WILDANGER TECHNIK 51551 Suction Pump Instruction Manual
- June 5, 2024
- WILDANGER TECHNIK
Table of Contents
WILDANGER TECHNIK 51551 Suction Pump
The information contained in this document may alter at any time without
previous notice. It is prohibited to copy or spread any parts of this document
in any way without prior written allowance. All rights reserved. The WilTec
Wildanger Technik GmbH cannot be held accountable for any possible mistakes in
this operating manual, nor in the diagrams and figures shown. Even though the
WilTec Wildanger Technik GmbH has undergone the biggest possible efforts to
ensure that the operating manual is complete, faultless, and up to date,
mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we
look forward to hearing from you.
Send an e-mail to: service@wiltec.info
or use our contact form: https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in
our online shop via: https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany
shortens the waiting time and allow for a rapid on-site transaction, we ask
you to call us previously or placing your order via the webshop.
- E-mail: service@wiltec.info
- Tel: +49 2403 55592–0
- Fax: +49 2403 55592–15
To return orders for exchange, repair, or other purposes, please use the following address. Attention! To allow for smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler
- E-mail: service@wiltec.info
- Tel: +49 2403 55592–0
- Fax: +49 2403 55592–15
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.
Safety instructions
CAUTION
This device can only be used in the vicinity of bodies of standing water,
garden ponds or swimming ponds, if connected to a fault current protection
switch with a triggering nominal current up to 30 mA (according to VDE 0100
Article 702 and 738). The device is not suitable for usage in swimming pools,
paddling pools, and other bodies of water, which might be used by people or
animals during operation. The device must not be used while sentient beings
are within the hazard area. In case of doubt contact a professional
electrician. This device can only be used by children or individuals with
reduced physical, sensory, or mental capabilities, or lack of experience and
knowledge, if they have received instructions concerning the use of the
appliance and are being supervised by a person familiar with the product and
responsible for their safety. Children should be always supervised to ensure
that they do not play with it.
ATTENTION
- Run a visual inspection of the device before every use. Do not use the device, if safety appliances are damaged or show signs of wear. Never ignore safety regulations.
- Only use the device for its intended purpose stated in this instruction manual.
- You are responsible for the safety within your working environment.
- The cable or plug must not be repaired in case of being visibly damaged and instead must be replaced with a new one by a qualified electrician.
- The voltage indicated on the type plate of the device corresponds to 230 V alternating voltage and must match the mains voltage on site.
- Never pull, lift, carry, or suspend the device by its power cable.
- Always ensure that the power plug and socket outlet are located within a flood-proof area and are protected from moisture
- Always disconnect the device from the main supply before performing repairs or maintenance work.
- Ensure that the device is not directly hit by streams of water.
- The owner of the device is responsible for its proper installation in accordance with the local installation and safety regulations. (Eventually, contact a qualified electrician)
- The user is responsible for taking the appropriate measures (such as the installation of alarm systems or standby pumps) to avoid consequential damage caused by flooding of rooms due to a malfunction of the device.
- The pump must never run dry or be used while its inlet port is closed completely. In case of the device runs dry, the manufacturer warranty will be voided.
- The device must not be connected to systems supplying drinking water.
- The device must not be used to operate swimming pools.
WARNING
Carefully read all the safety guidelines and instructions found in this
manual. Failure to comply with the rules safety rules and regulations may lead
to electric shock, fire, and/or serious damage and injuries. Always make sure
to properly store this instruction manual for future reference
Stability
- The maximum temperature of the conveyed liquid should not exceed +35 ℃ during permanent operation.
- The conveyance of flammable, gassing, or explosive liquids is forbidden.
- The conveyance of aggressive fluids (such as acids and bases), as well as abrasive liquids (such as sand), must be avoided to prevent the pump from being damaged.
- To prevent the pump from running dry, we recommend the use of one of our automatic pump control systems.
Intended use
Fields of application
- Watering green spaces, vegetable patches, and gardens
- Operation of lawn sprinklers.
- Withdrawal of water from ponds, freshwater streams, wells, rain barrels, and reservoirs, if used in combination with a pre-filter.
Pumping media
Only fresh water, rainwater, or mild suds may be pumped with this device.
Technical data
Article number | 51548/51550 | 51549/51551 |
---|---|---|
Energy supply | 220–240 V / 50 Hz | |
Power input (W) | 600 | 1200 |
Max. lifting head (m) | 35 | 48 |
Max. flow rate (ℓ⁄h) | 2800 | 3800 |
Max. suction lift (m) | 7 | 8 |
Noise level (dB (A)) | 81 | 84 |
Operation instructions
We generally recommend the use of a pre-filter as well as a suction set consisting of a suction hose, suction strainer, and check valve in order to optimize the operation and prevent the device from taking damage from stones and other foreign substances.
Layout
Causes | Solutions |
---|---|
Line voltage is missing | Check the power supply. |
Pump impeller jams – thermal controller has shut the device down | Dismantle |
and clean the pump.
The pump does not suck water in
Causes | Solutions |
---|---|
Suction valve is not inside the water | Place the suction valve into the water. |
No water inside the pump station | Fill water into pump intake nozzle. |
Air inside the suction line | Check suction line for leakages. |
Suction valve leaks | Clean suction valve. |
Suction strainer is clogged | Clean suction strainer. |
Max. suction head is exceeded | Check suction head. |
Insufficient flow rate
Causes | Solutions |
---|---|
The suction head is too high | Check suction head. |
The suction strainer is soiled | Clean suction strainer. |
The water level decreases rapidly | Put suction valve deeper into water. |
Pump capacity is reduced by pollutants | Clean pump and replace worn parts. |
The pump is shut down by the thermal controller
Causes | Solutions |
---|---|
Motor overloads – High friction due to foreign matter | Dismantle and clean |
pump, prevent suction of foreign matter with a filter.
References
- Aoyue.de
- Teichtip.de
- WilTec - Ihr Online Shop für Haus, Garten, Werkstatt, Freizeit
- Unternehmen: WilTec Wildanger Technik GmbH