Model Sizes in Series

  1. Size definition: High Power WBL-0420 refers to a wide bar with a light field of 45 mm x 200 mm, High Power SRL-12 refers to a ring light with a outside light field diameter of 121 mm, Narrow/Wide refers to the light beam opening angle.

Possible LED Colors

  1. Color option will be added to the model name after the size information. High Power WBL-0420-RD refers to a backlight with 634 nm red light.
  2. This is an approximated value. The exact value also depends on LED temperature and LED current.

Mechanical Integration

The light is equipped with M4 threaded holes at each end. It can be used to fix the lighting to the specified position. In addition M2.5 threaded holes are provided at the two long sides to mount the foil and filter holder set.

Spot: The spot is equipped with 1x M8 and 3x M4 threaded holes at one side to fix the lighting to a specified position.

To ensure a long operational live time of the light additional heat transfer measures at the mounting positions are highly recommended.

Example: Model High Power WBL-0420

More 2D and 3D drawings can be found online: www.mbj-imaging.com

  1. Max. of 30°C is recommended for steady light operation w/o additional heat transfer measurements, for max. 45°C a thermal connection is mandatory. Max. of 45°C is also permissible for flash light operation with a max. 10 % duty cycle.

  2. MBJ LED lights are protected against the ingress of solids and water in accordance with the selected protection class and applicable standards. Permanent protection against liquids containing solvents, such as cleaning agents, machine emulsions or other lubricants, cannot be guaranteed. IP is only valid with a connected cable (MBJ cable recommended). High Power Spotlights are not available as IP67.

Safety Notes

Before working with this unit, read the warning and application instructions carefully and completely before operating the device.

1. The device is designed for indoor use only.

2. Light ­- Due to the risk of flash burn of the eyes it is not recommended to look directly into the light source. The lighting must be switched off before installation and/or maintenance. The device must not be used when a failure may cause a personal injury.

3. Heat -­ In case of insufficient heat dissipation or when running the light in flash mode with a too high duty cycle, the surface temperature may exceed 60 °C. Keep off flammable materials at any time.

4. Electricity ­- The housing is electrically isolated from the ground of the power supply. Exceeding the permissible input voltage Uin or ULED(+) can lead to the destruction of the device or to a significant shortening of the lifetime of the LEDs in the device.

5. Usage -­ Please prevent mechanical stress to the light surface during operation. This will lead to an inhomogeneous light emission.

6. Cleaning ­- The light emission surface has to be cleaned with a standard glass cleaner and a soft cleaning cloth. Do not use other material for cleaning as it will damage the device.

03200.07 Manual MBJ High Power HP-Series, März 2023

MBJ Imaging GmbH

Jochim-Klindt-Straße 7
+49 4102 778 90 – 31
22926 Ahrensburg, Germany
sales@mbj-imaging.com
www.mbj-imaging.com

Electrical Connection

The lighting is equipped with an 5 pin M12x1 connector.

  1. Wire color of MBJ lighting cable
  2. Connection to 24 VDC without external LED controller may destroy the unit

Additional Information:

Pin 3 (Trigger) is an `active high’ input signal with 5…24 V=ON and 0…1 V=OFF, it is a high resistance current sink with 0.2 mA for 5 V and 5 mA for 24 V

Pin 2 (DIM) is used as brightness control and operation mode switch, it is a high resistance current sink with 0.2 mA for 5 V and 1 mA for 24 V.

For the connection it is recommended to use the MBJ lighting cable with a maximum length of 10 m.

Integrated Controller (-s)

Supported operation modes with the integrated LED controller

  1. Pin 3 (Trigger) needs permanent 24 V to activate steady light mode.
  2. PWM with 3.8 kHz clock is used, recommended minimal camera exposure is 5 ms.
  3. Latency between trigger and LED light ON is about 20…30 µs, the maximum recommended clock speed is 1 kHz, the maximum recommended duty cycle is 25 % and the minimum recommended flash time is 100 µs.

Application Samples for (-s) controller

  1. Values are approximate with a +/- 7 % tolerance
  2. Lower voltage value refers to steady light, higher voltage value refers to flash light, please see max. allowed current in the rows below.
  3. Power for Blue / Yellow is comparable to White, Power for Green is approx. 1,2 times higher
  4. Triggered flash light with max. 20 ms and up to 100 % more light intensity, calculated for White.