velleman DVM852 DIGITAL MULTIMETER User Manual
- June 5, 2024
- Velleman
Table of Contents
- Introduction
- Used Symbols
- General Guidelines
- Maintenance
- During Use
- General Description
- Overvoltage/Installation Category
- Pollution Degree
- Specifications
- Voltage Measurement
- Current Measurement
- Resistance Measurement
- Diode Testing
- Continuity Testing
- Battery and Fuse Replacement
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DVM852
DIGITAL MULTIMETER – 1999 COUNTS
CAT. III 600 V
USER MANUAL
Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device
after its lifecycle could harm the environment. Do not dispose of the unit (or
batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling. This device should be returned to your distributor or
to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before
bringing this device into service. If the device was damaged in transit, do
not install or use it and contact your dealer.
Used Symbols
| AC (Alternating Current)
---|---
| DC (Direct Current)
| Both AC and DC
| Risk of Electric shock. A potentially hazardous voltage is possible.
| Caution: risk of danger, refer to the user manual for safety
information.
Warning: a hazardous condition or action that may result in injury or
death
Caution: condition or action that may result in damage to the meter or
equipment under test
| Double insulation (class 2-protection)
| Earth
| Fuse
| Capacitor
| Diode
| Continuity
General Guidelines
Refer to the V elleman® Service and Quality Warranty on the last pages of this manual.
| This symbol indicates: Read instructions
Not reading the instructions and manual can lead to damage, injury or death.
---|---
| This symbol indicates: Danger
A hazardous condition or action that may result in injury or death
| This symbol indicates: Risk of danger/damage
Risk of a hazardous condition or action that may result in damage, injury or
death
| This symbol indicates: Attention; important information
Ignoring this information can lead to hazardous situations.
| WARNING: To avoid electrical shock always disconnect the test leads
prior to pening the housing. To prevent fire hazards, only use fuses with the
same ratings s specified in this manual.
Remark: refer to the warning on the battery compartment
| Avoid cold, heat and large temperature fluctuations. When the unit is moved
from a cold to a warm location, leave it switched off until it has reached
room temperature. This to avoid condensation and measuring errors.
| Protect this device from shocks and abuse. Avoid brute force when operating.
| Pollution degree 2-device. For indoor use only. Keep this device away from
rain, moisture, splashing and dripping liquids. Not for industrial use.
Refer to §8 Pollution degree.
| Keep the device away from children and unauthorised users.
| Risk of electric shock during operation.
Be very careful when measuring live circuits.
| There are no user-serviceable parts inside the device.
Refer to an authorized dealer for service and/or spare parts.
| This is an installation category CAT III measuring instrument. Never use
this equipment in a CAT IV environment. Refer to §7 Overvoltage/installation
category.
---|---
| Read this addendum and the manual thoroughly.
Familiarise yourself with the functions of the device before actually using
it.
| All modifications of the device are forbidden for safety reasons.
Damage caused by user modifications to the device is not covered by the
warranty.
| Only use the device for its intended purpose. Using the device in an
unauthorized way will void the warranty. Damage caused by disregard of certain
guidelines in this manual is not covered by the warranty and the dealer will
not accept responsibility for any ensuing defects or problems.
Maintenance
There are no user-serviceable parts inside the device. Refer to an authorized dealer for service and/or spare parts. Before performing any maintenance activities, disconnect the test leads from the jacks. For instructions on replacing battery or fuse, refer to §11 Battery and fuse replacement. Do not apply abrasives or solvents to the meter. Use a damp cloth and mild detergent for cleaning purposes.
During Use
Risk of electric shock during operation.
Be very careful when measuring live circuits.
- Never exceed the limit value for protection. This limit value is listed separately in the specifications for each range of measurement.
- Do not touch unused terminals when the meter is linked to a circuit which is being tested.
- Never use the meter with CAT III installations when measuring voltages that might exceed the safety margin of 600 V above earth ground.
- Set the range selector at its highest position if the intensity of the charge to be measured is unknown beforehand.
- Disconnect the test leads from the tested circuit before rotating the range selector in order to change functions.
- When carrying out measurements on a TV set or switching power circuits, always remember that the meter may be damaged by any high amplitude voltage pulses at test points.
- Always be careful when working with voltages above 60 VDC or 30 VAC rms. Keep your fingers behind the probe barriers at all times during measurement.
- Never perform resistance, diode or continuity measurements on live circuits. Make sure all capacitors in the circuit are depleted.
General Description
The DVM852 is a battery-operated, hand-held 3 ½ digital multi-meter for
measuring DC and AC voltages, DC current and resistance. It also offers the
possibility of executing continuity tests and of testing diodes and
transistors. The back light is optional.
Refer to the illustration on page 2 of this manual:
-
Display
3 ½ digits, 7 segments, LCD: 15 mm high -
Back light
When this button is pushed, the backlight will illuminate your display for approximately 5 seconds. -
Rotary switch
This switch is used to select functions and desired ranges as well as to turn the meter on/off. -
Hold button
Upon pushing this button, the display will retain the last reading and the “ “-symbol will remain on the LCD until the button is pushed again. -
“10A” jack
Insert the red test lead in this connector in order to measure a max. current of 10 A. -
“COM” jack Insert the black (negative) test lead.
-
“VΩmA” jack
Insert the red (positive) test lead in this connector to measure voltage, resistance and current (except 10 A).
Overvoltage/Installation Category
DMMs are categorized depending on the risk and severity of transient overvoltage that might occur at the point of test. Transients are short-lived bursts of energy induced in a system, e.g. caused by lightning strike on a power line. The existing categories according EN 61010-1 are:
CAT I| A CAT I-rated meter is suitable for measurements on protected CAT I
electronic circuits that are not directly connected to mains power, e.g.
electronics circuits, control signals…
---|---
CAT II| A CAT II-rated meter is suitable for measurements in CAT Ienvironments
and mono-phase appliances that are connected to the mains by means of a plug
and circuits in a normal domestic environment, provided that the circuit is at
least 10 m apart from a CAT III- or 20 m apart from a CAT IV-environment. E.g.
household appliances, portable tools…
CAT III| A CAT III-rated meter is suitable for measurements in CAT I- and CAT
II-environments, as well as for measurements on (fixed) monoor poly-phased
appliances which are at least 10 m apart from of a CAT IV-environment, and for
measurements in or on distribution level equipment (fuse boxes, lighting
circuits, electric ovens).
CAT IV| A CAT IV-rated meter is suitable for measuring in CAT I-, CAT IIand
CAT III-environments as well as on the primary supply level. Note that for all
measurements on equipment for which the supply cables run outdoors (either
overhead or underground) a CAT IV meter must be used.
Warning: This device was designed in accordance with EN 61010-1 installation category CAT III 600 V. This implies that certain restrictions in use apply that are related to voltages and voltage peaks which can occur within the environment of use. Refer to the table above.
This device is only suitable for measurements up to 600 V in CAT III
Pollution Degree
IEC 61010-1 specifies different types of pollution environments, for which different protective measures are necessary to ensure safety. Harsher environments require more protection, and the protection against the pollution which is to be found in a certain environment depends mainly on the insulation and the enclosure properties. The pollution degree rating of the DVM indicates in which environment the device may be used.
Pollution degree 1| No pollution or only dry, nonconductive pollution occurs.
The pollution has no influence. (only to be found in hermetically sealed
enclosures)
---|---
Pollution degree 2| Only nonconductive pollution occurs. Occasionally,
temporary conductivity caused by condensation is to be expected.(home and
office environments fall under this category)
Pollution degree 3| Conductive pollution occurs, or dry nonconductive
pollution occurs that becomes conductive due to condensation that is to be
expected. (industrial environments and environments exposed to outside air –
but not in contact with precipitation)
Pollution degree 4| The pollution generates persistent conductivity caused by
conductive dust or by rain or snow. (exposed outdoor environments and
environments where high humidity levels or high concentrations of fine
particles occur)
Warning: This device was designed in accordance with EN 61010-1 pollution degree 2. This implies that certain restrictions in use apply that are related to pollution which can occur within the environment of use. Refer to the table above.
This device is only suitable for measurements in Pollution degree class 2 environments.
Specifications
This device is not calibrated when purchased! Regulations concerning
environment of use:
Use this meter only for measurements in CAT I, CAT II and CAT III environments
(see §7) Use this meter only in a pollution degree 2 environment (see §8)
Ideal working conditions include: temperature: 18 °C to 28 °C (64 °F to 82 °F)
relative humidity: max. 80 % altitude: max. 2000 m (6560 ft)
voltage ………………………………………………………………… 600 V
fuse protection …………………………… F250 mA/600 V, F10 A/600 V
power supply ……………………………… 1 x 9 V 6F22 alkaline battery
display…………………………………………………… LCD, 1999 counts
display dimensions …………………………………………… 45 x 18 mm
sampling rate………………………………………………………. 2-3/sec.
measuring method……………… dual-slope integration A/D converter
over-range ……………………………………………………………….. “1”
continuity buzzer …………………………………………………………yes
transistor test …………………………………………………………….yes
diode test………………………………………………………………….yes
low-battery indication ………………………………………………….. yes
ranging mode ………………………………………………………. manual
ranges ……………………………………………………………………… 19
data hold …………………………………………………………………. yes
backlight ………………………………………………………………….. yes
auto power-off ……………………………………………………………. no
dimensions …………………………………………….. 68 x 138 x 30 mm
weight (with battery) …………………………………………….. ± 170 g
storage temperature …………………………………….. -10 °C to 50 °C
test lead probe (incl.)………………… CAT III 600 V, 10 A; L = 80 cm
DC VOLTAGE
| Do not measure circuits that may contain voltages > 600 V
---|---
range| resolution| accuracy
2000 mV| 0.1 mV| ± (0.5 % rdg + 2 digits)
200 mV| 1 mV
20 V| 10 mV
200 V| 100 mV
600 V| 1 V| ± (0.8 % rdg + 2 digits)
Overload protection: 250 V rms for 200 mV range; 600 V DC or AC rms for all other ranges
AC VOLTAGE
| Do not measure circuits that may contain voltages > 600 V
---|---
range| resolution| accuracy
200 V| 100 mV| ± (1.2 % rdg + 10 digits)
600 V| 1 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40-400 Hz
Overload protection: 600 V DC or AC rms
DC CURRENT
| Do not measure circuits that may contain voltages > 600 V
---|---
range| resolution| accuracy
200 µA| 0.01 µA| ± (1.0 % rdg + 2 digits)
20 µA| 0.1 µA
2000 µA| 1 µA
20 mA| 10 µA
200 mA| 100 µA| ± (1.5 % rdg + 2 digits)
10 A| 10 mA| ± (3.0 % rdg + 2 digits)
Overload protection: F250 mV/600 V, F10 A/600 V fuse Note: 10 A up to 15 seconds every 10 minutes
RESISTANCE
| Do not conduct resistance measurements on live circuits
---|---
range| resolution| accuracy
200 Ω| 0.1 Ω| ± (0.8 % rdg + 3 digits)
2000 Ω| 1 Ω| ± (0.8 % rdg + 2 digits)
20k Ω| 10 Ω
200k Ω| 100 Ω
2000k Ω| 1k Ω| ± (1.0 % rdg + 2 digits)
Overload protection: F250 mV/600 V fuse
Maximum open-circuit voltage: 3.2 V
DIODE AND CONTINUITY
| Do not conduct diode or continuity measurements on live circuits
---|---
range| description
| if continuity exists (less than 40 W), built-in buzzer will sound
| displays the diode’s approx. forward voltage drop
Voltage Measurement
| Do not measure circuits that may contain voltages > 600 V
---|---
| Use extreme caution when measuring voltages higher than 60 VDC or 30 VAC
rms. Always place your fingers behind the protective edges of the test probes
while measuring!
DC VOLTAGE MEASUREMENT
- Connect the red test lead to the “VΩmA” jack and the black lead to the “COM” jack.
- Set the rotary switch in the desired V position. If the voltage to be measured is unknown beforehand, you should set the range switch in the highest range position and then reduce gradually until the ideal resolution is obtained.
- Connect the test leads to the source being measured.
- Read the voltage value on the LCD display along with the polarity of the red lead connection.
AC VOLTAGE MEASUREMENT
- Connect the red test lead to the “VmA” jack and the black test lead to the “COM” jack.
- Set the rotary switch in the appropriate V ~ position.
- Connect the test leads to the source to be measured.
- Read the voltage value on the LCD display.
Current Measurement
| Do not measure circuits that may contain voltages > 600 V
---|---
| Use extreme caution when measuring voltages higher than 60 VDC or 30 VAC
rms. Always place your fingers behind the protective edges of the test probes
while measuring!
- Connect the red test lead to the “VmA” jack and the black test lead to the “COM” jack (switch the red lead to the “10A” jack for measurements between 200 mA and 10 A).
- Set the rotary switch (DCA) in the desired position.
- Open the circuit in which the current is to be measured and connect the test leads to the circuit IN SERIES.
- Read the current value and the polarity of the red lead connection on the LCD display
Resistance Measurement
Do not conduct resistance measurements on live circuits. Make sure all capacitors in the circuit are depleted.
- Connect the red test lead to the “VmA” jack and the black test lead to the “COM” jack (the red lead has a positive polarity “+”).
- Set the rotary switch in the appropriate “” range position.
- Connect the test leads to the resistor to be measured and read the LCD display.
- If the resistance being measured is connected to a circuit, turn off the power and discharge all capacitors before applying the test probes.
Diode Testing
Do not conduct diode or continuity measurements on live circuits. Make sure all capacitors in the circuit are depleted.
- Connect the red test lead to “VΩmA” jack and the black one to the “COM” jack (the red lead has a positive polarity “+”.).
- Set the rotary switch in the “ ” position.
- Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approx. forward voltage drop of the diode will be displayed. If the connection is reversed, the display will merely show a “1”.
Continuity Testing
Do not conduct diode or continuity measurements on live circuits. Make sure all capacitors in the circuit are depleted.
- Connect the red test lead to “VΩmA” and the black one to “COM”.
- Set the range switch in the “ ” position.
- Connect the test leads to two points of the circuit to be tested. If continuity exists, the built-in buzzer will sound.
Battery and Fuse Replacement
| WARNING: To avoid electrical shock always disconnect the test leads
prior to opening the housing. To prevent fire hazards, only use fuses with the
same ratings as specified in this manual.
Remark: refer to the warning on the battery compartment
---|---
| There are no user-serviceable parts inside the device. Refer to an
authorized dealer for service and/or spare parts.
| Disconnect the test leads from the test points and remove the test
leads from the measuring terminals before replacing the batteries or fuses.
- When” ” is displayed, the battery should be replaced.
- Fuses rarely need replacement and blown fuses almost always result from human error.
To replace the battery or fuse:
- Switch of the meter
- Remove the protective edge, release the two screws located at the backside of the meter and gently open the housing.
- Remove the old battery and insert a new one.
Battery: 9 V 6LR61 alkaline, do not use rechargeable batteries and make
sure to respect the polarity
Fuses: F250 mA 600 V and F10 A 600 V 5 x 20 mm Make sure the meter is
closed tight and put the protective edge back in place before using the meter.
Troubleshooting
If the device beeps continuously while measuring continuity, this means that
the 600 V-250 mA internal fuse is defective. Replace this fuse. Keep in mind
that a low battery level could lead to incorrect measurements. Replace the 9 V
battery on a regular basis. (tip: the reduced luminosity of the backlight/LCD
display indicates a low battery level)
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulting from (incorrect) use of
this device. For more info concerning this product and the latest version of
this manual, please visit our website www.velleman.eu. The information in this
manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights
reserved. No part of this manual may be copied, reproduced, translated or
reduced to any electronic medium or otherwise without the prior written
consent of the copyright holder.
V. 01 29/03/2016
©Velleman nv
Made in PRC
Imported by Velleman nv
Legen Heirweg 33, 9890 Gavere, Belgium
www.velleman.eu
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>