STELPRO SKS Series SKS1002W Kick Space Heater Installation Guide
- June 5, 2024
- StelPro
Table of Contents
SKS Series SKS1002W Kick Space Heater
Installation Guide
This unit complies with CSA standards
WARNING
Before installing and operating this product, the user and/or installer must
read, understand and follow these instructions and keep them handy for future
reference.
If these instructions are not followed, the warranty will be considered null
and void and the manufacturer deems no further responsibility for this
product.
This product must be installed by a qualified person and connected by a
certified electrician , according to the electrical and building codes
effective in your region.
The following instructions must be adhered to in order to avoid personal and
serious injuries, property damages, and potentially fatal electric shocks.
Protect the heating unit with the appropriate circuit breaker or fuse, in
accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the
unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing,
and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to
the product catalog or a representative).
RECOMMENDED HEATING CAPACITY:
1.25 W/cubic foot (0.03 m³)
WARNING
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling
height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and
windows are some of the factors that influence heat loss, which modify the
required capacity to heat a room. If needed, refer to a specialist (industrial
and commercial buildings) who will be able to calculate these heat losses and
optimize the required capacity or consult the “Tools/Heating Calculator”
section of the Stelpro Design website (residential buildings).
Do not install the unit where objects or pieces of furniture could be damaged
by heat.
If the unit capacity is insufficient for the size of the room, it will be in
operation continuously and may become defective earlier and turn yellow.
Respect distances and positions indicated in the installation section.
If the installer or the user modifies the unit, he will be held responsible
for any damage resulting from this modification, and the CSA certification
could be void.
This unit must not come into contact with a water source and must be protected
from splashes (e.g. a wet mop). Do not use it if any part has been immersed.
Moreover, do not turn it on or off when standing in water or if your hands are
wet.
When starting up the unit for the first time or after a long period, it is
normal that it produces some temporary odors and a whitish smoke.
Because this unit is hot when in use, it may pose risks even in normal
operation. Therefore, be careful and responsible when using it. To avoid
burns, do not touch hot surfaces with bare skin. Allow the unit to cool down
for a few minutes since it stays warm for some time after shut-down.
The maximum overhang distance from the front of the unit is 2 to 4 inches (5
to 10 cm) (according to the model) when installed as a kick space heater.
However, make sure objects or pieces of furniture do not come into contact
with the unit and keep them at least 6 inches (15.2 cm) from the unit.
Failure to comply with this warning could lead to a fire. Some materials are
more heat-sensitive than others, so make sure those near the unit can
withstand heat.
Never block unit air vents. This obstruction could lead to overheating, which
could result in a fire.
Do not insert or allow foreign objects to enter the air vent as this may cause
electric shocks, fires, or damage to the unit.
This unit becomes very hot and may generate arcing and sparking. It is not
designed to be used or stored in wet areas or areas containing flammable
liquids, combustible materials, or corrosive, abrasive, chemical, explosive
and flammable substances such as, but not limited to, gasoline, paint,
chlorine, sawdust, and cleaning products.
Some areas are dustier than others. Thus, it is the user’s responsibility to
evaluate if the unit must be cleaned based on the amount of dirt accumulated
on and inside air vents. Accumulated dirt can lead to a component malfunction
or discoloration (yellow). It may cause a fire hazard if not installed and
maintained in accordance with these instructions.
The thermal protection activation indicates that the unit has been subjected
to abnormal operating conditions. If the thermal protection remains activated
or activates and deactivates repeatedly, it is recommended that a qualified
electrician or a certified repair center examine the unit in order to make
sure it is not damaged. (Refer to the limited warranty)
If the unit is damaged or defective, cut off the power supply at the circuit
breaker and call a certified repair center. (Refer to the limited warranty)
TECHNICAL DRAWINGS
SPECIFICATIONS
KICK SPACE HEATER / SKS SERIES
VOLTS| 120, 240/208
WATTS (2 CHOICES)| 500 OR 1000, 500/375 OR 1000/750
WEIGHT| 10 LB / 4.5 KG
WIDTH| 21 3/4″ / 552 mm
HEIGHT| 3 3/4″ / 95.3 mm
DEPTH| 9 15/16″ / 253 mm
INSTALLATION
Cut off power supply at circuit breaker/fuse before proceeding with the
installation.
N.B. This product must be connected by a certified electrician, according
to the electrical and building codes effective in your region.
- Cut the required opening according to the dimensions shown below. (FIGURE 1)
- Unscrew the lid and open it. (FIGURE 2)
- Make the required electrical connections. Make sure to properly ground the unit and to choose the desired power, according to the image below. (FIGURE 3)
- Screw the lid in place. (FIGURE 2)
- Recess the unit into the cut opening and level it with a spacer.
- Secure the unit to the wall with wood screws (not supplied).
- Align the drill holes and secure them with the supplied screws.
N.B. This unit may be controlled by using either a wall thermostat or a
built-in mechanical thermostat (thermostat not included).
N.B. This unit is not meant to be installed into a floor recess.
MAINTENANCE
N.B. In order for the warranty to be valid, the unit must be cleaned
regularly.
Cut off power supply at circuit breaker/fuse before cleaning this heater. Use
a soft rag for dusting. When cleaning, use only a damp rag and non-abrasive
dish soap. Do not use abrasive or chemical cleaners because they may damage
the finish. If the unit is used in a very dusty location, use a vacuum brush
to remove dust and other foreign objects from the grilles. Note that cigarette
smoke could yellow the discharge grille and that the best way to prevent it is
to clean the unit on a regular basis.
Do not use cleaning products identified with these symbols:
N.B. There is an electrical current linked to the unit even if the
thermostat is set to off. This means that there is a risk of electric shock as
long as the unit is energized.
TROUBLESHOOTING
PROBLEM | DEFECTIVE PART OR PART TO CHECK |
---|---|
The unit does not work | • Defective thermostat or wrong thermostat setting |
• Open circuit breaker or fuse
• The thermal protection has been activated
• Faulty connections
The unit runs continuously| • Defective thermostat or wrong thermostat
setting
• Heat losses higher than the unit capacity
The enclosure is extremely hot| • Defective thermal protection
• Defective motor
• Blocked air vents
The desired room temperature cannot be reached| • One or more elements are
defective
• Defective thermostat or wrong thermostat setting
• Voltage lower than that written on the nameplate
• Heat losses higher than the unit capacity
Room overheating| • Defective thermostat or wrong thermostat setting
The unit cycles under the control of the thermal protection| • Blocked air
vents
The breaker trips when the heater is turned on| • Faulty connections
• Voltage higher than that written on the nameplate
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the “Limited Warranty” section to obtain the phone numbers).
REPLACEMENT COMPONENT LIST
REF. # | PART # | DESCRIPTION |
---|---|---|
1 | BLA-002 | BLADE 5″ 27′ 4B |
2 | ECH150 | CLOSED ELEMENT 500 W/120 V |
2 | ECH250 | CLOSED ELEMENT 500 W/240 V |
3 | M-SKS12Z* | STANDARD SKS GRILL |
3 | M-SKS14ZSS | STAINLESS STEEL SKS GRILL |
4 | MO-001 | MOTOR 240 V |
4 | MO-012 | MOTOR 120 V |
5 | PROT-005 | THERMAL PROTECTION L-175 |
6 | SWI-006 | SWITCH |
– | FLK-SKS | FUSE LINK KIT |
OPTIONAL
REF. # | PART # | DESCRIPTION |
---|---|---|
A | SKSR* | RETROFIT SKS GRILL |
B | SKST1 | BUILT-IN SINGLE POLE THERMOSTAT |
C | SKST2 | BUILT-IN TAMPER-PROOF DOUBLE POLE THERMOSTAT |
D | BOUT-015 | ALMOND THERMOSTAT KNOB |
D | BOUT-016 | WHITE THERMOSTAT KNOB |
D | BOUT-017 | BLACK THERMOSTAT KNOB |
- Add W for white, SW for soft white, SS for stainless steel
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design Inc. (“Stelpro”) and
applies to the following product made by Stelpro: model SKS. Please read
this limited warranty carefully. Subject to the terms of this warranty,
Stelpro warrants its products and their components against defects in
workmanship and/or materials for the following periods from the date of
purchase: 5 years. This warranty applies only to the original purchaser;
it is non-transferable and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must
cut off the power supply at the main electrical panel and contact 1) your
installer or distributor, 2) your service center or 3) the Stelpro customer
service department. In all cases, you must have a copy of the invoice and
provide the information written on the product nameplate. Stelpro reserves
the right to examine or to ask one of its representatives to examine the
product itself or any part of it before honoring the warranty. Stelpro
reserves the right to replace the entire unit, refund its purchase price, or
repair a defective part. Please note that repairs made within the warranty
period must be authorized in advance in writing by Stelpro and carried out by
persons authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization
number (RMA). To obtain it, call the customer service department at 1 800
363-3414 (electricians and distributors – French), 1 800 343-1022
(electricians and distributors – English), or 1 866 766-6020 (consumers).
The authorization number must be clearly written on the parcel or it will be
refused.
CONDITIONS, EXCLUSIONS, AND DISCLAIMER OF LIABILITY
This warranty is exclusive and in lieu of all other representations and
warranties (except title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort, or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts, or
omissions relating thereto.
Without limiting the generality of the foregoing, Stelpro expressly disclaims
any liability for property or personal injury damages, penalties, special or
punitive damages, damages for lost profits, loss of use of equipment, cost of
capital, cost of substitute products, facilities, or services, shutdowns,
slowdowns, or for other types of economic loss or for claims of a dealer
customer or any third party for such damages. Stelpro specifically disclaims
all consequential, incidental, and contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro),
or use other than that for which the unit was designed; 3) a natural disaster
or an event out of the control of Stelpro, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages nor does it cover damages caused by the
negligence of the user or owner of the product. Moreover, it does not cover
the cost of disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the
refund of its purchase price, at the discretion of Stelpro. Any parts
replaced or repaired within the warranty period with the written authorization
of Stelpro will be warranted for the remainder of the original warranty
period. This warranty will be considered null and void and Stelpro will have
the right to refuse any claims if products have been altered without the
written authorization of Stelpro and if the nameplate numbers have been
removed or modified. This warranty does not cover scratches, dents, corrosion,
or discoloration caused by excessive heat, chemical cleaning products, and
abrasive agents. It does not cover any damage that occurred during the
shipping.
Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages and some of them do not allow limitations
on how long an implied warranty lasts, so these exclusions or limitations may
not apply to you. This warranty gives you specific legal rights and you may
have other rights which vary from state to state or from province to province.
STELPRO DESIGN INC.
Saint-Bruno-de-Montarville
Québec
J3V 6L7
For further information or to consult this guide online,
please visit our website at www.stelpro.com
INSSKS0622
Documents / Resources
|
STELPRO SKS Series SKS1002W Kick Space
Heater
[pdf] Installation Guide
SKS Series, SKS1002W, Kick Space Heater, SKS Series SKS1002W Kick Space Heater
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>