UNI-T UT343E Coating Thickness Gauge User Manual
- June 5, 2024
- UNI-T
Table of Contents
UT343E Coating Thickness Gauge
User Manual
P/N:110401110803X
PREFACE
Thank you for purchasing the new UT343E coating thickness gauge. In order to
use this product safely and correctly, please read this manual thoroughly,
especially the Safety Instructions part. After reading this manual, it is
recommended to keep the manual in an easily accessible place, preferably close
to the device, for future reference.
LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and
workmanship within one year from the purchase date. This warranty does not
apply to damages caused by accident, negligence, misuse, modification,
contamination, and improper handling. The dealer shall not be entitled to give
any other warranty on behalf of Uni-Trend. If you need warranty service within
the warranty period, please contact your seller directly. This warranty is the
only compensation you can obtain. Uni-Trend will not be responsible for any
special, indirect, incidental, or subsequent damage or loss caused by any
reason or speculation. As some areas or countries do not allow limitations on
implied warranties and incidental or subsequent damage, the above limitation
of liability and stipulation may not apply to you.
Overview
UT343E is an upgraded high-performance coating thickness gauge that can
measure coating thickness on both ferrous and non-ferrous matrixes. This
device has features of high precision, stable and reliable performance, and
non-destructive measurement. etc. It has functions such as automobile mode,
voice broadcast, and Bluetooth APP. LED flashlight. It is a necessary device
for automobile manufacturing, and sales. evaluation, metal processing,
painting, inspection, and other industries. It is widely used in
manufacturing. metal processing, aeronautics and space, shipping, bullet
trains, scientific research, quality supervision, and other fields.
The product is based on the principles of electromagnetic induction and eddy
current measurement. The principle of electromagnetic induction measurement is
to measure the coating thickness according to the size of the magnetic flux
flowing from the sensor through the non-ferrous magnetic coating into the
ferromagnetic matrix. The symbol is Fe. It can measure non-conductive or
conductive coatings on magnetically permeable metals such as iron and steel
(for example galvanized steel sheets). The principle of eddy current
measurement is to measure the coating thickness according to the difference in
the eddy current formed by an AC magnetic field on a non-magnetic metal matrix
(such as aluminum). The symbol is NFL. It can measure non-conductive coatings
on non-magnetic metal materials such as aluminum and copper. The matrix must
be metal, and the coating cannot conduct electricity.
Features:
- Does the measurement method conform to GB? 4956 non-magnetic coatings on magnetic matrices-measurement of coating thickness-magnetic method.
- The measurement method conforms to GB/T 4957 non-conductive coatings on a non-magnetic basis metals-measurement of coating thickness-eddy current.
- It has two thickness measurement methods: magnetic and eddy current.
- It can automatically or manually identify the ferrous or non-ferrous matrixes.
- Automatic voice broadcast of measured values
- Bluetooth APP communication and application
- It has a range of 2000pm.
- The sensor adopts diamond embedded technology, which has the characteristics of precision, wear resistance, and stability.
- Single and two-point calibration methods are adopted to correct the sensor systematic error and ensure measurement accuracy
- Single point/multi-point quick test mode (‘PASS” or “FAIL’)A
- 3-color warning light indicates the current value attribute (green: qualified; red: below the limit; yellow: above the limit).
- The screen can be automatically rotated or manually locked, which Is convenient for users to read the measured values from different angles.
- The high-capacity memory chip can store 3300 data.
- USB communication software: Communicate with the upper computer via USB to export stored data, draw trend graphs, take real-time measurements, and print.
- High-power LED flashlight
- 3.7V 4.81W11 rechargeable lithium battery
Accessories
Open the packing box and take out the gauge. Please double-check whether the
following accessories are missing or damaged.
1. Coating thickness gauge-…………….1 pc
2. User manual……………………….1 pc
3. Standard coating thickness sheets……………1 set (6 pcs)
4. Ferrous matrix………………………1 pc
5. Non-ferrous matrix……………………………1 pc
6. Sensor protective cover………………….1 pc
7. Hand strap……………………………1 pc
8. USB cable………………………………..1 pc
9. 3.7V 4.81Wh rechargeable lithium battery ……….1 pc
Safety Instructions
- An initialization self-test is needed for the gauge when it is powered on. When turning on the gauge, please do not put the sensor close to any metal objects, otherwise, the gauge will be unusable.
- Please keep the sensor clean and in good condition to avoid dust, oil, and other factors affecting the measurement accuracy.
- Do not use or store the gauge in high temperature, high humidity, flammable, explosive, and strong magnetic field environments
- Clean the gauge casing with a soft cloth and mild detergent. Do not use abrasives or solvents to avoid damage to the gauge.
- Do not disassemble or modify the gauge.
- When the LCD displays the low battery symbol “ “, charge the product in time.
- In order to prevent fire, when using the USB interface for charging or data communication, please use the original USB cable and disconnect it in time after use.
- Do not irradiate the flashlight in the eyes.
- When using the Bluetooth communication function, the distance between the host and the mobile terminal device should be less than 10 meters and there should be no obstacles or metal shielding objects in between.
- . The standard coating thickness sheets are high-precision accessories that are related to the accuracy of the gauge and need to be preserved properly to prevent scratches, corrosion, bending, and deformation of the surface.
- The metal matrixes also need to be preserved properly to prevent scratches, rust, oxidation, and deformation of the surface.
- If other failures occur, select “Restore factory settings” in the menu.
Function Description
4.1 Product Structure
1. LED alarming light
2. LCD
3. Power/flashlight
4. Confirm/menu
5. Cancel /delete
6. Subtract/automobile mode| 7. Add/histogram
8. Sensor module
9. Hand strap buckle
10. USB/charging interface
11. Flashlight
12. Loudspeaker
---|---
4.2 Display Interface
4.2.1 Menu Icons
| Auto-rotate screen| µm/mil| Units| Mode| Probe modes
---|---|---|---|---|---
Group| Storage location| | Measurement modes| | Upper limit
| Lower limit| | LED alarm| | Voice broadcast
| Calibration modes| | Languages| | Buzzer
| Backlight brightness| | Bluetooth communication| )| Restore factory
settings
Note: When the icon color becomes white, users can adjust the setting items.
When the icon is brown, users can only browse the setting items.
4.2.2 Main Interface
4.2.3 Single Point
4.2.4 Multi-Point
Operating Instructions
5.1 Power on/off
Long press to turn on/off the gauge.
5.2 Measurement
Note: Keep the probe away from metal objects before turning on the
product.
- Long press to power on. It will enter the main interface after initialization;
- If the product has not been used for a long time or the operating environment has changed, a two-point calibration is required before use;
- First, press the probe vertically on the object to be measured, and the value displayed on the LCD at this time is the estimated value of the coating thickness;
- Refer to this estimated value, and select a standard coating thickness sheet closest to this value from the accessories to prepare for two-point calibration;
- A matrix with the thickness of material close to the measured object and without coating should be selected as the calibration matrix as far as possible. When the above-mentioned matrix is not found, the standard matrix in the accessories can be selected as the calibration matrix (due to differences in material and thickness, the measurement results may be biased);
- Please refer to the calibration chapter for the two-point calibration method;
- After the two-point calibration is completed and verified repeatedly, the coating thickness of the object can be measured;
- When measuring, select 3 to 5 measuring points on the surface of the measured object evenly, measure 5 times for each point, and take the average value of the 5 times as the indicating value of the point.
- After the indicating values of the 3 to 5, measuring points are measured, the average of the values should be taken as the reference value of the object coating thickness.
Note
- Hold the gauge perpendicular to the object to be measured, and lightly press the gauge sensor against the object surface for measurement. It is necessary to keep the sensor in close contact with the object’s surface.
- When the measured indicating value is greater than 2000pm, the screen displays OL to indicate over range.
- When the measured indicating value is greater than 2200pm, the gauge will not respond.
5.3 Menu
In the main interface, short press to open the menu: 5.3.1 Auto Rotate Screen
In the menu, press or to select the auto-rotate screen icon , and then short
press to enter its setting interface. Press or to select to turn on/off the
auto-rotate function, and short press to confirm or to exit.
Note: The gauge has a built-in gravity sensor, which is convenient for
users to read the screen content from multiple angles (0°, 90°, 180°, and
270°). When the auto rotate function is turned off, the icon is displayed in
the upper right corner of the screen.
5.3.2 Length Unit
In the menu, press or select the length unit icon pm/mil, and then short press
to enter its setting interface.
Press or to select pm or mil, and short press to confirm or to exit.
5.3.3 Probe Mode
In the menu, press or select the probe mode icon Mode, and then short press to
enter its setting interface.
Press or to select automatic/ NFL/Fe mode, and short press to confirm or to
exit.
Automatic mode: In this mode, the matrix type of the measured object (Fe or
NFL) can be automatically identified. The sensor will enter a corresponding
operating mode according to the matrix type. Fe mode: The sensor will enter
the electromagnetic induction operating mode. NFL mode: The sensor will enter
the eddy current operating mode.
5.3.4 Data Storage Location
In the menu, press or select the data storage location icon Group, and then
short press to enter its setting interface.
Press or to select the group number, and short press to confirm ore to exit.
Note: There are 55 groups, and for each group, 60 data can be stored.
5.3.5 Continuous Measurement
In the menu, press or alto to select the continuous measurement icon, and then
short press ‘ ‘ to enter its setting interface.
Press or to select to turn on/off the continuous measurement mode, and short
press to confirm or to exit.
Note: When this mode is turned on, the product will continue to measure
until it is turned off.
5.3.6 Upper Limit
In the menu, press or select the upper limit icon T, and then short press to
enter its setting interface. Short press Ca org to add/subtract 1 to the
single digit of the upper limit, and long press to add/subtract 1 to the tens
digit. Short press M to confirm org to exit.
Note: When the measured value is higher than the upper limit and the LED alarm
is turned on, the LED light flashes yellow.
5.3.7 Lower Limit
In the menu, press c&orS to select the lower limit icon a, and then short
press 4 to enter its setting interface. Short press st or 1 to add/subtract 1
to the single digit of the lower limit, and long press to add/subtract 1 to
the tens digit. Short press g to confirm org to exit. Note: When the measured
value is lower than the lower limit and the LED alarm is turned on, the LED
light flashes red. When the measured value is between the upper limit and the
lower limit and the LED alarm is turned on, the LED light flashes green.
5.3.8 LED Alarm
In the menu, press or Sto select the LED alarm icon It, and then short press
E! to enter its setting interface. Press org to select to turn on/off the LED
alarm, and short press a to confirm org to exit.
5.3.9 Voice Broadcast
In the menu, press or to select the voice broadcast icon , and then short
press to enter its setting interface. Press or select to turn on/off the voice
broadcast function, and short press . to confirm or to exit.
5.3.10 Calibration Mode
In the menu, press or to select the calibration mode icon , and then short
press interface. Press or to select a calibration mode (single or two-point),
and short press g to confirm or to exit.
Note: The two-point calibration mode is more commonly used than the
single-point mode. to enter its setting
5.3.11 Language
In the menu, press or to select the language selection icon and then short
press to enter its setting interface. Press or to select English or Chinese,
and short press to confirm or to exit.
5.3.12 Buzzer
In the menu, press or to select the buzzer icon , and then short press to
enter its setting interface. Press or to select to turn on/off the buzzer, and
short press to confirm or to exit. When this function is turned on and the
gauge gets the measured value in the normal measurement mode, the buzzer will
beep.
5.3.13 Backlight Brightness
In the menu, press or to select the backlight brightness icon; , and then
short press to enter its setting interface. Press V3, or to adjust the
brightness, and short press to confirm or to exit.
5.3.14 Bluetooth
In the menu, press or to select the Bluetooth icon , and then short press to
enter its setting interface. Press or to select to turn on/off the Bluetooth,
and short press to confirm or to exit.
Note: If there is no connection for 5 minutes, the Bluetooth function
will be automatically turned off.
5.6.1 Zero-Point Calibration
a. Place the gauge vertically on the uncoated matrix, as shown in Figure 1;
b. Pick up the gauge after 2 seconds, the screen displays the value 0.0, as
shown in Figure 2, and the gauge automatically returns to the main interface;
c. The zero-point calibration is completed.
5.6.2 Two-Point Calibration
a. Stack the standard coating thickness sheet (take 500pm as an example) and
uncoated matrix together for calibration, as shown in Figure 3;
b. Pick up the large after 2 seconds, and the measured value shows on the
screen, as shown in Figure 4;
c. Press or to adjust the measured value to make it the same as the thickness
value of the standard coating—thickness sheet, as shown in Figure 5;
d. Press to confirm or press to cancel the calibration;
e. Place the gauge vertically on the uncoated matrix, as shown in Figure 6;
f. Pick up the gauge after 2 seconds, the screen displays the value 0.0, as
shown in Figure 7, and the gauge automatically returns to the main interface;
g. The two-point calibration completed.
5.6.3 Calibration Verification
In the main interface, measure the thickness of the standard coating thickness
sheet. The measured value should be within the error range of the nominal
value of the standard coating thickness sheet. For example, if the nominal
value is 100pm, the measured value should be within the specified range of the
technical index, otherwise, it needs to be recalibrated.
Note: If the gauge is inaccurate due to multiple incorrect calibration
operations, select “Restore factory settings” in the menu.
5.7 Flashlight
In the main interface, short press once to turn on/off the flashlight in the
rear of the gauge.
5.8 Bluetooth APP
Users can download the APP on Uni-Trend’s official website or APP Store. Note:
Please refer to the application instruction to know how to use the APP.
5.9 Upper Computer Software
- Refer to the installation instruction to download and install the upper computer software;
- Connect the USB cable to the computer;
- Via the USB interface, users can send real-time data or save the stored data to the computer and generate reports.
Note: Regarding the operation method of the upper computer software, users can open the user manual in the help option of the software interface for reference.
Performance Indexes
6.1 Technical Indexes
Function | Range | Thickness | Resolution | Accuracy | Description |
---|---|---|---|---|---|
Ferrous and non-ferrous matrixes measurement (Fe and NFe) | 0∼ 2000pm | ||||
0∼99.9pm | 0.1pm | ±(2%H+2)pm | 1 mil=25.4pm | ||
100∼2000pm | 1pm | ||||
0∼78.7mil | 0∼4.99mi1 | 0.01mil | ±(2%H+0.08) mil | ||
5.0∼78.7mil | 0.1mil | ||||
Bluetooth APP | System requirements | ||||
Searching time | 5min | If there is no connection for 5 |
minutes, the Bluetooth function
will be automatically turned off.
Transmission distance| ≥10m|
Probe measuring force| 0.3∼1.5N| Probe measuring force range
Display| Color display| 2″ color TFT screen
Auto rotatable screen| According to the built-in gravity sensor| 4 directions:
0°, 90°, 180°, and 270°
Unit conversion| pm/mil| Metric/imperial unit conversion
LED alarm| The LED lights up in the corresponding color when the value exceeds
the set range for alarm.|
Audio alarm| When measuring, alarming, and pressing buttons,
there will be corresponding prompt sounds.| The buzzer must be turned on.
---|---|---
Limit setting| 0∼2000pm|
Measurement modes| Single/continuous|
Statistical measurement| MAX/MIN/AVG|
Matrix identification modes| Auto/manual|
Voice broadcast| Voice broadcast for measured values| The voice broadcast
function must be turned on.
Flashlight| Easy to use in dark environments|
USB communication| Upper computer communication| Export stored data via the
upper computer
Data storage| 3300 data (55 groups * 60)|
Backlight brightness| 5 levels|
Auto power off| 5 minutes|
Low battery indication| Low battery indication at 3.4Vt0.2V|
Power| 3.7V 1300mAh lithium battery|
Operating environment| 0∼40°C ≤80%RH|
Storage environment| -20∼60°C ≤ 75%RH|
6.2 General Specifications
- Display: 2″ color TFT screen
- Refresh rate: 0.5s
- Sensor type: Large range composite sensor
- Impact resistance: can withstand 1 meter drop
- Power: 5VDC 1A power adapter (USB interface)
- Product size: 152x65x35mm
- Weight: about 180g (including battery)
UNI-TREND TECHNOLOGY (CHINA) CO., LTD.
No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City,
Guangdong Province, China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>