- DeLaval IPR HDX/FDX 12-24VDC Max 6W KF-00020-TJ In Place Reader
- Safety precautions
- Disclaimer
- Definitions of admonishments
- Safety regulations
- Compliance with national regulations
- Type plate
- Warranty
- Regulatory compliance
- General description
- Technical data
- Planning
- Reading volume
- Troubleshooting
- Disposal
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DeLaval IPR HDX/FDX 12-24VDC Max 6W KF-00020-TJ In Place Reader
Safety precautions
Foreword
The safety and operational instructions must be observed by any person involved with the use or operation of this equipment. Under no circumstances must the equipment be used if it is damaged or if the operation of the equipment is not completely understood.
Disclaimer
The information, instructions, and parts listed are applicable and current on the date when issued. DeLaval reserves the right to make changes without notice.
Definitions of admonishments
Admonishments are safety-related warning messages. Admonishments provide important information intended to prevent incorrect or hazardous use of equipment, machinery or software, and support risk assessment. The following list defines the different types of admonishments used in DeLaval documentation:
Danger: Refers to imminent and severe risk. Failure to comply with instructions will result in serious injury or death.
Warning: Refers to potential but severe risk. Failure to comply with instructions could result in injury or death.
Caution: Refers to limited risk. Failure to comply with instructions could result in minor injury. Mandatory: Refers to an action or behavior which is essential to the safe and successful use of the equipment.
Prohibited: Refers to an action or behavior which is incompatible to the safe and successful use of the equipment.
Note: Is intended to draw attention to specific points of importance in the text and advice to prevent equipment damage.
- This symbol signals the risk of injury.
- This symbol signals the risk of electric shock.
- For other symbol definitions see ISO 7010.
Safety regulations
Safety regulations – General
Warning: Intended use
- Do not use the equipment for any other purposes than the intended use.
Warning: Keep safety signs legible!
- Read all the safety signs on the machine and in this manual.
- Replace any lost or damaged signs.
- Keep safety signs clean and legible at all times.
Mandatory
Read the instructions carefully before using the equipment. Contact the local DeLaval dealer if there are parts of these instructions that are not understood. Compliance with the instructions ensures correct and safe use of the equipment. Save the instructions for future reference. DeLaval in place ID reader IPR Safety precautions ©
Prohibited
Do not use inadequate parts or consumables. Using products that do not meet specified requirements, for example, spare parts or consumables, or not appropriately trained personnel for the DeLaval product may lead to risks or damage. Consequently, it may also void or limit the warranty.
Compliance with national regulations
FCC Compliance Statement
This equipment was tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection] against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and] used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference.
- this device must accept any interference received, including interference that may cause undesired operation.
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Note! Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. DeLaval in place ID reader IPR Safety precautions ©
ISED Compliance Statement
This device contains license-exempt transmitter( s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Note! Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Type plate
- A: Product name
- B: Model
- C: Article number
- D: Power
- E: FCC ID
- F: IC
- G: European Conformity mark
- H: China RoHS symbol
- J: The symbol of the crossed-out wheelie bin with the horizontal bar beneath, see Ä Chapter 1 ” Disposal and recycling information ” on page 19.
Warranty
Note
- DeLaval will not take any responsibility for damage resulting from faulty installation, or operation, or for improper or inadequate care and maintenance.
- Modification may create risks not covered by the original construction. Do not make any modifications that have not been approved by DeLaval.
Regulatory compliance
- For more information on regulatory compliance, see: http://www.delavalcorporate.com/sustainability/our-operations/regulatory-Compliance/.
General description
Introduction
- DeLaval in place ID reader IPR identifies animals with B-transponders (for the neck), or with ISO transponders (HDX and FDX transponders for the ear).
- The IPR is designed for various applications, including milking systems and feeding systems. The reader sends the scanned data to a receiving unit, for example, a milking station controller, when a transponder is within the range of the reader. The data is later processed by the receiving unit. After the receiving unit processed the data, the programmed action follows.
Technical data
- DeLaval in place ID reader IPR dimensions.
Technical data
Power supply| 12 or 24 VDC
TX Frequency| 134 200Hz
RX Frequency| 95000
-138000 Hz
Supply current (transmitting)| 6 W, 0.5 A (12 VDC) / 0.25 A
(24 VDC)
Supply current (standby)| 2 W, 0.2 A (12 VDC) / 0.1 A (24 VDC)
Weight| 2.8 kg (including the cable)
Minimum ambient temperature| -25°C (during operation)
Maximum ambient temperature| 55°C (during operation, 70°C during
storage)
Minimum ambient humidity| 20%
Maximum ambient humidity| 70%
Article number | Description | Type of animal transponder |
---|---|---|
2150015681 | DeLaval in place ID reader IPR H/F | ISO (HDX+FDX) |
2150015688 | DeLaval in place ID reader IPR B | B-Transponder |
Wire description for 2150015681/2150015688 and 2150009406/2150009407
IPR wire number| MPC connection terminal for rod reader|
Function
---|---|---
1| Red| 12-24V DC
2| Black| Ground
3| Green| Data
4| White| Synchronization
Wire description for 87486380 and 87486381
IPR wire color| MPC connection terminal for rod reader|
Function
---|---|---
Red| Red| 12-24V DC
Black| Black| Ground
Green| Green| Data
White| White| Synchronization
Planning
Suggested configuration layout
DeLaval in place ID reader IPR is fastened directly with four bolts on the metal surface without the need for additional protection. However, the associated cable must be well protected. The reader should not be located close to any metal objects, as they can cause disruptions in ID readings and reduce the reading distance. The minimum required distance is 100 mm at the sides and 500 mm at the front. Metal objects (including the IPR bracket) placed directly behind the reader do not affect system operation.
Note: Be aware that surrounding metal objects may cause a disturbance.
- A: More than 100 mm
Reading volume
The DeLaval in place ID reader IPR generates a magnetic field around the reader which activates the transponder. The magnetic field is automatically tuned to give optimum performance within certain limits in various applications.
The activation volume (reading volume) differs depending on the transponder type (HDX, B, or FDX), see Fig. 6 and Fig. 7.
Note: Metal objects close to the reader may impact the reading volume (reading performance).
- The DeLaval in-place ID reader IPR is capable of handling different positions (angles) of the transponder, which guarantees a highly accurate reading.
Troubleshooting
Problems with the in-place reader (IPR)
No. | Symptom | Cause | Action |
---|
- | Decreased reading distance.| Disturbances are caused by metal objects placed near the reader.|
- Remove all metal objects located within a distance of less than 100 mm from the sides or 500 mm at the front of DeLaval in place of ID reader IPR.
- Restart the reader.
-
| The IPR reports unexpected ID numbers.| More than one transponder in the reading area.| Ensure a single transponder reading and eliminate cross- reading.
-
| The IPR does not read any transponders.| No power supply connected to the DeLaval in place ID reader IPR or wire issues.|
- Check the power supply.
- Check the supply voltage (12 or 24 V DC).
- Contact an authorized service technician.
Disposal
Disposal and recycling information
- When the product reaches the end of life, dispose of it properly in accordance with local laws and regulations.
Disposal of packaging material
- (Packaging EU Directive 94/62/EC)
- This symbol indicates that the product’s packaging material can be recycled.
Disposal of electrical and electronic equipment with or without battery
- (WEEE European Directive 2012/19/EU)
- (European Battery Directive 2006/66/EC)
These symbols with a crossed-out wheelie bin on the product or its packaging indicate that the equipment is electrical waste, with or without battery,and shall not be disposed of with household waste. A horizontal bar beneath the bin means that the product is manufactured after August 13, 2005. To prevent inappropriate waste handling of this product, and its negative consequences on the environment and human health, all products shall be disposed of in accordance with local laws and regulations. Hand it over to an official recycling facility, or use a battery disposal facility when available. Please contact the local municipal office for information on the nearest recycling station.
EU Declaration of Conformity
- Name of product: DeLaval in place ID reader IPR
- Type/model: IPR
- Report No: D0000106871
- The product complies with the requirements of the following directives
- Restriction of the use of certain hazardous substances (RoHS) – 2011/65/EU
- Radio equipment directive RED 2014/53/EU
- Harmonized standards that have been used or parts thereof
- EN 300 220-2 V2.4.1: 2012
- EN 301 489-1 V2.2.0
- EN 301 489-3 V2.1.1
- Other technical standards and specifications used
- EN 55032:2012 + AC:2013
- EN 62368-1:2014
- Fulfills RoHS by design and purchase control
This declaration of conformity is issued under the sole responsibility of the manufacturer.
- Tumba 2020-06-19
- Signed:
- Name: Magnus Berg
- Position: Executive Vice President
- Department: Product Management & Development
A person authorized to compile the technical file
- Product Manager
- P.O. Box 39
- SE 147 21 TUMBA
- Sweden
Name and address of the manufacturer
- DeLaval International AB
- P.O. Box 39
- SE 147 21 TUMBA
- Sweden©
is a registered trademark of Tetra Laval Holdings & Finance S. A. and DeLaval is a registered trade/service mark of DeLaval Holding AB?
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>