Remote Controller Specifications
Model| RG10F(D)/BGEF, RG10F1(D)/BGEF, RG10F2(D1)/BGEFU1,
RG10F3(D1)/BGEFU1,RG10F(E)/BGEF, RG10F1(E)/BGEF, RG10F2(E1)/BGEFU1,
RG10F3(E1)/BGEFU1, RG10F(F/G/H/S)/BGEF, RG10F1(F/G/H)/BGEF,
RG10F2(F1/G1/H1)/BGEFU1, RG10F3(F1G1/H1)/BGEFU1
---|---
Rated Voltage| 3.0V( Dry batteries R03/LR03×2)
Signal Receiving Range| 8m
Environment| -5°C~60°C(23°F~140°F)
Quick Start Guide
NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions
sections of this manual for a detailed description of how to use your air
conditioner.
SPECIAL NOTE
- Button designs on your unit may differ slightly from the example shown.
- If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
- When there are wide differences between “Remote controller Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL
- The remote control must be used within 8 meters of the unit.
- The unit will beep when remote signal is received.
- Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
- Remove batteries if the remote will not be used more than 2 months.
NOTES FOR USING REMOTE CONTROL
The device could comply with the local national regulations.
-
In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
-
In USA, this device complies with part 15 of the
FCC Rules. Operation is subject to the following two conditions:- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
Buttons and Functions
Before you begin using your new air conditioner, make sure to familiarize
yourself with its remote control. The following is a brief introduction to the
remote control itself. For instructions on how to operate your air
conditioner, refer to the How to Use Basic Functions section of this manual.
NOTE: Press SET button to select the operation functions in the following
order:
Fresh( ) → AP mode( ) →
The selected symbol will flash on the display area, press the OK button to
confirm.
Fresh feature is not available for models of RG10F(D)/BGEF, RG10F(E)/BGEF and
RG10F(F/G/H/S)/BGEF.
NOTE: Press SET button to select the operation functions in the
following order:
Fresh( ) → I Sense ( ) → AP mode( ) → Fresh…
The selected symbol will flash on the display area, press the OK button to confirm.
Fresh feature is not available for models of RG10F2(D1)/BGEFU1, RG10F2(E1)/BGEFU1 and RG10F2(F1/G1/H1)/BGEFU1.
ON/OFF
Turns the unit on or off.
TEMP ∧
Increases temperature in 1 C(1 F) increments. Max. temperature is 30 C(86 F).
TEMP ∨
Decreases temperature in 1 C(1 F) increments. Max. temperature is 17 C(62 F).
FAN SPEED
Selects fan speeds in the following order:
AUTO → LOW → MED → HIGH
NOTE: Holding this button down for 2 seconds will activate Silence
feature(some units).
TIMER ON
Sets timer to turn unit on (see How to Use Basic Functions for instructions).
MODE
Scrolls through operation modes as follows:
AUTO → COOL → DRY → HEAT → FAN
NOTE: HEAT mode is not supported by the cooling only appliance.
SHORTCUT
Used to restore the current settings or resume previous settings.
OK
Used to confirm the selected functions.
SWING
Starts and stops the horizontal louver movement. Hold down for 2 seconds to
initiate vertical louver auto swing feature(some units).
TIMER OFF
Sets timer to turn unit off (see How to Use Basic Functions for instructions).
I SENSE
Temperature sensing and room temperature display button.
SLEEP
Saves energy during sleeping hours.
LED
Turns indoor unit’s LED display and air condiioner buzzer(some units) on and
off , which create a comfortable and quiet environment.
°C/°F
Press this button will alternate the temperature display between the °C & °F.
LOCK
Press together the two buttons simultaneously for 5 seconds to lock the
keyboard. Press together the two buttons for 2 seconds to unlock the keyboard.
Remote Screen Indicators
Information are displayed when the remote controller is power up.
FAN SPEED display
Displays selected fan speed:
LOW
MED
HIGH
AUTO
This fan speed can not be adjusted in AUTO or DRY mode.
Temperature/Timer/Fan speed display
Displays the set temperature by default, or fan speed or timer setting when
using TIMER ON/OFF functions.
- Temperature range: o o 17-30 C/62-86 F
- Timer setting range: 0-24 hours
This display is blank when operating in FAN mode.
Note:
All indicators shown in the figure are for the purpose of clear presentation.
But during the actual operation, only the relative function signs are shown on
the display window.
How to Use Basic Functions
ATTENTION Before operation, please ensure the unit is plugged in and power is available.
AUTO Mode
NOTE:
- In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
- In AUTO mode, fan speed can not be set.
COOL or HEAT Mode
NOTE: As outdoor temperature drops, the performance of your unit’s HEAT
function may be affected.
In such instances, we recommend using this air conditioner in conjunction with
other heating appliances.
DRY Mode
NOTE: In DRY mode, fan speed can not be set since it has already been automatically controlled.
FAN Mode
NOTE: In FAN mode, you can’t set the temperature. As a result , no temperature displays in remote screen.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically
turn on/off.
TIMER ON setting
Press TIMER ON button to initiate the ON time sequence.
Press Temp. up or down button for for multiple times to set the desired time
to turn on the unit.
Point remote to unit and wait 1sec, the TIMER ON will be activated.
TIMER OFF setting
Press TIMER OFF button to initiate the OFF time sequence.
Press Temp. up or down button for for multiple times to set the desired time
to turn off the unit
Point remote to unit and wait 1sec, the TIMER OFF will be activated.
NOTE:
- When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
- Cancel either function by setting its timer to 0.0h.
TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours
after the current time.
Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.
How to Use Advanced Functions
Swing function
Press Swing button
The horizontal louver will swing up and down automatically when pressing Swing
button.
Press again to make it stop
Keep pressing this button more than 2 seconds, the vertical louver swing function is activated. (Model dependent)
LED DISPLAY
Press this button to turn on and turn off the display on the indoor unit.
Keep pressing this button more than 5 seconds, the indoor unit will display
the actual room temperature. Press more than 5 seconds again will revert back
to display the setting temperature.
FP function
The unit will operate at high fan speed (while compressor on) with temperature automatically set to 8 C/46 F.
Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting temperature of 17 C/62 F to activate FP function.
Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel this function.
SHORTCUT function
Press SHORTCUT button(some units)
Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).
If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated ).
SLEEP function
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. The sleep function is not available in Fan or Dry mode.Please refer to the OWNER’S MANUAL for more details.
SET function
- Press the SET button to enter the function setting, then press SET button or TEMP ∨ or TEMP ∧ button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm.
- To cancel the selected function, just perform the same procedures as above.
- Press the SET button to scroll through operation functions as follows: Fresh ( ) I Sense ( ) AP mode( )
*[]:** If your remote controller has I Sense button, you can not use the SET button to select the I sense feature.
FRESH function( ) (some units) :
When the FRESH function is initiated, the ion generator is energized and will
help to purify the air in the room.
AP function( )(some units) :
Choose AP mode to do wireless network configuration. For some units, it
doesn’t work by pressing the SET button. To enter the AP mode, continuously
press the LED button seven times in 10 seconds.
I Sense function( ):
The I Sense function enables the remote control to measure the temperature at
its current location and send this signal to the air conditioner every 3
minutes interval.
When using AUTO, COOL or HEAT modes, measuring ambient temperature from the
remote control(instead of from the indoor unit itself) will enable the air
conditioner to optimize the temperature around you and ensure maximum comfort.
NOTE: Press and hold I Sense button for seven seconds to start/stop memory feature of I Sense function. For the remote controls without I Sense button, press and hold SLEEP button for seven seconds to start/stop the memory feature of I Sense function.
- If the memory feature is activated, On displays for 3 seconds on the screen.
- If the memory feature is stopped, OF displays for 3 seconds on the screen.
- While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the I Sense function.
Read User Manual Online (PDF format)