SKS 11660 airkompressor 10.0 floor pump User Manual
- June 5, 2024
- SKS
Table of Contents
11660 airkompressor 10.0 floor pump
User Manual
Exchange gauge floor pumps
-
Loosen the union nut on the pressure gauge cap.
-
Pull up the pressure gauge cap.
-
Unscrew the pressure gauge at the bottom with an Allen key (size 10).
-
Insert a new pressure gauge into the pressure gauge holder.
-
Screw on the pressure gauge with a maximum torque of 2 Nm.
-
Push the pressure gauge cap down again and secure it with the union nut.
Exchange rubber sealing cuff floor pumps
-
Remove the two Torx screws (T25) of the hose holder. Pull the cylinder rod out of the tube with a strong jerk.
-
Remove the old cup seal. If necessary, use a tool to do this (e.g. screwdriver).
-
Place the new cap over the cylinder rod until it is positioned in the designated joint.
CAUTION: Make sure that it is on the correct side!
-
Grease the rubber cup seal, re-insert the cylinder rod and screw it in.
Exchange recovery system
-
Loosen the union nut on the pressure gauge cap.
-
Pull up the pressure gauge cap.
-
Unscrew the pressure gauge at the bottom with an Allen key (size 10).
-
Turn the pressure gauge holder approximately 45° anti-clockwise until you feel the resistance. Then pull out the pressure gauge holder.
-
Replace the non-return valve system and follow the steps mentioned above in reverse order.
-
ATTENTION: Please make sure that the non-return valve system is correctly positioned in the designated fixing. Check that the spring is fitted securely!
Exchange valve seals
-
Remove cross-headed screws.
-
Remove the cap and seals.
-
Insert new seals.
ATTENTION: Different seals for Schrader and Presta.
-
Replace the cap and screw it tight.