KUSTOM SIGNALS ProLaser 4 Handheld LIDAR Police Speed Gun User Guide
- June 5, 2024
- KUSTOM SIGNALS
Table of Contents
ProLaser 4 Quick Reference Guide
RCMPĀ Configuration
ProLaser 4 Rear panel Controls and Display
Head-Up Display
ProLaser 4 Multi-function Button
| Single Press| Press and Hold
---|---|---
| Rear Display Brightness| Power On/Off
| HUD Brightness
(Poor Weather in Menu)| Poor Weather Mode
| Menu|
| Mode
Up (In Menu)| Receding Only Targets
| Volume
Down (In Menu)| Approaching Only Targets
| Display Lock
(Enter button in Menu)
Mark Select Events (Option)| Self-Test
First Time Operation
- Install 4-AA batteries in the Battery Compartment, or plug-in USB.
- Press and hold the power button to power on/off.
- Hold the unit by the handle and aim with the HUD with both eyes open.
- Press and hold the trigger to fire the laser.
- Place the aiming reticle on the target vehicle. Continue target tracking through the HUD.
- While holding the trigger down, Speed and Range continually update in the HUD and on the rear display.
- Audio tones provide targeting feedback. A solid tone indicates the target was successfully acquired.
- Release the trigger to lock the measurement in the HUD and rear panel display.
The ProLaser 4 will enter (default) sleep mode after two (2) minutes and will power down after 15 minutes. Sleep timers are user adjustable.
Recall Events (Option)
- Press the Menu button.
- Navigate to and select Events.
- Use the up/down buttons to scroll through up to 100 previous measurements on the rear panel.
- Each event will list the date, time, target direction, target speed, and target range when the target was locked.
Download Events Data (Option)
ProLaser 4 allows the user to download measurements over the USB to a spreadsheet using a PC utility. The utility may be downloaded from the Kustom website from the ProLaser 4 product and Service pages. The Events data includes Speed & Range measurements with date & time, units, tracking history time, and serial number as shown below.
Date | Time | Speed | Units | Range | Units | Track | Units | S/N |
---|---|---|---|---|---|---|---|---|
15/2/2022 | 12:39:41 | 120 | kmh | 150 | m | 3.6 | sec | 2155 |
15/2/2022 | 12:39:11 | 95 | kmh | 350 | m | 1.7 | sec | 2155 |
15/2/2022 | 12:38:47 | 88 | kmh | 150 | m | 15.1 | sec | 2155 |
15/2/2022 | 12:38:14 | 127 | kmh | 470 | m | 12 | sec | 2155 |
15/2/2022 | 12:37:48 | 94 | kmh | 480 | m | 0.7 | sec | 2155 |
15/2/2022 | 12:36:39 | 87 | kmh | 482 | m | 2.3 | sec | 2155 |
15/2/2022 | 12:36:16 | 115 | kmh | 120 | m | 5.9 | sec | 2155 |
15/2/2022 | 12:15:42 | 189 | kmh | 150 | m | 4.2 | sec | 2155 |
ProLaser 4 Menus
The menu button accesses the following settings or modes:
Distance| Sets min/max range limits to target vehicles for school and work
zone enforcement. Fire the LASER at the desired target or use up/down arrows
to enter values.
Press enter to set min/max ranges. Any target measured outside the range
limits will not be displayed.
---|---
Set Direction| Sets target direction discrimination to Approaching only,
Receding only, or Both.
DIF-TEST| Two-target, differential distance accuracy test mode.
Continuous/Single| Sets enforcement mode to continuous target measurement or
single-shot mode (option).
Units| Select between mph/km/h; mph/knots; or km/h/knots (option).
HUD Options| Toggle Range in HUD on/off. Select from four aiming reticles.
Events| Displays the last 100 locked targets with Speed, Range, and Direction
with the date and time stamp.
Set Time/Date| Set date and time in 24-hour format (option).
Stopwatch| Average speed over distance enforcement mode (option).
Accuracy Tests
Self-Test | Press the test button to run internal accuracy tests. |
---|---|
HUD Alignment Test | Place the ProLaser 4 in range mode. Select an isolated |
target ~100 feet away and sweep HUD horizontally and
vertically across the target. Listen for audio tone and verify aiming reticle
on target coincides with tone and range measurement in HUD.
Differential Distance Test| Select two targets ~ 50 and 100 feet away. Target
each when prompted and verify range accuracy.
(800)4KUSTOM
800-458-7866
www.kustomsignals.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>