enlighted SU5I Desk Occupancy Sensor Installation Guide
- June 5, 2024
- enlighted
Table of Contents
enlighted SU5I Desk Occupancy Sensor
Shipped Components
- Surface Sensor, USB, (SU-5i-USB)
- One VHB adhesive strip
Optional Components
Mount bracket with fwo #4 0.5″ wood screws, (BRKT-SU5-50)
items you may Need
- USB-A to micro USB-B or micro USB-A connector cable up to 8m or 26.2 feet in length
- AC/DC 5V with 10W or 3W external wall mounted power adapfer
- Cable clips with strong adhesive tape
Tools you may Need
- Hand screwdriver
- 50-pack of the brackets with screws sold separately with the
- optional mount bracket.
Caution
- Installation and maintenance must with local, state, and national electrical codes (NEC) and requirements.
- Installing sensors in the ceiling may require running cable through walls or ceilings. One end of the cable connects fo fhe USB port of the sensor, and
- The offered info a power adaptor. Make your cable selection based on the type of installation.
Overview
The Surface Sensor can be installed either in the ceiling or placed under the desk. The Surface sensors are shipped with the adhesive strip. The mounting bracket must be ordered separarely. The sensors can be installed using Adhesive strip, or
Wood screws
The adhesive strip is recommended for a metal ceilinggrid or any smooth tile surface. Since desks can be ofwood or metal, use either adhesive strip or woodSCrews fo mount the sensor fo the underside o tne desk.
Guidelines
Center and mount the sensor to the underside of the least 5″ from thc esk and ar least 5 from the rear edge for a typical 27″ height seated desk, or a 42-50″ height standing desk. Mount the sensor parallel to the front edge of the desk. After installation, the sensor lens must be facing the desk occupant for the sensor to detect occupancy. Ensure that the USB cable is long enough to plug into the nearest USB adaptor.
Using Adhesive Strip (for Ceiling and Desk)
- Step 1: Use a dry clean cloth or paper fowel to clean the surface to ensure a strong bond.
- Step 2: Remove the plastic strip on the double-sided adhesive strip and fix it to the back of the sensor..
- Step 3: For ceiling applications, remove the mask over the lens. Hold the top edge of the dome-shaped mask, rotate it counterclockwise, and lift the mask.
- Step 4: Peel the backing from the other side of the adhesive.
- Step 5: For ceilings, hold the sensor firmly for five seconds to ensure proper adhesion to the surface. For desks, hold the sensor such that the USB port is facing the rear of the desk, and the sensor lens is facing the desk occupant. Then, firmly press the sensor into the underside of the desk.
- Step 6: Allow at least 30 minutes for the mount to adhere to the surface
Using Wood Screws (for Desk)
- Step 1: Insert the wood screws through the mounting holes with the tab facing the front edge of the desk. Fasten the mount to the underside of the desk using a screwdriver.
- Step 2: When placing the sensor inside the mount, hold the sensor with the USB port facing the rear of the desk.
- Step 3: Place the sensor by guiding the grooves in the base onto fhe hooks on the mount. Slide the sensor back until you hear a click to secure it to the mount.
Wiring the Cable to the Power Supply
Connect the USB end of the sensor cable into the micro USB port on the sensor, and the other end to a powered USB external adaptor plugged into the wall.Confirm that the green LED is on solid. A red solid or blinking LED indicates a faulty sensor or wiring issue. To keep cables organized, use a cble holder with cord clips for holding the extra length of the cable. Ceiling sensors can use up to 8m extended cable.
Removing the Sensor
- If you have used adhesive tape, peel off the tape by pulling up each corner and peeling it to the center. Youcan try rubbing some alcohol into the adhesive to loosen it if it is too sticky. Gently remove the sensor from the desk.
- If you have used wood screws, insert a flat-head screwdriver between the tab on the mount and the sensor. Press the tab up and gently remove the sensor by sliding it forward and down from the mount.
LED DESCRIPTION
FCC and Industry Canada Compliance Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant fo part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual may cause harmful interference fo radio communications. Operation of this equipment in a residential areais likely to cause harmful interference in which case the user will be required to corect the interference at his own expense. This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following three conditions: this device may not cause harmful interference, AND The device must accept any interference received, including interference that may cause undesired operation. The equipment complies with FCC radiation exposure limits set torth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body. Changes or modifications not expressly approved by Enlighted lnc. could void the user’s authority to operate the equipment.
CE
This device complies with the essential requirements and other relevant requirements of the R&TTE Directive (1999/5/EC) and Radio Equipment Directive (RED) 2014/53/EU. The equipment is Class I radio equipment which can be placed on the market and be put into service without restrictions in accordance with article 1(3) of Commission Decision 2000/299/EC (Version July 2014).
- Wireless protocol: IEEE802.15.4, Radio Freg: 2400-2483.5MHz
- RF TX Output power (max): 3dBm
- Wireless protocol: IEEE802.15.1, Radio Freq: 2400-2483.5MHz,
- RF TX Output power (max): 3dBm
- Company Contact Information
- Location: 930 Benecia Ave, Sunnyvale, CA 94085
- Phone:+1.650.964.1094
- Web: enlightedinc.com
Technical Support
For questions, contact support@enlightedinc.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>