LEO XKJ-1105S Portable Lawn Pump Owner’s Manual
- June 1, 2024
- LEO
Table of Contents
LEO XKJ-1105S Portable Lawn Pump
Specifications:
- Model: XKJ-1105S
- Property Voltage: 110-120V/60Hz
- Horse Power: 1-1/2HP
- Amps: 10A
- Max. Head: 150 ft.
- Max. Flow: 1200 GPH
- Discharge Size: 1 in.
- Power cord length: 6 ft.
Product Usage Instructions
Assembly and Safety Instructions:
- Read and understand all assembly and operation instructions before operating the pump.
- Ensure to call customer service at 833-290-1189 for any questions, problems, or missing parts.
- Do not run the pump without sufficient water to avoid damage and warranty void.
- Avoid pumping flammable or explosive liquids to prevent fire hazards.
- Always disconnect the pump from power before inspection and do not handle with wet hands.
Operational Guidelines:
- Use the pump with a 5/8 in. or larger inside diameter garden hose.
- Avoid continuous operation as a fountain or waterfall pump.
- The pump motor has an automatic thermal protector that turns off the pump if it overheats.
- Avoid overusing the thermal protector feature to prevent pump damage and warranty void.
Maintenance and Safety Cautions:
- Avoid touching the pump housing while in operation as it may be hot and cause burns.
- Avoid standing in water when the pump is connected to power.
- The pump is not designed for permanent installation.
FAQ :
-
Q: What should I do if my pump stops working suddenly?
A: Check if the thermal protector has turned off the pump due to overheating. Allow the pump to cool down before restarting. -
Q: Can I use this pump for continuous fountain operation?
A: No, it is not recommended to run the pump continuously as a fountain or waterfall pump. -
Q: What should I do if I encounter any issues with my pump?
A: Contact our customer service department at 833-290-1189 for assistance with any problems or questions regarding the product.
Distributed by
- INC 16649 W Hardy Rd, Houston, TX 77060
- Phone 833-290-1189 E
- E-mail: infous@leopump.com
OWNER’S MANUAL
- Portable lawn pump
- Model:XKJ-1105S
WARNING: Read carefully and understand all ASSEMBLY AND OPERATION
INSTRUCTIONS before operating. Failure to follow the safety rules and other
basic safety precautions may result in serious personal injury
If you have any QUESTIONS, PROBLEMS, MISSING PARTS, please call our customer
service department at 833-290-1189
before returning to your retailer
TECHNICAL SPECIFICATIONS
Property | Specifications |
---|---|
Voltage | 110-120V/60Hz |
Horse Power | 1-1/2HP |
Amps | 10A |
Max. Head (ft.) | 150 ft. |
Max. Flow (GPH) | 1200 |
Discharge Size (in.) | 1 in. |
Power cord length (ft.) | 6 ft. |
PERFORMANCE
Model | GPH of water @ Total Ft. Head | Max. Head |
---|---|---|
0 ft. | 50 ft. | 100 ft. |
XKJ-1105S | 1200 | 980 |
SAFETY INFORMATION
- Please read and understand this entire manual before attempting to assemble operates or install the product. If you have a y questions regarding the product, please call customer service at 1-888-538 0082.
WARNING:
- Running the pump without sufficient water will damage the pump and void the pump’s warranty.
- Do not pump flammable or explosive liquids such as oil gasoline kerosene ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury and/or death.
- Always disconnect the pump from its power source before inspection .
- Do not stand in water when the pump is connected. Do not handle pump with wet hands.
- Do not touch the pump housing while it is operating as the pump may be HOT and can cause serious skin burns.
- Do not disassemble the motor housing. This pump has NO repairable internal parts, and disassembling may cause dangerous electrical wiring issues.
CAUTION:
- This pump is made of high-strength corrosion-resistant materials. It will provide trouble-free service for many years when properly installed, maintained, and used. However, inadequate electrical power or blockage by dirt could cause damage to the pump and void the warranty. To minimize the potential for water damage due to pump failure please read the section of this manual regarding common pump problems and remedies or call one of our pump experts at 1-888-538-0082.
- This pump is not designed to function as a permanently installed pump. It is also not engineered to be run continuously as a “fountain” or “waterfall” pump. The pump should be used with a 5/8 in. or larger inside diameter garden hose.
- For safety, the pump motor has an automatically resetting thermal protector that automatically will turn off the pump if it becomes too hot. Overuse of this feature will damage the pump and void the warranty.
- Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow the pump to operate normally. If the pump is plugged in, it may restart unexpectedly.
ADDITIONAL SAFETY CAUTIONS
WORK AREA SAFETY
-
Know the pump applications, limitations, and potential hazards.
-
Make certain the electrical power source is adequate for the requirements of the pump.
-
ALWAYS disconnect the power to the pump and drain all water from the system before servicing.
-
Secure the pump on a solid base as close to the source of water as possible.
-
Secure the discharge hose before starting the pump. Pump torque may cause an unsecured discharge hose to “whip”, possibly causing personal injury and/or property damage.
-
Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly.
-
Check that all hose connections are tight to minimize leaks.
-
Connect the pump directly to a grounded GFCI outlet.
-
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a
life-threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. If using 50ft cord, use 16 (AWG) gauge wire. If using 100ft cord, use 14 (AWG) gauge wire. -
Make certain the electrical circuit to the pump is protected by a 10-amp or larger fuse or circuit breaker.
-
Periodically inspect pump and system components to ensure that the pump inlets are free of mud, sand and debris. DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.
-
Wear safety glasses at all times when working with pumps.
-
Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the workplace, the Occupational Safety and Health Act (OSHA).
-
This unit is designed only for use on 115 volts (single phase), 60Hz,and is equipped with an approved 3- conductor cord a 3-prong,grounding-type receptacle. Do not use the pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. AII wiring should be performed by a qualified electrician.
-
Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.
INSTALLATION INSTRUCTIONS
- Warning: Always use handle to lift pump. Never use a power cord to lift pump. To avoid skin burns unplug and allow time for the pump to cool after periods of extended use. Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list. If any part is missing or damaged do not attempt to assemble the product. Contact customer service for replacement parts.
- Estimated Assembly Time : 5 minutes
- Materials Required for Assembly (sold separately): thread tape, standard garden hose for discharge heavy duty garden hose.
- Note: If standard garden hose is used for suction line, the hose could collapse, allowing the pump to run dry. This could cause permanent damage and void warranty.
- This pump is designed to sprinkle lawns and small gardens from lakes, ponds, or rivers, empty or fill stock tanks, remove standing water from flooded areas or transfer water. Flammable liquids such as gasoline, chemicals, or corrosive liquids should never be used with this pump.
- Note: This pump is not intended for permanent installation or long, extended periods of continuous operation.
- Note: This pump is not to be used with pop-up sprinklers.
- WARNING: Place the pump on level support before operation.
- CAUTION: Never install a shutoff valve in the suction or discharge of this pump. This will cause excessive friction loss and will damage the pump and void the warranty.
- CAUTION: AII connections must be air tight. A single leak will prevent proper operation of the pump and may cause the pump to run dry.
If the pump runs dry, this will void the warranty.
- Positioning the Pump
- Place the pump as close as possible to the water source, keeping the vertical distance from the water to the pump as small as possible (max lift is 25 ft.).
- Place the pump (A) on level suppor1.
- Install a 3/4 in. foot valve, sold separately. when the suction lift is over 10ft. or when the suction line is more than 10ft. long. The foot valve will keep the pump primed when it is turned off.
- You can use a regular garden hose (sold separately) as the discharge line.
- Note: The inlet line may be PVC or reinforced hose. Small leaks in the suction line greatly reduce the efficiency of the pump and may prevent priming.
- Positioning the Hose Adapters
- Wrap threads of discharge tee (sold separately) with thread tape.
- Thread a 1in. discharge tee (2) into the outlet of the pump.
- Thread hose adapters (B) into pump outlet and into the discharge tee (2).
- Note: Discharge tee is optional.
- CAUTION: A|I connections must be air tight. A single leak will prevent proper operation of the pump and may cause the pump to dry. This will void the warranty.
- Installing the Pump :
- Connect a 3/4 in. heavy duty garden hose (sold separately) to the pump inlet (1). The inlet connection can also be used with 1 in. PVC pipe (Note: If you are using a PVC pipe, you will need a 1 in. male NPT X slip adapter.)
- Notice: The inlet hose must be a reinforced type when pumping from lakes, ponds, or small streams. A regular garden hose will collapse and lead to pump failure.
- Note: A foot valve MUST be used to maintain prime during operation. Foot valves are sold separately.
- Connect an outlet pipe or 3/4 in. standard garden hose (sold separately) to the discharge tee (2). The outlet connection is designed for a 1 in. NPT thread. Rigid pipes such as PVC or a garden hose may be used.
- Connect your discharge hose to a standard lawn sprinkler (Max. 2 sprinklers).
Note: This pump (A) is not designed to be used with underground, pop-up sprinklers (zoned systems). If you have this type of system, purchase a higher capacity law or irrigation pump.
OPERATION INSTRUCTIONS
WARNING: Do not run the pump with the outlet pipe or hose nozzle closed.
This will cause damage to the pump, or burst the hose from excessive pressure.
This could result in death or serious injury Use only reinforced high-pressure
hoses or pipes for the outlet connection or pipes for the inlet (suction)
connection.
WARNING: Never remove the ground prong on the power cord. Never hardwire
the power cord. Cutting the cord, hardwiring, or removing-the ground prong can
result in death or serious injury and will void the warranty.
- Priming the Pump:
- Note: The pump must be filled with water before operation. Running the pump dry will cause damage to the shaft seal and will void the warranty.
- Note: Add thread tape on the discharge tee cap a. Remove the prime plug (1) and the discharge tee cap (2). Fill water into top of discharge tee (3) until pump overflows with water Reinstall the prime plug (1) and the discharge tee cap (2) when finished priming.
- Usage: You can install a 100 pressure gauge (sold separately) on top of the discharge tee cap in order to monitor pressure.
- Note: This pump is not designed to be used with under-ground pop-up sprinklers (zoned systems) If you have this type of system purchase a higher capacity lawn or irrigation pump.
- Running the Pump:
- Plug the power cord into a GFCI protected electrical outlet and press the power switch to the On position. If the pump does not pump water with in 2 minutes, turn the pump (A) off. Refill with clean water and make sure all connections are air tight. To turn the pump off, press the power switch to the off position.
- DANGER: Risk of electric shock. Always disconnect the electrical supply before attempting to install, service, or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians should repair this unit. Improper repair could result in fatal electrical shock.
- WARNING: Let the pump cool for at least 20 minutes before attempting to service. The motor may be extremely hot. Personal injury may result.
- Storing the Pump:
- Protect against flooding and excessive moisture by storing in a dry place.
- Draining the Pump for winter:
- Disconnect the suction (1) and discharge (2) lines from the pump (A).
- Remove the water drain plug (3) from the pump (A).
- Drain all piping below the frost line or store the piping indoors.
- Store the pump indoors.
TROUBLESHOOTING
Problem | Possible Cause | Corrective Action |
---|---|---|
The pump will not start or run |
- There is a blown fuse or tripped circuit breaker in your home’s breaker/fuse box.
- The voltage is low.
- The impeller is blocked.
- The motor is defective.
|
- If blown, replace with a proper sized fuse or reset the breaker.
- If the voltage is less than 108 Volts, check the wiring size or use a shorter extension cord.
- Remove the blockage.
- Contact customer service at 833-290-1189.
The pump will not prime or retain prime after operating|
- There is an air leak in the suction line.
- The impeller is blocked.
- The seal is worn
- The suction lift is too high
- The hose is kinked or looped
- The fittings are not tight
- The suction hose is out of water
- The inlet is clogged.
|
- Repair or replace the suction line.
- Remove the blockage.
- Replace the seal.
- Lower the pump.
- Straighten the hose.
- Tighten the fittings.
- Submerge the suction hose end.
- Clean the inlet.
Flow rate too low|
- The piping or hose is fouled or damaged
- The voltage is low.
- The hose diameter is too small.
- The discharge hose is too small
|
- Clean or replace the piping or hose.
- If the voltage is less than 108 volts, check the wiring size or use a shorter extension cord.
- Use a minimum 3/4 in. heavy duty garden hose.
- Use as short a hose as possible (max 50 ft.).
The seal leaks|
- The seal is worn.
- The shaft is grooved.
- The pump head is loose on the motor.
|
- Replace the seal. Call for replacements.
- Replace the rotor. Call for replacements.
- Ensure the pump is assembled properly and that there is no obstruction.
PARTS DIAGRAM
Part No. | Description | Quantity |
---|---|---|
1 | Bolt M8*4 | 2 |
2 | Spring Washer 8 | 2 |
3 | washer 8 | 2 |
4 | Pump Support | 1 |
5 | Bracket For Pump Support | 2 |
6 | Column Tie Bolt M6*12 | 8 |
7 | Priming Plug | 2 |
8 | O-Ring 8.2*1.9 | 2 |
9 | Pump Casing | 1 |
10 | O-Ring 26.3*2.2 | 1 |
11 | Venturi Tube | 1 |
12 | Baffle | 1 |
13 | Diffuser | 1 |
14 | Hex Nut 10 | 1 |
15 | Spring Washer 10 | 1 |
16 | washer 10 | 1 |
17 | Impeller | 1 |
18 | O-Ring 163*3.55 | 1 |
19 | Mechanical Seal | 1 |
20 | Seal Holder | 1 |
21 | Seal | 1 |
22 | Pump Support | 1 |
23 | Cover | 2 |
24 | Bolt M4*8 | 2 |
Part No. | Description | Quantity |
--- | --- | --- |
25 | Cord Clip | 1 |
26 | Bolt M4*6 | 1 |
27 | Spring Washer 4 | 1 |
28 | Terminal | 1 |
29 | Fixing Water | 1 |
30 | Cable Holder | 1 |
31 | Ball Bearing 6202-Zz/Z2 | 2 |
32 | Shaft Key A4*10 | 1 |
33 | Rotor | 1 |
34 | Wave Spring | 1 |
35 | Motor Stator | 1 |
36 | End Plate | 1 |
37 | Washer 5 | 4 |
38 | Bolt M5*138 | 4 |
39 | Fan | 1 |
40 | Fan Cover | 1 |
41 | Power Cord | 1 |
42 | Sealing Ring For Terminal | 1 |
43 | Power Switch | 1 |
44 | Sealing Washer For Switch | 1 |
45 | Capacitor 40Mf/250V | 1 |
46 | Terminal Box | 1 |
47 | Screw | 2 |
Read User Manual Online (PDF format)