STELPRO INSAWFACF0522 WALL CEILING AERO CONVECTOR User Guide

June 5, 2024
StelPro

STELPRO AWF/ACF SERIES WALL/CEILING AERO CONVECTOR User Guide

STELPRO

SPECIFICATIONS

AWF SERIES - WITHOUT CONTROL

Add W for white, SW for soft white, S for silver or SS for stainless steel

ACF SERIES - WITHOUT CONTROL

Add W for white, SW for soft white, S for silver or SS for stainless steel

Several other models with control are available in higher voltages and wattages. For a complete model list, consult our online catalog at www.stelpro.com

For further information or to consult this guide online, please visit our website at www.stelpro.com

IMPORTANT INSTRUCTIONS

Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and keep them handy for future reference. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this product.

This product must be installed by a qualified person and connected by a certified electrician , according to the electrical and building codes effective in your region.

The following instructions must be adhered to in order to avoid personal injuries or property damages, serious injuries and potentially fatal electric shocks.

Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.

Make sure the line voltage (volt) is consistent with that indicated on the unit’s nameplate.

This unit must be grounded.

Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit.

Make sure the unit is appropriate for the intended use (if needed, refer to the product catalog or a representative). Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. Do not use outdoors.

RECOMMENDED HEATING CAPACITY: 1.25 W/cubic foot (0.03 m³)

It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling height of 8 feet (2.44 m). The recommended capacity is usually sufficient for normal heating needs. Please note that the insulation quality of walls and windows are some of the factors that influence heat losses, which modify the required capacity to heat a room. If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat losses and optimize the required capacity or consult the “Online heating calculation” section of the Stelpro Design Web site (residential buildings). To heat a large room and to increase your comfort, it is recommended to install several units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.

Do not install the unit where objects or pieces of furniture could be heat damaged.

If the unit capacity is insufficient for the size of the room, it will be in operation continuously, and may become defective earlier and turn yellow.

Respect distances and positions indicated in the installation section.

If the installer or the user modifies the unit, he will be held responsible for any damage resulting from this modification, and the CSA certification could be void.

This unit must not come into contact with a water source and must be protected from splashes. Do not use it if any part has been immersed.

When mounting the unit, make sure that the anchorage used can support the total weight of the unit with the mounting brackets.

When cutting or drilling into a wall or a ceiling, do not damage electrical wiring and other hidden utilities.

When starting up the unit for the first time or after a long period, it is normal that it produces some temporary odours and whitish smoke.

Because this unit is hot when in use, it may pose risks even in normal operation. Therefore, be careful and responsible when using it. To avoid burns, do not let bare skin touch hot surfaces. The unit must cool down for few minutes since it will stay warm for some time after shut-down. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.

This unit must be installed at least 6 inches (15.2 cm) from surrounding walls and 6 inches (15.2 cm) from the floor. The triple unit must be installed at least 12 inches (30.4 cm) from surrounding walls and 8 inches (20.32 cm) from the floor.

CAUTION – High Temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.

Do not install on a wall behind a door.

Never block air vents (with objects or other items). You risk damaging the heater and the obstruction could lead to electric shock or overheating, which could result in a fire.

Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, fires, or damages to the unit.

This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing flammable liquids, combustible materials or corrosive, abrasive, chemical, explosive and flammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning products.

Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on and inside air vents. Accumulated dirt can lead to a component malfunction or discoloration (yellow). It may cause a fire hazard if not installed and maintained in accordance with these instructions.

The thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or activates and deactivates repeatedly, it is recommended that a qualified electrician or a certified repair centre examine the unit in order to make sure it is not damaged. (Refer to the limited warranty)

Before unplugging the unit, all controls must be in the “OFF” position and the current from the main breaker panel should be cut. (The general switch may be used also, if included.) If the unit is damaged or defective, discontinue use, cut off power supply at circuit breaker and contact a certified electrician or certified repair centre. (Refer to the limited warranty)

Make sure that all the electrical connections have been secured and made properly. Pull each wire to ensure it is not loose in the connector or the terminal board as this may cause a fire.

If an option must be added, make sure it has been approved by Stelpro. This way, it will ensure that it has been tested in accordance with our safety rules and that an appropriate installation has been planned into the unit.

SAVE THESE INSTRUCTIONS

Note: When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual.

TECHNICAL DRAWINGS

SIMPLE UNIT

Simple Unit

DOUBLE UNIT

Double Unit

TRIPLE UNIT

Triple Unit

INSTALLATION

N.B. Cut off power supply at circuit breaker/fuse before proceeding to the installation and wiring connections. This product must be connected by a certified electrician, according to the electrical and building codes effective in your region. Consult the wiring plan found on the unit.
To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater. Do not mount in contact with combustible material. Do not mount in close proximity to another unit.

Keep the front and upper sides of the unit at least 3 feet (91 cm) from any adjacent surfaces. Moreover, make sure objects or pieces of furniture such as, but not limited to, blankets, towels, beds, laundry baskets, clothing, papers, electric wires and other flammable items, do not come into contact with the unit and keep them at least 3 feet (91 cm) from the unit. Failure to comply with this warning could lead to a fire. Some materials are more heat-sensitive than others, so make sure those near the unit can withstand heat.

When the unit is recessed, the flanged shoulders must rest on the finished surface of the wall or ceiling.

WARNINGS

  1. Recessed and surface installation of AWF units (wall mounting) must meet the minimum distances for single and double units (see figures 1 and 2). For ACF units (ceiling mounting), must be installed at no less than 12” (305 mm) from adjacent walls and between 8’ (244 cm) and 10’ (305 cm) from the floor (see figure 4).
  2. Triple units must meet a minimum distance of 12 inches (305 mm) from surrounding walls and 8 inches (203 mm) from the floor. For recessed installation opening for triple units, see figure 3.
  3. Recessed structure requirement on outside walls for AWF (wall mounting) and ACF (ceiling mounting) units is the same as for a window structure (refer to the applicable building codes effective in your area).
  4. For surface installation, put a wooden plate at the back of the gypsum in order to fix the unit to the wall securely. For the wooden plate dimensions, refer to the opening for the recessed application (see figures 2 and 3). Use the same dimensions for ceiling application (ACF).

Figure 1 and 2

Figure 4 and 5

Figure 8

SURFACE INSTALLATION

  1. Make sure you use the proper sleeve surface depending on the device you are installing: WFSA1 (single units), WFSA2 (double units), WFSA3 (triple units).
  2. Unscrewed the two (2) screws holding the grille (see figure 8) and remove.
  3. Remove the inlet of the frame (see figure 5) by unscrewing the four (4) screws.
  4. Open the KO to be used and insert the wire with connector.
  5. Place the frame against the wall, level and tighten with four (4) wood screws (not included) into the holes provided for this purpose (see figure 6).
  6. Replace the inlet, make the required electrical connections. Insert the sleeve surface into the grille and put back (see figures 5 and 8).

RECESSED INSTALLATION

  1. The opening in the wall must be made in accordance with acceptable standards (see figures 2 and 3, and Warning).
  2. Unscrew the two (2) screws holding the grille (see figure 8).
  3. Remove the inlet of the frame (see figure 5) by unscrewing the four (4) screws.
  4. Open the KO to be used and insert the wire with connector.
  5. Insert the frame into the opening, press the flap against the wall. Screw in wood screws (not included) in the left and the right studs, through holes provided for this purpose (see figure 7).
  6. Replace the inlet, make the required electrical connections and replace the grille.

SELECTING THE POWER

WARNING: risk of electric shock or fire hazard. Modification must be done by qualified electrician. Turn off power at the circuit breaker panel before switching the wattage.

To reduce the full factory wired wattage output by half, remove the jumper [A] to switch from 4000W to 2000W.

OPERATION, MAINTENANCE & TROUBLESHOOTING

OPERATION

WARNING : the unit must be properly installed before being used.

MAINTENANCE

All other repairs and maintenance other than those described in this guide should be performed by qualified service personnel. In order for the warranty to be valid, the unit must be cleaned regularly. Cut off power supply at circuit breaker/ fuse and wait for the unit to cool down before cleaning.

Use a soft rag for dusting. When cleaning, use only a damp rag and nonabrasive dish soap. If you use a cleaning product, always wipe the product off properly to avoid the discoloration of the unit. Do not use abrasive or chemical cleaners because they may damage the finishing. If the unit is used in a very dusty location, use a vacuum brush to remove dust and other foreign objects from the grilles. If needed, vacuum out the dust inside the unit. Note that cigarette smoke could yellow the discharge grille and that the best way to prevent it is to clean the unit on a regular basis.

Do not use cleaning products identified with these symbols:

N.B. There is electrical current linked to the unit even if the thermostat is set to “OFF”. This means that there is a risk of electric shock as long as the unit is energized.

TROUBLESHOOTING

Troubleshooting

N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the “Limited warranty” section to obtain the phone numbers).

REPLACEMENT COMPONENT LIST

Replacement Component List

Replacement Component List Continued

*Add W for white, SW for soft white, S for silver or SS for stainless steel

Parts Guide

STELPRO DESIGN INC. | Saint-Bruno-de-Montarville | Québec | J3V 6L7

Documents / Resources

| STELPRO INSAWFACF0522 WALL CEILING AERO CONVECTOR [pdf] User Guide
INSAWFACF0522 WALL CEILING AERO CONVECTOR, WALL CEILING AERO CONVECTOR, AERO CONVECTOR
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals