MBJ SAL-0910 Arealight Series LED Light User Manual

June 5, 2024
MBJ

MBJ SAL-0910 Arealight Series LED Light User Manual
MBJ SAL-0910 Arealight Series LED Light

Model Sizes in Series

The illumination is available in the following sizes 1)

SAL-0910| SAL-0920| SAL-0930

Possible LED Colors

LED Abbr. 1) Peak Wavelength 2)
White -WT 5000K, min. CRI80
Red -RD near 625 nm
Infrared -IR near 850 nm
Green -GN near 525 nm
Blue -BE near 465 nm
Yellow -YE near 580 nm
  1. Color option will be added to the model name after the size information.
    SAL-0920-RD referrs to a arealight with 625 nm red light.

  2. This is an approximated value. The exact value also depends on LED temperature and LED current.

Safety Notes

Before working with this unit, read the warning and application instructions carefully and completely before operating the device.
Warning icon
Warning icon

  1. The device is designed for indoor use only.
  2. Light – Due to the risk of flash burn of the eyes it is not recommended to look directly into the light source. The lighting must be switched off before installation and/or maintenance. The device must not be used when a failure may cause a personal injury.
  3. Heat – In case of insufficient heat dissipation or when running the light in flash mode with a too high duty cycle, the surface temperature may exceed 60 °C. Keep off flammable materials at any time.
  4. Electricity – The housing is electrically isolated from the ground of the power supply. Exceeding the permissible input voltage Uin or ULED(+) can lead to the destruction of the device or to a significant shortening of the lifetime of the LEDs in the device.
  5. Usage – Please prevent mechanical stress to the light surface during operation. This will lead to an inhomogeneous light emission.
  6. Cleaning – The light emission surface has to be cleaned with a standard glass cleaner and a soft cleaning cloth. Do not use other materiel for cleaning as it will damage the device.

Manual Arealight Series: 23. May 2022

MBJ Imaging GmbH

Jochim-Klindt-Straße 7
+49 4102 778 90 31
22926 Ahrensburg, Germany
sales@mbj-imaging.com
www.mbj-imaging.com

Mechanical Integration

The light is equipped with several combined mounting positions of M4 threaded holes. It can be used to fix the lighting to the specified position. In addition M2.5 threaded holes are provided at the two long sides to mount the foil and filter holder set. To secure a long live time additional heat transfer measurements at the holding postions is highly recommended.
Manual Arealight Series: 23. May 2022

Example: Model SAL-0920

More 2D and 3D drawings can be found online: www.mbj-imaging.com

Mechanical Integration Mechanical
Integration

Specification SAL-0910 SAL-0920 SAL-0930
Operating temperature 10°C to 30°C
Certifications CE, RoHS
Degree of protection IP54
Humidity 30 % to 70 %

Electrical Connection

The lighting is equipped with an 4 pin M8x1 connector.

Electrical Connection

Pin Color 1) Standard (-s) Direct (-x) 2)
1 brown 24 VDC LED (+)
2 white Dim LED (+)
3 blue Trigger LED (-)
4 black Ground LED (-)
  1. Wire color of MBJ lighting cable.
  2. Connection to 24VDC without external LED controller may destroy the unit.

Additional Information

Pin 3 (Trigger) is an ‘active high’ input signal with 5…24V=ON and 0…1V=OFF, it is a high resistance current sink with 0.2mA for 5V and 5mA for 24V Pin 2 (DIM) is used as brightness control and operation mode switch, it is a high resistance current sink with 0.2mA for 5V and 1mA for 24V. For the connection it is recommended to use the MBJ lighting cable with a maximum length of 10m.

Integrated Controller (-s)

Supported operation modes with the integrated LED controller

Pin 2 (Dim) Operation mode
24V steady light 1)
1…10V steady light with brightness control 2)
24V triggered light
GND triggered flash light with max. 20 ms and up-to 100 % more light

intensity 3)

  1. Pin 3 (Trigger) needs permanent 24V to activate steady light mode.
  2. PWM with 3.8 kHz clock is used, recommended minimal camera exposure is 5ms.
  3. Latency between trigger and LED light ON is about 20…30µs, the maximum recommended clock speed is 1 kHz, the maximum recommended duty cycle is 25% and the minimum recommended flash time is 100µs.

Specifications

Specification SAL-0910 SAL-0920 SAL-0930
Optical parameter
Luminous area (A x B) or (ID^/OD) 90 mm x 100 mm 90 mm x 200 mm 90 mm x 300

mm
Light emission| Areal, rectangular light field with direct light emission
Recommended use| Commonly used for brightfield applications, large objects or need for bright areal illumination, e.g. print inspection.
Different lighting angles highlight varied surface characteristics.
Recommended light working distance| 10 mm – 400 mm| 10 mm – 550 mm| 10 mm – 700 mm
Luminous Flux of white LEDs 1)| 2760 lm| 5520 lm| 8280 lm
Radiant Power of red LEDs 1)| 8120 mW| 16240 mW| 24360 mW
Radiant Power of IR LEDs 1)| 3910 mW| 7820 mW| 11730 mW
Electrical parameter|
Available interfaces| -s with integrated LED Controller and 4 operation modes; -x with direct LED access (external LED control is required)
Uin for -s Version| 24V DC +/- 5 %
ULed(+) range for -x version 2)| WT / BE / YE: 17 … 20 VDC; GN: 20 … 23 VDC; RD: 12 … 15 VDC; IR: 9 … 12 VDC
Typical Power (-s version)|
Steady light operation (white / red / IR)3)| 17 W / 13 W / 14 W| 34 W / 26 W / 42 W| 51 W / 39 W / 42 W
During ON time at flashed light operation 4)| 46 W| 92 W| 112 W
Recommended LED current (-x version)| | |
Steady light (100% duty cycle)| 900 mA
(1350 mA for IR)| 1800 mA
(2700 mA for IR)| 2700 mA
(4050 mA for IR)
Flash light (50 % duty cycle, 500 ms pulse)| 1800 mA
(1350 mA for IR)| 3600 mA
(2700 mA for IR)| 5400 mA
(4050 mA for IR)
Flash light (25 % duty cycle, 50 ms pulse)| 2700 mA
(1350 mA for IR)| 5400 mA
(2700mA for IR)| 8100 mA
(4050 mA for IR)
Flash light (10 % duty cycle, 5 ms pulse)| 3600 mA
(2700 mA for IR)| 7200 mA
(5400 mA for IR)| 10800 mA
(8100 mA for IR)
General parameter|
Dimension (H x W x D)| 99 mm x 110 mm x 23 mm| 99 mm x 210 mm x 23 mm| 99 mm x 310 mm x 23 mm
Weight| 370 g| 760 g| 1155 g
Material| Anodized aluminum housing with PMMA light cover
Connector| M8x1 socket, 4 pin, male (for pinning details refer to chart “Electrical Connection”)
Accessories| For cable, foil holder brackets, light manipulation foils and external LED controller: please check www.mbj-imaging.com

  1. Values are approximate with a +/- 7% tolerance
  2. Lower voltage value refers to steady light, higher voltage value refers to flash light, please see max. allowed current in the row below.
  3. Power for Blue / Yellow is comparable to White, Power for Green is approx. 1,2 times higher 4) Triggered flash light with max. 20ms and up to 100% more light intensity, calculated for White.

Application Samples for (-s) controller

Application Samples for \(-s\) controller Application Samples for \(-s\)
controller Application Samples for \(-s\) controller Application Samples for \(-s\)
controller

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals