TRANE R2 Multi-Zone Heat Pump Air-Source Recovery User Guide
- June 5, 2024
- Trane
Table of Contents
TRANE R2 Multi-Zone Heat Pump Air-Source Recovery User Guide
System Reference Guide
CITY MULTI® R2-Series (Heat Recovery)
- TURY (Air-Source)
- TQRY (Water-Source)
- Targeted for use in commercial applications
- Provides simultaneous cooling and heating through a branch circuit (BC) controller
- Capacity: 6–32 tons
- Three-Phase Power
- Connect up to 50 indoor units with 50–150% connected capacity allowed.
Note: Branch circuit controller required.
CITY MULTI® Y-Series (Heat Pump)
- TUHY (Air-Source).
- TQHY (Water-Source).
- Targeted for use in commercial applications.
- All indoor units operate in the same mode.
- Capacity: 6–36 tons.
- Three-Phase Power.
- Connect up to 50 indoor units with 50–130% connected capacity allowed.
SMART MULTI
- MSM (Heat Pump)
- MSH (Hyper-heat)
- Capacity: 3–5 tons
- Single-Phase Power
- Targeted for use in light commercial or large-scale residential applications
- All indoor units operate in the same mode
- H2i® models: 3 and 4 ton capacities
- Connect up to 12 indoor units with 50–130% connected capacity allowed
Nv-Series
- NTX (Heat Pump)
- NTY (Cooling Only)
- NTXM (Multi-Zone Heat Pump)
- Targeted for use in residential applications
- Capacity: 0.75–5 tons
- Single-Phase Power
- Range from 1-to-1 systems to multi-zone systems with up to 8 zones
Note: Simultaneous cooling & heating is not available with NTXM Branch Box systems.
P-Series
- TRUZ (Heat Pump)
- TRUY (Cooling Only)
- Targeted for use in residential and light commercial applications with 24/7 cooling requirements
- Capacity: 1–3.5 tons
- Single-Phase Power
- Designed for 1-to-1 installations
CITY MULTI® System Reference Guide Outdoor Unit Model Number Reference
Guide
T: Brand Name
T = Trane
U: Configuration
U = Air Cooled
Q = Water Cooled
R: Unit Type
R = Heat Recovery
H = Heat Pump
M = Single-Phase HP
Y: Compressor Drive
Y = Inverter Compressor
P: Performance
P = Standard Efficiency
E = High Efficiency
H = Hyper-Heat
168: Capacity (BTU/H)
- 072 = 72,000
- 096 = 96,000
- 120 = 120,000
- 144 = 144,000
- 168 = 168,000
- 192 = 192,000
- 216 = 216,000
- 240 = 240,000
- 264 = 264,000
- 288 = 288,000
- 312 = 312,000
- 336 = 336,000
- 360 = 360,000
- 384 = 384,000
- 408 = 408,000
- 432 = 432,000
3: Voltage
3 = 208/230V/3P/60Hz
4 = 460V/3P/60Hz
1 = 208/230V/1P/60Hz
A: Module Size
A = Single
B = Double
C = Triple
N: Generation Code
N = 9th Generation
4: Refrigerant
4 = R410a
0: Major Change
0 = 1st Generation
1 = 2nd Generation
2 = 3rd Generation
A: Minor Change
A = 1st Generation
B = 2nd Generation
N: Coil Coating
N = Standard (No Coating)
B = BS Salt Protection
Nv-Series Model Reference Guide
N: Family
N = Nv-Series
T: Brand Name
T = Trane
X: Function/Type
X = Heat Pump (INVERTER)
V = Indoor Matched with
Various Outdoor
Y = Cooling Only (INVERTER)
S: Unit Configuration
Outdoor:
S = Single-Zone Outdoor
M = Multi-Zone Outdoor
Indoor:
A = Convertible Air Handler
C = Cassette 2’ x 2’
D = Horizontal-Ducted
F = Floor Unit
U = EZ FIT® Ceiling Cassette
W = Wall-Mounted
PH: Series
EL = Entry Level
KH = Non-Highwall Hyper-Heat
KS = Non-Highwall Series
SM = SMART MULTI Heat Pump
MT = Mid Tier
MX = Standard Multi-Zone
PH = Hyper-heat
ST = Standard Line
SH = Standard Line SMART MULTI Hyper-Heat
PB = Hyper-heat with Base Heater
PF = Hyper-heat for Floor Standing
12: Capacity (BTU/H)
BTU/H (X 1,000)
06 = 6,000
09 = 9,000
12 = 12,000
15 = 15,000
18 = 18,000
24 = 24,000
30 = 30,000
36 = 36,000
42 = 42,000
48 = 48,000
60 = 60,000
A: Chassis Generation
A, B, C
1: UL/Non-UL
1 = US / UL Rated
2 = Non US/
Non-UL Rated
1: Max Number of Zones
1 = Single-Zone
2+ = Multi-Zone
2: Voltage
1 = 115V, 1ph
2 = 208/230V,1ph
A: Major Change
(Compressor, software, related to features/performance etc)
*: Minor Service Change
(Parts change, no function/spec change)
Designed for residential applications. User-friendly zoned cooling and heating solutions for single- or multi-room applications or the whole home. Hyper-Heat INVERTER-driven outdoor units can provide high heating performance at lower ambient temperatures. Many ENERGY STAR® certified models.
P-Series Model Reference Guide: Indoor Unit
T: Brand Name
T = Trane
P: Family
P = P-Series
KA0A: Indoor Description
KA0A = Wall-Mounted
CA0A = Ceiling-Suspended
LA0A = Ceiling Cassette
VA0A = Air Handler
EADA = Horizontal-Ducted
012: Capacity (BTU/H)
012 = 12,000
018 = 18,000
024 = 24,000
030 = 30,000
036 = 36,000
042 = 42,000
1: Voltage
1 = 208/230V,1ph
0 = 115V, 1ph
K: Chassis Generation
A: Control Type
7: Generation Code
0: Future Use
A: Minor Design Update
A = 1st Generation
B = 2nd Generation
P-Series Model Reference Guide: Outdoor Unit
TR: Brand Name
TR = Trane
U: Configuration
U = Single Outdoor Unit
Z: Unit Type
Z = Heat Pump
Y = Cooling Only
A: Heating
A = Standard
H = Hyper-Heat
012: Capacity (BTU/H)
012 = 12,000
018 = 18,000
024 = 24,000
030 = 30,000
036 = 36,000
042 = 42,000
1: Voltage
1 = 208/230V,1ph
0 = 115V, 1ph
L: Chassis Generation
A: Control Type
8: Generation Code
0: Future Use
N: Coil Coating
N = Standard No Coating
B = Seacoast Protection
A: Minor Design Update
A = 1st Generation
B = 2nd Generation
Designed for light commercial installations. Ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms. Hyper-Heating INVERTER® (H2i®) outdoor units can provide superior heating performance at lower ambient temperatures. Long lineset lengths. Outside air intake on TPLA, TPCA, TPEAD, and TPVA models. P-Series ducted units have higher static than most Nv-Series, allowing for design flexibility
SUPPORT
© 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
TR-CM-1595
5-22
Pinted in the U.S.A.
1340 Satellite Boulevard, Suwanee, GA 30024
Phone: 800-433-4822
Fax: 800-658-1458