sako SUNPAX-5500W 5.5KW Hybrid Inverter User Manual
- June 5, 2024
- sako
Table of Contents
- sako SUNPAX-5500W 5.5KW Hybrid Inverter
- ABOUT THIS MANUAL
- SAFETY INSTRUCTIONS
- INTRODUCTION
- Features
- Product Overview
- INSTALLATION
- Mounting the Unit
- Battery Connection
- AC Input/Output Connection
- PV Connection
- Final Assembly
- Communication Connection
- OPERATION
- LCD Setting
- Parallel function operation instructions
- Fault Reference Code
- Warning Indicator
- TROUBLESHOOTING
- SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
sako SUNPAX-5500W 5.5KW Hybrid Inverter
ABOUT THIS MANUAL
Purpose
This manual describes the assembly, installation, operation and
troubleshooting of this unit. Please read this manual carefully before
installations and operations. Keep this manual for future reference.
Scope
This manual provides safety and installation guidelines as well as information
on tools and wiring.
SAFETY INSTRUCTIONS
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
- CAUTION –To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It’s very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanently grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
INTRODUCTION
This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display of fers user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications. There are two different types of built-in solar chargers: PWM and MPPT solar charger. For the detailed product specification, please consult your local dealers.
Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible to mains voltage or generator power
- Auto restart while AC is recovering
- Overload/ Over temperature/ short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
Basic System Architecture
The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:
- Generator or Utility.
- PV modules
Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube lights, fans, refrigerators and air conditioners.
One detection device needs be connected between the PV + and PV- & the ground, to ensure leakage current between PV + and PV- & the ground is less than 30mA. Isolation transformer Specs. : 1 0KW-220:220V 60*10 0 single phase Isolation transformer.
Product Overview
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- Circuit breaker
- USB communication port
- RS-232 communication port
INSTALLATION
Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the
package is damaged. You should have received the following items inside of
package:
- The unit x 1
- User manual x 1
- Communication cable x 1
Preparation
Before connecting all wirings, please take off bottom cover by removing two
screws as shown below.
Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
- The ambient temperature should be between O’C and 55’C to ensure optimal operation.
- The recommended installation position is to have adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
Install the unit by screwing two screws. It’s recommended to use M4 or M5 screws.
Battery Connection
CAUTION:
For safety operation and regulation compliance, it’s requested to install a
separate DC over-current protector or disconnect device between battery and
inverter. It may not be requested to have a disconnect device in some
applications, however, it’s still requested to have over-current protection
installed. Please refer to typical amperage in below table as required fuse or
breaker size.
WARNING!
All wiring must be performed by qualified personnel.
WARNING!
It’s very important for system safety and efficient operation to use
appropriate cable for battery connection. To reduce risk of injury, please use
the proper recommended cable as below. Recommended battery cable size:
Please follow below steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver
WARNING: Shock Hazard
Installation must be performed with care due to high battery voltage in
series.
CAUTION!!
Before making the final DC connection or closing DC breaker/ disconnector, be
sure positive(+) must be connected to positive(+) and negative (-) must be
connected to negative(-).
AC Input/Output Connection
CAUTION
Before connecting to AC input power source, please install a separate AC
breaker between inverter and AC input power source. This will ensure the
inverter can be securely disconnected during maintenance and fully protected
from over current of AC input. The recommended spec of AC breaker is 50A for
5.5KW.
CAUTION!! There
are two terminal blocks with “IN” and “OUT” markings. Please do NOT misconnect
input and output connectors.
WARNING!
All wiring must be performed by qualified personnel.
WARNING!
It’s very important for system safety and efficient operation to use
appropriate cable for AC input connection. To reduce risk of injury, please
use the proper recommended cable size as below.
Suggested cable requirement for AC wires
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase Land neutral conductor N 3 mm.
- For 5.5KW models, insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor first.
- Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor first.
- Make sure the wires are securely connected.
CAUTION:
Appliances such as air conditioners are required at least 2~3 minutes to
restart because it’s required to have enough time to balance refrigerant gas
inside of circuits. If a power shortage occurs and recovers in a short time,
it will cause damage to your connected appliances. To prevent this kind of
damage, please check manufacturer of air conditioner if it’s equipped with
time-delay function before installation. Otherwise, this inverter/charger will
trigger overload fault and cut off output to protect your appliance but
sometimes it still causes internal damage to the air conditioner.
PV Connection
CAUTION:
Before connecting to PV modules, please install separately a DC circuit
breaker between inverter and PV modules.
WARNING!
It’s very important for system safety and efficient operation to use
appropriate cable for PV module connection. To reduce risk of injury, please
use the proper recommended cable size as below.
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voe) of PV modules does not exceed max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voe) of PV modules should be higher than min. battery voltage.
Take 250Wp PV module as an example. After considering above two parameters, the recommended module configurations for 5.5KWare listed as below table.
Final Assembly
After connecting all wirings, please put bottom cover back by screwing two screws as shown below.
Communication Connection
Please use supplied communication cable to connect to inverter and PC. Insert bundled CD into a computer and follow on-screen instructions to install the monitoring software. For the detailed software operation, please check user manual of software inside of CD.
OPERATION
Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit.
Operation and Display Panel
The operation and display panel, shown in below chart, is on the front panel
of the inverter. It includes three indicators, four function keys and a LCD
display, indicating the operating status and input/output power information.
LCD Setting
After pressing ENTER butto the unit will enter setting mode. Press “UP” or ”DOWN” button to select setting programs. And then, press ”ENTER” button to confirm the selection or ESC button to exit
Parallel function operation instructions
( Maximum of nine parallel machines )
Single phase parallel:
-
CAUTION: It is forbidden for inverters to share the same solar panel group.
-
Connecting the parallel communication line and power cable as shown below
Warning: All inverters must share the same battery pack when paralleling. -
Set the parameters of each inverter separately (working mode, single-phase parallel function). Warning: When working in parallel, the working mode of each inverter must be the same working mode, output voltage.frequency.
-
After setting the parameters, tum on each inverter in turn.
WRINGING: for each group of PV, only one inverter can be connected, otherwise, it may damage inverters.
Two inverters in parallel: Power Connection:
Three-phase parallel:
-
CAUTION: It is forbidden for inverters to share the same solar panel group,
-
Connecting the parallel communication line and power cable as shown below
Warning: All inverters must share the same battery pack when paralleling -
Set the parameters of each inverter independently (working mode, single-phase parallel function, threephase parallel function and set NBIC phase sequence).
Warning: When working in parallel, the working mode of each inverter must be the same working mode. -
After setting the parameters, first turn on the A phase inverter and then turn on each inverter in turn. One inverter in each phase:
WRINGING: Do not connect the current sharing cable between the inverters which are in different phases, Otherwise, it may damage inverters.
Fault Reference Code
Fault code | Fault event |
---|
01
02
| Bus voltage is too high
Inverter voltage is too high
03| Inverter voltage is too low
04| Bus soft start failure
05| Overload fault
06| Output short-circuited
07| Battery voltage is too low
08| Inverter soft start failure
09| Bus voltage is too low
10| Parallel fault
11| Over temperature
12| Battery voltage is too high
13| A phase lost
14| B phase lost
15| C phase lost
16| AC output voltage and frequency setting is different
17| AC input voltage and frequency detected different
18| Power feedback protection
19| Firmware version inconsistent
20| Current sharing fault
23| PV is over current
24| PV over temperature
Warning Indicator
Warning code | Warning Event |
---|---|
01 | Battery voltage is too low |
02 | Input voltage is too low |
03 | Input voltage is too high |
04 | Overload |
05 | Over temperature |
06 | Fan is locked when inverter is on |
07 | Battery voltage is too high |
21 | PV voltage is too low |
22 | PV voltage is too high |
TROUBLESHOOTING
Problem
| ****
LCD/LED/Buzzer
| ****
Possible cause
| ****
What to do
---|---|---|---
Unit shuts down automatically during start-up process
| ****
LCD/LED and buzzer will be active then complete off
| ****
The battery voltage is too low
| ****
1. Re-charge battery.
12. Replace battery
No response after power on
| ****
No indication
| ****
1. The battery voltage is too low.
2. Internal fuse tripped
| ****
1. Contact repair
!Center for replacing the fuse.
12. Re-charge battery.
13. Replace battery.
Mains exist but the unit works in battery mode
| ****
Input voltage is displayed as ‘O’ on the LCD and green LED is flashing
| ****
Input protector is triggered
| ****
heck if ACbreaker is turned on and AC
r–,,iring is connected r–,,ell.
LED is flashing
| | ****
1. Check if AC wires are too thin and/or too
long.
Insufficient quality of AC power| 12-Check if generator
(if applied) is working r–,, ell or if input voltage range setting is incorrect
When the unit is turned on, internal relay is switched on and off repeatedly
| ****
LCD display and LED flashing
| ****
Battery is disconnected
| ****
!Check if battery wires are connected well
Buzzer beeps continuously and red LED is on
| warning code 06| Fan fault| Replace the fan
warning code 05
| ****
h Internal temperature of inverter component is over 85°C
| ****
check whether the environment around he equipment well ventilated
warning code 07
| ****
The battery voltage is too high u
| ****
!Check if spec sanctity of batteries are meet requirements
Battery is over-charged| Return to repair center
Buzzer beeps continuously and red LED
is on
|
fault code 13/14/15
|
Phase loss
| 1. check whether three-phase power is connected
2. check whether the inverter turns on three-phase parallel
---|---|---|---
| | Check whether the output voltage and frequency of each inverter are set
the
same
fault code 16| fC output voltage and frequency setting is different
Fault code 17
|
C input voltage and frequency detected different
| Check whether the input voltage and frequency of
each inverter are set the same
|
| | 1. restart the inverter. 2. check if UN cables are not Connected
reversely in all inverters.
3. for parallel system in single phase, make sure the sharing are connected in all inverters. To supporting three-phase system. make sure the sharing Cables are connected in the inverters in the same phase.
Fault code 18| Power feedback protection
|
[And disconnected in the
| inverters in different phase.
Fault code 19
|
Firmware version inconsistent
| 1. update all inverter firmware to the same version
2. if the problem
remains, please contact your installer.
SPECIFICATIONS
Table 1 Solar Mode specifications
MODEL
|
5.5KVA 48VDC
---|---
Rated output power
|
5.5KVA/5.5KW
PV Max power
|
5500W
PV operating voltage range|
120-450VDC
PV normal operating voltage
|
280-360VDC
Normal output voltage| 230VAC
Output voltage range| 230 ± 5%VAC
Normal output current| 24A
Power factor| 1.0
Efficiency(DC/AC)| e!:92%
Frequency| 50/60Hz
Overload protection
| MPPT will close immediately as long as the input power is greater than the
maximum output power
PV Max input current| 20A
Table 2 Line Mode specifications
Input Voltage Waveform
|
Pure sine wave (utility or generator)
---|---
Normal Input Voltage
|
230VAC
Low Loss Voltage
|
120VAC±7V ( wide range) 170VAC±7V(narrow range)
Low Loss Return Voltage
|
130VAC±7V ( wide range) 180VAC±7V(narrow range)
High Loss Voltage
|
280VAC±7V
High Loss Return Voltage
|
270VAC±7V
Max AC Input Voltage
|
300VAC
Normal Input Frequency
|
50Hz / 60Hz (Auto detection)
Low loss Frequency
|
40±1Hz
Low loss Return Frequency| 42±1Hz
High loss Frequency| 70±1Hz
High loss Return Frequency|
69±1Hz
Output short circuit protection| Circuit Breaker
Efficiency (Line Mode)|
95% ( Rated R load, battery full charged )
Communication| USB or RS232 or WIFI
Humidity| 0-90% RH( No-condensing)
Operation temperature|
-10-50°C
Table 3 Charge Mode specifications
Table 4 Inverter Mode specifications
Normal DC voltage | 48V |
---|---|
Waveform | Pure sine wave |
Output voltage range | 230VAC±5% |
Output frequency | 50/60Hz±1Hz |
Peak Efficiency | .:90% |
Power factor | 1.0 |
Overload protection
| 20s@101%-120% load ,10s@121%-150% load, 5s@.:150% load
Transfer time| 1Oms typical (UPS); 20ms typical (Appliances)
Protection features
| Low voltage protection; High voltage protection Overload protection ; Over- temperature protection
Short circuit protection; Over-charge protection; Battery reverse protection
Cold start voltage| 46.0VDC
Low voltage alarm(optional)| 36.0-50.0VDC
Low voltage alarm recovery| 44.0VDC
Low voltage shutdown(optional)|
36.0-50.0VDC
High voltage alarm recovery| 60.0VDC
Dimension( LxWxH)mm| 498X313X123
Net Weight (KG)|
10.0
Gross Weight (KG)|
11.3