Altronix T1KE34V Trove Kisi Kits Installation Guide

June 14, 2024
Altronix

Altronix Logo More than just power.™

Access & Power Integration
Altronix/Kisi Kits
Installation Guide

Models Include:

T1KE34V
4 Door Kit with Fused Outputs
Fully assembled kit includes:
– Trove1 enclosure with TLU1 backplane
– One (1) AL600XB220 – Power Supply/Charger
– One (1) ACM4 – Fused Access Power Controller| T1KE34DV
4 Door Kit with PTC Outputs
Fully assembled kit includes:
– Trove1 enclosure with TLU1 backplane
– One (1) AL600XB220 – Power Supply/Charger
– One (1) ACM4CB – PTC Access Power Controller
---|---
T1KE38V
8 Door Kit with Fused Outputs
Fully assembled kit includes:
– Trove1 enclosure with TLU1 backplane
– One (1) AL600XB220 – Power Supply/Charger
– Two (2) ACM4 – Fused Access Power Controllers| T1KE38DV
8 Door Kit with PTC Outputs
Fully assembled kit includes:
– Trove1 enclosure with TLU1 backplane
– One (1) AL600XB220 – Power Supply/Charger
– Two (2) ACM4CB – PTC Access Power Controllers
T2KE3316V
16 Door Kit with Fused Outputs
Fully assembled kit includes:
– Trove2 enclosure with TLU2 backplane
– Two (2) AL600XB220 – Power Supply/Charger
– Two (2) ACM8 – Fused Access Power Controllers| T2KE3316DV
16 Door Kit with PTC Outputs
Fully assembled kit includes:
– Trove2 enclosure with TLU2 backplane
– Two (2) AL600XB220 – Power Supply/Charger
– Two (2) ACM8CB – PTC Access Power Controllers

All registered trademarks are property of their respective owners.
Rev. 122221
Installing Company: …………………….. Service Rep. Name: ……………………..
Address: …………………….. Phone #: ……………………..

Overview:

Altronix Trove Kisi kits are pre-assembled and consist of Trove1LU1 or Trove2LU2 enclosure/backplane with factory installed Altronix power supply/charger(s) and sub-assemblies. Trove Kisi kits also accommodates up to four (4) Kisi Pro Controllers for up to sixteen (16) doors in a single enclosure.

Configuration Chart:

Altronix Model Number| 220VAC
60Hz Input
Current (A)| Power Supply Board Input Fuse
Rating| Maximum Supply Current for Main Output on Power Supply board(s) and ACM4/ACM8 Access Power Controllers’ outputs| Nominal  DC
Output Voltage Range
(VDC)| Fail-Safe/
Fail-Secure
Outputs| ACM4(CB)/
ACM8(CB) Board Input Fuse Rating| ACM4/ ACM8
Board Output
Fuse Rating| ACM4CB/
ACM8CB
Board Output PTC
Rating
---|---|---|---|---|---|---|---|---
T1KE34V| 1.5| 5A/ 250V| 24VDC @ 5.7A| 20.17-26.4| 4| 10A/32V| 3A/32V| –
T1KE34DV| –| 2.5A
T1 KE38V| 8| 10A/32V| 3A/32V| –
T1 KE38DV| –| 2.5A
T2KE3316V| 16| 10A/250V| 3.5A/250V| –
T2KE3316DV| –| 2.5A

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.

  1. Remove backplane from enclosure. Do not discard hardware.

  2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws, level and secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and install the two/three fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the two/three lower screws and make sure to tighten all screws refer to pages 6-7.

  3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure, approximately 2” from the right side (Fig. 1, pg. 2).
    Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.

  4. Mount Kisi Pro Controllers to TLU1 or TLU2 backplane, refer to pages 3-5.

  5. Refer to the XBV Power Supply/Charger Installation Guide for AL600XB220 and corresponding Sub-Assembly Installation Guides for ACM4(CB) and ACM8(CB) for further installation instructions.

Hardware:

Spacer 5/16” Pan Head Screw Mounting Magnet

T1KE34V and T1KE34DV: Configuration of Kisi Pro Controllers:

  1. Fasten mounting magnets (provided) to Kisi Pro Controllers with screws and spacers (provided) using the controllers’ mounting holes (Fig. 2, pg. 3).

  2. Attach mounting magnets to TLU1 in the approximate position as shown below (Fig. 2a, pg. 3).
    Note: Kisi Pro Controllers should be properly oriented.
    Please make sure that they are mounted correctly, as shown in Fig. 2 below.

  3. Fasten TLU1 backplane to Trove1 enclosure utilizing hardware (provided).

Access Controller Position Chart for the Following Models:

Kisi Pem Mounting
Pro Controller

Altronix T1KE34V Trove Kisi Kits - Controller

T1KE38V and T1KE38DV: Configuration of Kisi Pro Controllers:

  1. Fasten mounting magnets (provided) to Kisi Pro Controllers with screws and spacers (provided) using the controllers’ mounting holes (Fig. 3, pg. 4).

  2. Attach mounting magnets to TLU1 in the approximate position as shown below (Fig. 3a, pg. 4).
    Note: Kisi Pro Controllers should be properly oriented.
    Please make sure that they are mounted correctly, as shown in Fig. 3 below.

  3. Fasten TLU1 backplane to Trove1 enclosure utilizing hardware (provided).

Access Controller Position Chart for the Following Models:

Kisi Pem Mounting
Pro Controller

Altronix T1KE34V Trove Kisi Kits - Configuration

T2KE3316V and T2KE3316DV: Configuration of Kisi Pro Controllers:

  1. Fasten mounting magnets (provided) to Kisi Pro Controllers with screws and spacers (provided) using the controllers’ mounting holes (Fig. 4, pg. 5).

  2. Attach mounting magnets to TLU2 in the approximate position as shown below (Fig. 4a, pg. 5).
    Note: Kisi Pro Controllers should be properly oriented.
    Please make sure that they are mounted correctly, as shown in Fig. 4 below.

  3. Fasten TLU2 backplane to Trove2 enclosure utilizing hardware (provided).

Access Controller Position Chart for the Following Models:

Altronix T1KE34V Trove Kisi Kits - Configuration 2

T1KE34(D)V and T1KE38(D)V Enclosure Dimensions (H x W x D approximate) : 18” x 14.5” x 4.625” (457mm x 368mm x 118mm)

Altronix T1KE34V Trove Kisi Kits - Dimensions

T2KE3316(D)V Enclosure Dimensions (H x W x D approximate) : 27.25” x 21.5” x 6.5” (692.2mm x 552.5mm x 165.1mm)

Altronix T1KE34V Trove Kisi Kits - Dimensions 2

Notes:

Altronix is not responsible for any typographical errors.

Altronix Logo140 58th Street, Brooklyn, New York 11220 USA
phone: 718-567-8181
fax: 718-567-9056
web site: www.altronix.com
e-mail: info@altronix.com
Lifetime Warranty.
IITrove KE XBV Kits
K17V
Trove KE XBV Kits Installation Guide

Documents / Resources

| Altronix T1KE34V Trove Kisi Kits [pdf] Installation Guide
T1KE34V, T1KE38V, T2KE3316V, T1KE34DV, T1KE38DV, T2KE3316DV, T1KE34V Trove Kisi Kits, Trove Kisi Kits, Kisi Kits, Kits
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals