PRAGMA ARVIGOmoto3 R8 Q-SYS Motor-Faderpult Instruction Manual

June 5, 2024
PRAGMA

PRAGMA

PRAGMA ARVIGOmoto3 R8 Q-SYS Motor-Faderpult Instruction Manual

PRAGMA ARVIGOmoto3 R8 Q-SYS Motor-Faderpult

ARVIGOmoto3
ARVIGOmoto3 R8

Introduction

Thank you for purchasing a PRAGMA product.
Please read this instruction manual carefully before use to understand the correct handling method. We hope that you will continue to use it for many years to come.

After reading, please keep it in a place where you can refer to it at any time.
If you have any questions, please contact us using the contact information on the last page.

Safety notice

Please read this guide to the end.

  •  Do not install this device in an environment where it may be exposed to water.
  • Clean only with a dry cloth.
  • Keep away from fire.
  • Do not use if you notice any abnormalities (sound, smoke, odor, heat generation, etc.).
  • Install in a well-ventilated place.
  • Do not disassemble or modify the product.
  • There are no products that can be repaired by the user. In the unlikely event of a problem, please contact Audiob Co., Ltd.

Please contact Raines.

Product warranty

PRAGMA products are guaranteed for one year after purchase. If a problem occurs during normal operation will repair it free of charge for one year. However, the product may drop during transportation or movement, malfunction due to improper use, This warranty does not apply if the product has been modified, or if it breaks down while being used outside of Japan.

content

  • ARVIGOmoto3 body
  • Product warranty
  • Setting materials

Setting software

The ARVIGOmoto3 configuration software is Windows-based software.

PRAGMA Innovations Symetrix Tool for ARVIGOmoto3 software from the following website Please install the software.

Symetrix

Configuration

software ARVIGO moto3 is not compatible with previous software such as ARVIGOmoto2. Be sure to use Symetrix Tool for ARVIGOmoto3 to make settings.

FIG 1 Configuration

Find ARVIGOmoto in network

  • Click the Search button to search for the connected ARVIGOmoto3 and
  • Displays the IP address and MAC address of ARVIGOmoto3.
  • Click the Connect button to connect the selected ARVIGOmoto3 and display the setting information. can be viewed and changed. While connected, the Connect button toggles to a Disconnect button.
  • Click Disconnect to end communication with the connected ARVIGOmoto3.
  • Be sure to click Disconnect after completing the settings.

Network adapter

  • In this item, select the network adapter to which your ARVIGOmoto3 is connected. vinegar.
  • Refresh button if the device is not found or shows a different IP address
  • Please press the button to update.
  • If you cannot find the device, please check the network settings of your PC.

ARVIGO Configuration

In this item, you can configure each setting of ARVIGOmoto3.

Dual Fader Bank Mode

  • Check this item to switch to Dual Fader Bank Mode.
  • Single Fader Bank Mode (unchecked) Can be  used as 5 independent buttons, LEDs and 8 Faders.
  • Dual Fader  Bank Mode (checked)
  • You can use the 5th button/LED to toggle between 1-8 Faders and 9-16 Faders. increase.

Control ID

Sets and displays the Remote Control Number for each fader.

max. Level
You can specify the maximum value for each fader between 00000 and 65535.

Fader curve setting

Set the curve of each fader to Linear (linear taper) / Logarithmic (log taper). You can choose from
Press the All linear/All logarithmic button to change all faders at once. You can

Father fashion
If you check Disable, the fader will not be used. ÿ Button LED Color On / Button LED Color Off

You can select the color of the LED when the button is on or off. The  color of each button LED cannot be set individually, they are all the same color. The following colors can be selected.

  •  Off (LED off)
  • Red
  • Yellow
  • Green
  • Blue
  • Turquoise
  • Violet
  • White
  • PRAGMA (LED color used in the old ARVIGOmoto2)

Button IDÿLED ID
Sets and displays the Remote Control Number for each button and LED.

Heartbeat

Heartbeat function ON/OFF, Heartbeat output Remote Control Number set and display.
Heartbeat will periodically output a signal to the specified Remote Control Number,
This function is used to check the connection status between the DSP unit and ARVIGOmoto3.

Firmware version

Displays the firmware version of the connected ARVIGOmoto3.

IP Settings

In this item, you can set the IP address of ARVIGOmoto3.

ARVIGATION

You can set the IP address settings for the ARVIGOmoto3 main unit. IP address and press the Set button.
You can check the changed IP address with Find ARVIGOmoto in Network.
vinegar.

DSP

You can set the IP address of the Symetrix DSP that connects ARVIGOmoto3. vinegar. Enter the IP address and press the Set button.
You can check the current settings by pressing the Get button.

dB to Level calculator
Enter any number between -72dB and +12db and press the Convert button to convert from 00000 Convert to control value of 65535 and display.
This feature is useful when specifying max.Level.

Get Settings / Send Settings

Get Settings
Displays ARVIGOmoto3 settings.

Send Settings

Load the set information into ARVIGOmoto3. Be sure  to perform Get Settings after applying the settings, and check whether the settings are reflected. Please confirm.

Settings on the Symetrix

DSP side (1) Place the Gain module and set it on the Symetrix Tool for ARVIGOmoto3 software.

Assign the Control ID of any fader to the fader to be controlled.

(2) Place the x Button Momentary in the Control Module and use the Symetrix Tool for Any Button ID set on the ARVIGOmoto3 software is assigned to the Momentary Button.

Allocate to the ON part.
Also, when using the Heartbeat function, set it in the same way.

(3) Allocate an LED ID to light the LED of the switch.
Or assign an LED ID to the x Output Remote Control Number module, etc.

FIG 4 Settings on the Symetrix

Configuration example on the Symetrix DSP side

FIG 5 Configuration example on the Symetrix DSP side

FIG 6 Configuration example on the Symetrix DSP side

FIG 7 Configuration example on the Symetrix DSP side

How to change DSP presets using ARVIGOmoto3 switches

In this example, 4 presets are created and the logic to be called by each switch of ARVIGOmoto3. I will show you how to create a lock. At this time, the LEDs on the switch will indicate which preset is being recalled.

so that only the last-pressed switch lights up.

FIG 8

  1. Create any preset. This example Now use presets 1 to 4.

  2. Toolkit Control Modules > Control                                                                                  Place 4Button Latched in Inputs.
    place. Open the module and turn ON
    Right click for Remote Control
    Assign a Number. Remote Control Number is Symetrix Tool for
    Specify the same number as the Button ID set in the ARVIGOmoto3 software.

  3. Place Preset Trigger in Control Modules > Control Accessories and work as shown above. connect the ear. Open the Preset Trigger module and select the presets to recall one by one. Specify one.

  4. Now we have the logic to call any preset when the button is pressed. Next , create logic to light the switch’s LED depending on which preset is recalled. To do.

  5. Found in Control Modules > Control Inputs 4 Place a Button Radio. the module Assign an open preset. In this example 1 is selected at preset 1, and preset 2, and so on.  FIG 9

  6. Located in Control Module > Control Outputs 4 Place the Output Remote Control Number to set the Remote Control Number. vinegar. Remote Control Number is Symetrix Set with the Tool for ARVIGOmoto3 software. Specify the same number as the LED ID you specified.                       FIG 10

  7. Push the created file to DSP.
    *Please refer to the separate TechTip for how to set the presets and Remote Control Number on the Symetrix DSP side.

Specification

FIG 11 Specification

FIG 12 Specification

For inquiries regarding the handling of this product, please contact Audio Brains Co., Ltd.
Contact Please. Inquiries are accepted from 10:00 to 18:00, excluding Saturdays, Sundays, holidays, and company holidays.

Audio Brains Co., Ltd.

216-0034

3-1 Kajigaya, Miyamae Ward, Kawasaki City, Kanagawa Prefecture

Tel: 044-888-6761

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals