UNPACKING
Carefully remove the DD400P dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing, it will be useful when transporting the dehumidifier unit in the future.

INTRODUCTION
Dehumidifiers remove moisture from the air that is circulating through the unit. The resulting reduction of relative humidity helps prevent rust, rot, mold, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used. The DD400P is of the desiccant wheel type designed to dry air by passing a large volume of air, the “process” air through a slowly rotating Silica gel rotor. Silica gel is a hygroscopic material that absorbs moisture direct from the air. As the air passes through the rotor the humidity of the air is reduced, whilst the moisture content of the rotor is increased. A smaller volume of air, the reactivation air, is heated by an internal heater and passes through a portion of the rotor in the opposite direction. As this heated air passes through the rotor it will “reactivate” it by removing the moisture content from the silica gel material. The reactivation air will leave the humidifier as warm, moist air and must be vented to outside of the building.
Continuous circulation of the room air through the dehumidifier unit gradually reduces the relative humidity in the room.
The DD400P dehumidifier is a robust, compact unit designed to control the humidity in the enclosed space in which it is placed. The casing is a welded steel construction which is epoxy coated for resilience to damage caused by rough handling. The unit has been designed for the exacting conditions which can prevail in offices, shops, houses, restaurants, public houses etc. It combines lightness and compactness with high reliability and strength.
The unit is thermally protected and will switch off if the maximum operating temperature of 40ºC is exceeded.
The dehumidifier has two separate filters. One in the “process” air inlet and one in the “reactivation” air inlet, used to clean the air entering the dehumidifier.

SPECIFICATIONS

MODEL : DD400P
HEIGHT : 787mm
WIDTH : 552mm
DEPTH : 487mm
WEIGHT : 31 Kg
DRY AIRFLOW : 370 M³/HR
WET AIRFLOW : 150 M³/HR
POWER SUPPLY : 230V, 1 ph, 50Hz
POWER 2.2 kW (max)
FINISH : Epoxy Coated

DEHUMIDIFICATION CAPACITY
(AT 28°C AND 60% RH)| 34 lt/day
NOISE| 67dB(A)

INSTALLATION

POSITIONING: **

**

The DD400P is designed for indoor use. Position the dehumidifier unit in the center of the room to be conditioned if at all possible.

NOTE: Both the air inlets and outlets of the dehumidifier unit must have clear space around them and not be obstructed in anyway. For correct installation and operation the unit inlet and outlet must have a clearance of 0.5M from all adjacent surfaces and or structures.

DUCT CONNECTION

The wet air outlet from the dehumidifier must be exhausted to outside of the room being dried by means of a suitable duct. All duct connections to the dehumidifier have been designed for connections to standard size ducts. The duct should be as short as possible to reduce the risk of condensation of the wet air. The duct should slope downwards away from the unit to stop any condensed water from flowing back into the unit.

The dry air outlet is also provided with a means of attaching a duct. This can be used to direct the air towards more severe damp patches.

WIRING:

WARNING THIS APPLIANCE MUST BE EARTHED

The DD400P is provided with a standard plug and is designed to operate from a 13 Amp supply.
IMPORTANT ­ The wires in the mains lead are coloured in accordance with the following code:
GREEN & YELLOW…………EARTH BLUE………………………….NEUTRAL BROWN……………………….LIVE
If the supply cord is damaged it must be replaced by qualified Ebac Industrial Products Ltd personnel or other similar qualified persons in order to avoid hazard.

OPERATION

The electrical controls are located on the front of the rear. They are:

  • ON / OFF Switch
    0 Dehumidifier OFF
    I Dehumidifier ON

  • Digital Humidistat
    Setting the Digital Humidistat
    The Digital Humidistat is factory preset to give the optimum level of control. Only adjustment of the desired set point is required.
    During normal operation, the display shows the current % Relative Humidity within the space being conditioned.
    The required humidity level can be set as follows:

  • Press the “S” button once to access the set point

  • Press the or button to change the display to the desired Humidity level

Press the “S” button again to save the set point ­ The control returns to displaying the current % Relative Humidity

  • An hour counter is provided to display the total time the unit has been in operation

To start the dehumidifier, turn the On / Off switch to position I. Then set the required humidity set point as stated above. The process fan will start immediately and if the digital humidity set point is lower than the room humidity then after a slight delay the regeneration fan will start ­ air can be felt blowing from the air outlets and the heater will come on. The unit will operate at this setting until the required humidity level is reached at which point the heaters and regeneration fan only will switch off. The unit will continue to monitor the humidity level and reactivate the heaters and regeneration fan as required. It will continue this cycle until the unit is switched off.

Note. The DD400P is controlled by an electronic circuit board and uses dual PTC (positive temperature coefficient) heater technology to provide the heat necessary to “reactivate” the rotor. To ensure safe start up, the heaters are switched on in stages ­ the first heater is switched on at start up and the remaining heater switched on after 10 seconds.

AIR MOVING SYSTEM:
The DD400P is a dual fan system with dedicated fans for the “Process” air and “Regeneration” air flows. As the air passes over the rotor, it will be heated as a result of the regeneration cycle. The air leaving the unit will be hotter than the air entering
During normal operation some parts of the dehumidifier may become hot. This is normal.

HIGH TEMPERATURE CUT OUT:
The DD400P dehumidifier has been designed to work in ambient conditions of -20ºC to +40ºC. Should the temperature in the room become excessive an overheat protector will operate, switching off the PTC heaters. The fans and drive motor will continue to operate. This is a manual reset device. Prior to resetting the protector, check that the dehumidifier is installed correctly and the ambient temperature does not exceed 40°C. See repairs section for details on resetting device.

DEHUMIDIFICATION CAPACITY
Approximate capacity in Kg/h at different inlet process air temperature and relative humidity (%)

Dehumidification Capacity Kg/h

EIP-DD400P-230v-Portable-Desiccant-Dryer-01

SAFETY

WARNING-
DO NOT ALLOW CHILDREN TO PLAY WITH OR AROUND THE UNIT.
ENSURE THE UNIT IS INACCESIBLE TO CHILDREN WHEN NOT ATTENDED.
DO NOT USE THIS UNIT IN AN ENVIRONMENT CONTAINING FLAMMABLE FUMES
DO NOT USE THIS UNIT IF THE CABINET OR POWER CORD IS DAMAGED
DO NOT INSERT OBJECTS INTO ANY OF THE GRILLES ON THE MACHINE
DO NOT COVER OR OBSTRUCT AIRFLOW FROM THE GRILLES
DO NOT OPERATE THE UNIT WITH THE COVERS REMOVED DO NOT ATTEMPT ANY REPAIRS SHOULD THE UNIT FAIL TO OPERATE DO NOT STAND ON THE UNIT DO NOT LIFT THE UNIT WHEN SWITCHED ON DO CHECK THE PLUG ON THE EQUIPMENT MATCHES THE SUPPLY DO USE THE UNIT FOR THE PURPOSE FOR WHICH IT WAS DESIGNED DO ENSURE THE POWER CORD AND SUPPLY IS EARTHED CORRECTLY DO USE A RESIDUAL CURRENT DEVICE “RCD” WHERE
POSSIBLE DO KEEP THE UNIT DRY. NEVER USE A HOSE OR PRESSURE WASHER TO CLEAN THE UNIT.

ROUTINE SERVICE & REPAIR

WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE
SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED
PERSON.
SWITCH OFF THE DEHUMIDIFIER APPROXIMATELY 15 MINUTES PRIOR TO REMOVING ANY PANELS, ALLOWING
THE HEATER TO COOL DOWN

To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows:

  • We recommend that the filters are checked at least once a month. Intervals for cleaning or replacement of filters will depend on the installation

  •  Never operate the dehumidifier without the filters, as the rotor can be damaged by dust.
    To carryout the following, it is necessary to remove the side cover panels.
    This machine should be serviced by qualified Ebac Industrial Products Ltd personnel or other persons having technical competence in servicing electrical equipment following the instructions in this Service Manual.

  • The rotor is maintenance free. However, should it be necessary to clean the rotor, compressed air should be used to carefully blow dirt from the rotor.

  • The PTC heaters are maintenance free. However should it be necessary to clean the heaters, compressed air should be used to carefully blow dirt from the heaters.

  • Check that the fans are firmly secured and that the fan rotates freely.

  •  Check all wiring connections.

  • Check the belt tensioning at regular intervals. Adjust when needed by loosening the four bolts holding the drive wheel and rotating the drive motor until correct tension is achieved.

  • The overheat protector is located inside the unit, above the rotor. To reset this device press the red button.

  • Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part.

IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC INDUSTRIAL PRODUCTS LTD SERVICE CENTER PRIOR TO CONTINUED
OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE.

TROUBLESHOOTING

SYMPTOM CAUSE REMEDY
Filter clogged Clean or replace filters
Little or no dehumidification capacity No regeneration heat Reduced

airflow
No rotation of Rotor| Check PTC / OHP Check fans / duct
Check belt tension / drive motor
| Air leakage| Check sealing
Dehumidifier does not start| No power
Correct switch setting| Check fuse
Check On / Off switch
| Loose electrical wiring| Check wiring diagram – fault find & repair
| Drive belt slipping| Check belt tension
Rotor does not rotate| Drive belt broken
Rotor jammed| Replace drive belt
Check center shaft, rim of rotor
| Drive motor faulty| Check supply /Replace motor
No Dry or Wet Air Airflow| Filter clogged Fan faulty
Ducts blocked| Clean or replace filters Check supply / fan
Check duct for obstruction
Low current displayed on ammeter| Low reactivation airflow
PTC faulty| Check air path for restriction
Check PTC / OHP
Noisy| Fan loose
Loose fastenings| Check fans secured firmly
Tighten all fastenings

SPARE PARTS LIST

DESCRIPTION PART NUMBER
Process Air Fan Motor 3040251
Capacitor for Process Air Fan Motor 3030835
Process Inlet Filter 2050029
Regeneration Air Fan Motor 3040250
Capacitor for Regeneration Air Fan Motor 3030834
Regeneration Inlet Filter 2064032
Drive Motor 3040249
Capacitor for Drive Motor 3030832
Pulley 3050552
Pulley Belt 3050551
PTC Heater 3031625
Overheat Protector 3477026
Desiccant Wheel 3020706
PCB Controller 1619600
Mains Cable 2029217
On / Off Switch 3035914
Hour Counter 3030778
Humidity Controller 3031526

Spare parts available online
www.EIPLDIRECT.com

WARNINGS
This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid hazard.

UK Head Office
Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD
Tel: +44 (0) 1388 664400
Fax: +44 (0) 1388 662590
www.eipl.co.uk
sales@eipl.co.uk

American Sales Office
Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA
Tel: +01 757 873 6800
Fax: +01 757 873 3632
www.ebacusa.com
sales@ebacusa.com

German Sales Office
Ebac Industrial Products Ltd. Gartenfelder Str. 29-37 Gebäude 35 D-13599, Berlin Germany
Tel: +49 3043 557241
Fax: +49 3043 557240
www.eip-ltd.de
sales@eip-ltd.de

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals