FCC Compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Ondas Networks could void the user’s authority to operate the equipment.

FCC Exposure Statement
This equipment complies with the FCC RF radiation exposure limits set forth for a controlled environment. This transmitter must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must be at least 31 meters from the user and must not be co-located or operating in conjunction with any other antenna or transmitter.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Ondas Networks may void the user’s authority to operate the equipment.

System Overview

The Venus platform employs Ondas Networks’ FullMAX technology FullMAX is a multi‐cell, Point‐to‐Multipoint (PtMP) broadband wireless system based on the IEEE 802.16 standard with modifications to enable its operation in a wide range of frequencies and a wide range of channel sizes. The system is used to establish a private, broadband wireless service for mission critical industries. It supports both fixed and mobile applications. The main characteristics of the FullMAX System include the following: FullMAX employs HD-FDD or TDD framing to provide greater flexibility and to maximize spectrum utilization. FullMAX is capable of operating in any frequency band between 40 MHz and 6 GHz and in any channel size between 12.5 kHz and 5 MHz. FullMAX can be configured to operate in a downlink to uplink ratio to support symmetrical, asymmetrical and reverse asymmetrical applications.
The FullMAX system offers the private system operator wide area coverage by leveraging the following:

  • High transmit power from both the Base Station and Remote Stations
  • Exceptional receiver sensitivity
  • Superior propagation due to the operation in narrower channel sizes and low band frequencies

The FullMAX system offers excellent frequency utilization through the following capabilities:

  • Adaptive Modulation and Coding per link in both the downlink and uplink
  • Optimization of the downlink and uplink ratio for the user’s main applications. For example, in the case of SCADA applications, the FullMAX frame is configured as reverse asymmetrical, i.e., more bandwidth is allocated to the uplink than to the downlink.
  • Modifications to the standard air interface protocol to minimize MAC layer overhead.
  • Employ Band-AMC subcarrier allocation scheme in both uplink and downlink direction to maximize the percentage of data transport subcarriers.
  • Packet Header Suppression (PHS) with the following characteristics:
    • Compressible header field values are learned automatically with no need for manual configurations.
    • Support for multiple compressible values for the same header fields. As a result, PHS can be used even when the header fields are not constant.

FullMAX includes a versatile set of Quality of Service (QoS) tools that can optimize traffic performance for each application and prioritize access to the available bandwidth according to the operator’s requirements. QoS tools include various scheduling methods (e.g., Best Efforts and Unsolicited Grant Service), service flows with various QoS parameters such as priority level, minimum and maximum traffic rates, guaranteed delay, jitter, etc.

FullMAX provides secure connections with strong encryption (AES‐128 or AES-256), strong authentication(EAP after RSA with X.509 certificates) and advanced key management protocol (PKMv2). FullMAX supports various frequency reuse methods including:

  • Traditional full channel based frequency reuse
  • OFDMA based Band-AMC sub‐channel reuse with up to 12 sub-channels in both uplink and downlink. Any combination of sub-channels can be used in each sector in both downlink and uplink.
  • FullMAX Remote Stations support a pre‐configured channel acquisition plan, i.e., a preconfigured list of channel alternatives, characterized by center frequency, bandwidth, sub-channels and other parameters. During channel acquisition, the Remote Station goes through the list and evaluates the best alternative.
  • FullMAX has an advanced remote management system that enables the system operator to monitor, configure, manage, detect failures and diagnose problems. The FullMAX system configuration and FullMAX system provisioning support centralized management profiles. The FullMAX system architecture consists of Base Stations, Fixed Remote Stations and Mobile Stations.
  • Backhaul networking equipment connects the Base Stations to the customer’s Network Operations Center (NOC) and the FullMAX Network Management System (NMS).
  • FullMAX Base Stations are typically installed in the existing Private Land Mobile Radio (PLMR) towers serving their respective cells.
  • The FullMAX Base Station is designed as a single sector device. Any number of sectors can be designed per tower, however the most common configuration is a three sector design with one Base Station unit per sector.
  • The sector configuration dictates the type of antenna that should be used. Typically a router is used at the tower to connect all Base Stations to the NOC via backhaul facilities. FullMAX Fixed Remote and Mobile Stations are deployed throughout the tower’s serving area.

Physical Installation

Introduction
A Venus radio is comprised of software and hardware which is packaged in an indoor enclosure intended for mounting in a standard 19” rack.

Venus Enclosure
Specifications

Enclosure Material Aluminum Alloy
Dimensions (W x D x H) 8.5” x 4.85” x 2.95”

(216mm x 123mm x 75mm)

Operating Temperature| -40° F to 158° F

(-40° C to 70° C)

DC Input Power Range| 18 to 60 VDC
Power Consumption| No load : 13.1 watts @ 48 VDC Peak load : 23.4 watts @ 48 VDC

Product Overview

ONDAS X27VNB22G1 Venus Base Station FIG
1

Connection Descriptions

Connector Application
GPS Antenna SMA female connector for optional GPS antenna.
RF Out 50Ω N-Type female connector for RF input from antenna via external

bandpass filter
DC Input| DC power input 18 to 60 volts. Warning: Ensure Correct Polarity
Ethernet| 2 x RJ45 connector for Ethernet 10/100 Base-T interface
Console (Serial)| RJ45 8-pin connector wired using the Cisco interface specification for console access
Serial Data| RJ45 8-pin connector wired using the Cisco interface specification for serial data
Ground Post| Connection to building ground

Mounting Guidelines
A mounting bracket is provided for attaching the Venus enclosure to a vertical flat surface.ONDAS X27VNB22G1 Venus Base Station FIG 2