstations
- Airport Lounges
SPECIFICATION
Receptacle Rating | 15 Amp or 20 Amp, 125V AC |
---|---|
USB Rating | 2.1Amp/3.0Amp/3.6Amp/4.0Amp,5V DC |
Wiring Gauge | #14 – #12 AWG |
Operating Temperature | -4 to 104℉(-20 to 40℃) |
Dimension | 4.17×1.69×1.65″ (106x43x42mm) |
WARNINGS AND CAUTIONS
- To be installed and used in accordance with appropriate code and regulations.
- If you are not sure about any part of these instructions, consult an electrician.
- To be used with Class 2 connectors with interconnecting cables. The Class 2 USB ports are not intended for use with appliances and supporting products.
- All connected Class 2 output cables must be routed away from the receptacle slots or any plug / cord inserted into the receptacle.
- Use this device with copper or copper clad wire only.
INSTALLATION
-
WARNINGS AND CAUTIONS: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!AVERTISSEMENTS ET MISES EN GARDE: POUR ÉVITER TOUT INCENDIE, TOUT CHOC OU LA MORT, COUPEZ LE DISJONCTEUR OU LE FUSIBLE ET TESTEZ QUE L’ALIMENTATION EST COUPÉE AVANT LE CÂBLAGE!
-
This device is to be installed in a wall box measuring at least 3″ x 2″ x 2-1/2″ (standard single gang electrical wall box) and wired in accordance with NEC article 314 box fill requirements.
-
Connect wires per WIRING DIAGRAM as follows:
NOTE: Back and side wire terminals accept #14-#12 AWG copper or copper clad wires.- To Side Wire (if more than one wire is required on a terminal, you cannot side wire and must use the backwire option): Remove insulation from each circuit conductor per strip gage on device [approx. 4/5″ (20mm)]. Loop wires clockwise 3/4 turn around terminal screws. FIRMLY tighten screws over wire loop with the torque force among 14-16 in-lbf.
- To Back Wire: Remove insulation from each circuit conductor [approx. 3/5″ (15 mm)]. Insert straight wires under clamps next to appropriate terminal screws. Tighten screws FIRMLY with the torque force among 14-16 in-lbf.
-
Mount device in wall box with screws provided and mount wall plate.
-
Restore power at circuit breaker or fuse. Installation is complete.