STELPRO FFI Series FFI1502W Floor Insert Fan Heater User Guide
- June 5, 2024
- StelPro
Table of Contents
STELPRO FFI Series FFI1502W Floor Insert Fan Heater
IMPORTANT INSTRUCTIONS
WARNING
- Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and keep them handy for future refer-ence. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this product.
- This product must be installed by a qualified person and connected by a certified electrician, according to the electrical and building codes effec-tive in your region.
- The following instructions must be adhered to in order to avoid personal injuries or property damages, serious injuries and potentially fatal electric shocks. Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.
- Make sure the line voltage (volt) is consistent with that indicated on the unit’s nameplate.
- This unit must be grounded.
- Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit.
- Make sure the unit is appropriate for the intended use (if needed, refer to the product catalog or a representative). Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. Do not use outdoors.
RECOMMENDED HEATING CAPACITY: 1,25 W/cubic foot (0.03 m³)
- It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling height of 8 feet (2.44 m). The recommended capacity is usually sufficient for nor-mal heating needs. Please note that the insulation quality of walls and windows are some of the factors that influence heat losses, which modify the required capacity to heat a room. If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat losses and optimize the required capacity or consult the “Online heating calculation” section of the Stelpro Design Web site (residential buildings). To heat a large room and to increase your comfort, it is recommended to install several units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.
- If the unit capacity is insufficient for the size of the room, it will be in operation continuously, and may become defective earlier and turn yellow.
- Do not install the unit where objects or pieces of furniture could be heat damaged.
- Respect distances and positions indicated in the installation section.
- If the installer or the user modifies the unit, he will be held responsible for any damage resulting from this modification, and the CSA certification could be void.
- This unit must not come into contact with a water source such as, but not limited to, showers, bathtubs, sinks, toilets, etc. and must be protected from splash-es. Do not use it if any part has been immersed. Moreover, do not turn it on or off when standing in water or if your hands are wet.
- When cutting or drilling into a floor, do not damage electrical wiring and other hidden utilities.
- Do not install this product on floors made of synthetic material such as, but not limited to, carpet.
- When starting up the unit for the first time or after a long period, it is normal that it produces some temporary odours and whitish smoke.
- Because this unit is hot when in use, it may pose risks even in normal operation. Therefore, be careful and responsible when using it. To avoid burns, do not let bare skin touch hot surfaces. The unit must cool down for few minutes since it will stay warm for some time after shut down. Extreme caution is neces-sary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
- DANGER – High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of this heater.
- Never block air vents (with objects or other items). You risk damaging the heater and the obstruction could lead to electric shock or overheating, which could result in a fire.
- Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, fires, or damages to the unit.
- This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing flammable liquids, combustible materials or corrosive, abrasive, chemical, explosive and flammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning products.
- Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on and inside air vents. Accumulated dirt can lead to a component malfunction or discoloration (yellow). It may cause a fire hazard if not installed and maintained in accordance with these instructions.
- The thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or activates and deactivates repeatedly, it is recommended that a qualified electrician or a certified repair centre examine the unit in order to make sure it is not damaged. (Refer to the limited warranty).
- Make sure that all the electrical connections are secure and have been made properly. Pull each wire to ensure it is not loose in the connector or the terminal board as this may cause a fire.
- If an option must be added, make sure it has been approved by Stelpro. This way, it will ensure that it has been tested in accordance with our safety rules and that an appropriate installation has been planned into the unit.
- Before unplugging the unit, all controls must be in the “OFF” position and the current from the main breaker panel should be cut. (The general switch may be used also, if included.)
- If the unit is damaged or defective, discontinue use, cut off power supply at circuit breaker and contact a certified electrician or certified repair centre. (Refer to the limited warranty)
SAVE THESE INSTRUCTIONS
Note: When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and illustration, may differ from the manual.
SPECIFICATIONS
FLOOR INSERT FAN HEATER
MODEL| FFI
VOLTS| 240/208 V
WATTS| 1000/750 AND 1500/1125 W
WEIGHT| 18 LB / 8.1 KG
HEIGHT| 6 3/8” / 163 MM
WIDTH| 14 1/4” / 362 MM
DEPTH| 7” / 178 MM
TECHNICAL DRAWINGS
INSTALLATION
N.B. Cut off power supply at circuit breaker/fuse before proceeding to
the installation and wiring connections. This product must be connected by a
certified electrician, according to the electrical and building codes
effective in your region. Consult the wiring plan found on the unit.
To reduce the risk of fire, do not store or use gasoline or other flammable
vapors and liquids in the vicinity of the heater.
Do not mount in contact with combustible material. Do not mount in close
proximity to another unit.
DANGER – High temperatures may be generated under certain abnormal
conditions. Do not partially or fully cover or obstruct the front of this
heater.
- Recessed installation between floor joists.
N.B. The shoulder must rest on the finished surface of the floor.
- This 16 gauge steel unit can be installed on concrete floors without having to add an additional cabinet or bracket.
- This unit must be installed at least 6” (152 mm) from adjacent walls.
- To ground the unit, connect the bare wire coming from the electrical panel to the green screw inside the connection box of the unit.
N.B. This heater must be controlled with a wall thermostat. (Thermostat not included)
OPERATION
Warning: the heater must be properly installed before it is used.
MAINTENANCE
All other repairs and maintenance other than those described in this guide
should be performed by qualified service personnel. In order for the warranty
to be valid, the unit must be cleaned regularly. Cut off power supply at
circuit breaker/fuse and wait for the unit to cool down before cleaning.
Use a soft rag for dusting. When cleaning, use only a damp rag and non-
abrasive dish soap. Do not use abrasive or chemical cleaners because they may
damage the finishing. If the unit is used in a very dusty location, use a
vacuum brush to remove dust and other foreign objects from the grilles. Note
that cigarette smoke could yellow the discharge grille and that the best way
to prevent it is to clean the unit on a regular basis.
Do not use cleaning products identified with these symbols:
N.B. Note that there is electrical current linked to the unit even if the thermostat is set off. This means that there is a risk of electric shock as long as the unit is energized.
REPLACEMENT COMPONENT LIST
REF. # | PART # | DESCRIPTION |
---|---|---|
1 | BLA-002 | 5’’ 27’ 4B BLADE |
2 | ECH133 | CLOSED ELEMENT 334 W/120 V |
2 | ECH150 | CLOSED ELEMENT 500 W/120 V |
2 | ECH050 | CLOSED ELEMENT 500 W/080 V |
3 | M-FFI00E1 | ALUMINUM GRILLE |
3 | M-FFI00D1 | STEEL GRILLE |
4 | MO-001 | 240 V MOTOR |
4 | MO-011 | 208 V MOTOR |
4 | MO-012 | 120 V MOTOR |
5 | PROT-003 | THERMAL PROTECTION (AUTO) |
6 | M-FFI09Z0 | GRILLAGE |
7 | PL-120 | 120 V PILOT LIGHT |
7 | PL-240 | 240 V PILOT LIGHT |
– | FLK-FFI | FUSE LINK KIT |
TROUBLESHOOTING
PROBLEM | DEFECTIVE PART OR PART TO CHECK |
---|
The unit does not work
| • Defective thermostat or wrong thermostat setting
• Open circuit breaker or fuse
• The thermal protection has been activated
• Faulty connections
The unit runs continuously| • Defective thermostat or wrong thermostat setting
• Heat losses higher than the unit capacity
The enclosure is extremely hot
| • Defective thermal protection
• Blocked air vents
• Defective motor
The unit cycles under control of the thermal protection (overheat indicator)| • Blocked air vents
• Defective motor
Overheating| • Defective thermostat or wrong thermostat setting
• Defective motor
The breaker trips when the heater is turned on| • Faulty connections
• Voltage higher than that written on the nameplate
Elements are on, but the motor does not work| • Defective motor
The desired room temperature cannot be reached
| • One or more elements are defective
• Defective thermostat or wrong thermostat setting
• Voltage lower than that written on the nameplate
• Heat losses higher than the unit capacity
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the “Limited warranty” section to obtain the phone numbers).
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and
applies to the following product made by Stelpro: model FFI. Please read this
limited warranty carefully. Subject to the terms of this warranty, Stelpro
warrants its products and their components against defects in workmanship
and/or materials for the following period from the date of purchase: 5 years.
This warranty applies only to the original purchaser; it is non-transferable
and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must
cut off the power supply at the main electrical panel and contact 1) your
installer or distributor, 2) your service center or 3) Stelpro’s customer
service department. In all cases, you must have a copy of the invoice and
provide the information written on the product nameplate. Stelpro reserves the
right to examine or to ask one of its representatives to examine the product
itself or any part of it before honoring the warranty. Stelpro reserves the
right to replace the entire unit, refund its purchase price or repair a
defective part. Please note that repairs made within the warranty period must
be authorized in advance in writing by Stelpro and carried out by persons
authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization
number (RMA). To obtain it, call the customer service department at:
1-800-363-3414 (electricians and
distributors – French), 1-800-343-1022
(electricians and distributors – English), or
1-866-766-6020 (consum-ers). The
authorization number must be clearly written on the parcel or it will be
refused.
CONDITIONS, EXCLUSIONS AND DISCLAIMER OF LIABILITY
This warranty is exclusive and in lieu of all other representations and
warranties (except of title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts or
omissions relat-ing thereto. Without limiting the generality of the foregoing,
Stelpro expressly disclaims any liability for property or personal injury
damages, penalties, special or punitive damages, damages for lost profits,
loss of use of equipment, cost of capital, cost of substitute products,
facilities or services, shut-downs, slowdowns, or for other types of economic
loss or for claims of a dealer’s customers or any third party for such
damages. Stelpro specifically disclaims all consequential, incidental and
contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from: 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro)
or a use other than that for which the unit was designed; 3) a natural disas-
ter or an event out of Stelpro’s control, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages nor does it cover damages caused by negligence
of the user or owner of the product. Moreover, it does not cover the cost of
disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the refund of its purchase price, at the discretion of Stelpro. Any parts re- placed or repaired within the warranty period with the written authorization of Stelpro will be warranted for the remainder of the original warranty period. This warranty will be considered null and void and Stelpro will have the right to refuse any claims if products have been altered without the written authorization of Stelpro and if the nameplate numbers have been removed or modified. This warranty does not cover scratches, dents, corrosion or dis-coloration caused by excessive heat, chemical cleaning products and abrasive agents. It does not cover any damage that occurred during the shipping.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some of them do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state or from province to province.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>