Lenovo 00YA800 Enterprise Mainstream Flash Adapters Owner’s Manual

June 3, 2024
Lenovo

io3 Enterprise Mainstream Flash Adapters
Product Guide (withdrawn product)
Owner’s Manual

00YA800 Enterprise Mainstream Flash Adapters

Engineered for application acceleration, the Lenovo io3 Enterprise Mainstream PCIe Flash Storage Adapters can help deliver higher performance than typical solid-state devices at a fraction of the cost and space, which makes them a perfect fit for a broad range of applications, including database and cloud applications, big data analytics, and hyper-scale data center workloads.
Delivering high speed, low latency, and high efficiency, this new third- generation line of flash adapters brings scalable and optimized performance to distributed scale-out architectures at low cost. These adapters are designed primarily for servers and computing appliances to maximize compute efficiency while providing the added benefits of lower power and cooling costs, low management impact, and smaller storage footprints.
The io3 6.4TB Enterprise Mainstream Flash Adapter is shown in the following figure.
Lenovo 00YA800 Enterprise Mainstream Flash Adapters - Figure
1 Did you know?
The io3 Enterprise Mainstream Flash Adapters use flash memory as their storage medium, which contains no moving parts and does not have the issues that are associated with vibration, noise, and mechanical failure. The adapters are built as block devices on a PCIe bus with advanced wear-leveling, ECC protection, and chip-level fault tolerance, which provides exceptional reliability and efficiency.
With a capacity of up to 6.4 TB per PCIe adapter and a write latency of 15 µs, the io3 Enterprise Mainstream Flash Adapters are an excellent choice for application acceleration with analytics, database, VDI, cloud, hyperscale, and big data applications.
Click here to check for updates

Part number information

The following table lists the ordering information for the adapters.
Withdrawn: All adapters are now withdrawn from marketing.
Table 1. Ordering information

Part number Feature Description
00YA800 AT7N io3 1.25TB Enterprise Mainstream Flash Adapter
00YA803 AT7P io3 1.6TB Enterprise Mainstream Flash Adapter
00YA806 AT7Q io3 3.2TB Enterprise Mainstream Flash Adapter
00YA809 AT7R io3 6.4TB Enterprise Mainstream Flash Adapter

The part numbers for the adapters include the following items:

  • A PCIe Flash Adapter with 3U full-height bracket attached
  • Separate 2U low-profile PCIe bracket (1250GB, 1600GB, and 3200GB adapters only)
  • USB Key with documentation
  • Quick Install Guide
  • Important Notices document
  • Warranty Flyer

Features

The io3 Enterprise Mainstream Flash Adapters are based on the SanDisk Fusion ioMemory SX350 adapters. They use cost-effective Multi-Level Cell (MLC) NAND flash memory as the basic building block of solid-state storage and contain no moving parts, so they are less sensitive to issues that are associated with vibration, noise, and mechanical failure. These adapters are standard PCIe devices and appear to the operating system as local block storage. io3 Mainstream adapters have advanced wear-leveling, ECC, and chip-level fault tolerance, which provides exceptional reliability and efficiency.
The io3 Enterprise Mainstream Flash Adapters can deliver the fast, scalable performance for general-purpose workloads at low latency that is required for webscale and cloud
environments. The following typical applications require ultrahigh I/O performance:

  • Large-scale transaction processing
  • Cloud computing
  • Content distribution
  • On-demand streaming
  • Data warehousing
  • Business intelligence and analytics
  • Decision support
  • Online Transaction Processing

The io3 Enterprise Mainstream Flash Adapters have the following features:

  • Technology:
    ο Up to 6.4 TB of solid-state storage in an industry-standard PCIe form factor.
    ο High-density design with cost-effective MLC NAND technology that reduces storage footprint.
    ο Functions as a PCIe storage and controller device. The operating system sees a block device.

  • Performance:
    ο Improved performance over the previous generation io3 Enterprise Value adapters
    ο High-speed, low latency, consistent, and scalable I/O performance
    ο Access latency can be as low as 15 µs
    ο Up to 2.8 GBps/2.2 GBps of sustained sequential read/write throughput
    ο Up to 345,000/385,000 random read/write IOPS that uses 4 KB data blocks

  • Reliability:
    ο Advanced wear leveling
    ο ECC protection
    ο Adaptive Flashback redundancy for RAID-like chip protection with self- healing capabilities

  • Monitoring and management:
    ο Power consumption
    ο Thermal information
    ο Flash wear-out

Note: These adapters cannot be used as bootable devices.

Technical specifications

The following table lists the technical specifications for the io3 Enterprise Mainstream Flash Adapters.
Table 2. Technical specifications

Specification 1.25 TB 1.6 TB 3.2 TB 6.4 TB
Part number 00YA800 00YA803 00YA806 00YA809
Interface PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8 PCIe 2.0 x8
Form factor Half-height, half
length Half-height, half
length Half-height, half
length Full height, half

length
Capacity| 1250 GB| 1600 GB| 3200 GB| 6400 GB
Endurance (total bytes written, TBW)| 4 PB| 5.5 PB| 11 PB| 22 PB
Random read IOPS (4 KB blocks)| 225,000| 270,000| 345,000| 340,000
Random write IOPS (4 KB blocks)| 345,000| 375,000| 385,000| 385,000
Sequential read throughput| 2.8 GBps| 2.8 GBps| 2.8 GBps| 2.8 GBps
Sequential write throughput| 1.3 GBps| 1.7 GBps| 2.2 GBps| 2.2 GBps
Read access latency| 79 µs| 79 µs| 79 µs| 79 µs
Write access latency| 15 µs| 15 µs| 15 µs| 15 µs
Power consumption (Max)| 19.5 W| 22 W| 24 W| 24.5 W

The key difference between io3 Enterprise Mainstream and Enterprise Flash Storage devices is their endurance (or lifetime); that is, how long they can perform write operations because solid-state devices have a finite number of program/erase (P/E) cycles. Enterprise Mainstream PCIe Flash Adapters have a better cost/IOPS ratio but lower endurance compared to Enterprise PCIe Flash adapters.
Because of the difference in write endurance, the Enterprise Mainstream Flash Adapters are targeted for general-purpose workloads, and the Enterprise Flash Adapters are targeted for mixed read- and write-intensive workloads. Solid- state device writes endurance often is measured by the number of P/E cycles that the drive incurs over its lifetime, which is listed as the total bytes of written (TBW) data in the device specification.
The TBW value that is assigned to a flash storage adapter is the TBW data (based on the number of P/E cycles) that an adapter can be guaranteed to complete (the percentage of remaining P/E cycles is equal to the percentage of remaining TBW). The Lenovo warranty for the flash storage adapter is limited to devices that have not reached the maximum guaranteed number of P/E cycles. Flash storage adapters that reach this limit might fail to operate according to their specifications. Because of such behavior, careful planning must be done to use the adapters in the application environments to ensure that the TBW of the adapter is not exceeded before the end of the required life expectancy.
Writes are tracked and reported by the adapter’s management utility and might be affected by application writes, data patterns, and maintenance designed to maximize data integrity.
Server support
The following tables list the server compatibility information for the io3 Enterprise Mainstream Flash Adapters.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Table 3. Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processorsLenovo 00YA800 Enterprise Mainstream Flash Adapters - Table
1 This adapter cannot be factory installed; it is supported as a field-installable option only. The server cannot be shipped with this adapter installed.
Support for servers with Intel Xeon v3 processors
Table 4. Support for servers with Intel Xeon v3 processorsLenovo 00YA800
Enterprise Mainstream Flash Adapters - Table 2
This adapter cannot be factory installed; it is supported as a field-installable option only. The server cannot be shipped with this adapter installed.
Support for servers with Intel Xeon v2 processors
Table 5. Support for servers with Intel Xeon v2 processorsLenovo 00YA800
Enterprise Mainstream Flash Adapters - Table 3* This adapter cannot be factory installed; it is supported as a field-installable option only. The server cannot be shipped with this adapter installed.
Support for Flex System compute nodes
The adapters are supported in the following Flex System compute nodes when installed in an attached PCIe Expansion Node.
Table 6. Support for Flex System servers.Lenovo 00YA800 Enterprise
Mainstream Flash Adapters - Table 4See the following ServerProven website for the latest compatibility information for System x servers:
http://www.lenovo.com/us/en/serverproven/
For further information about server compatibility, see this support page:
https://support.lenovo.com/us/en/documents/serv-io3

Operating system support

The io3 Enterprise Mainstream Flash Adapters support the following operating systems:

  • Microsoft Windows Server 2008 R2
  • Microsoft Windows Server 2012
  • Microsoft Windows Server 2012 R2
  • Red Hat Enterprise Linux 6 Server x64 Edition
  • Red Hat Enterprise Linux 7
  • SUSE LINUX Enterprise Server 11 for AMD64/EM64T
  • SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
  • SUSE Linux Enterprise Server 12
  • SUSE Linux Enterprise Server 12 with XEN
  • VMware vSphere 5.5 (ESXi)
  • VMware vSphere 6.0 (ESXi)

Note: These adapters cannot be used as bootable devices.
For more information about the specific supported versions and service packs, see the following ServerProven web page:
http://www.lenovo.com/us/en/serverproven/xseries/storage/mcmatrix.shtml
On the ServerProven page, click the check mark that is associated with the server in question to see more information about the operating system support.
Warranty
The adapters carry a 1-year, customer-replaceable unit (CRU) limited warranty. When installed in a supported Lenovo server, these adapters assume the system’s base warranty and any warranty upgrade.

Physical specifications

The 1.25 TB, 1.6 TB, and 3.2 TB io3 Enterprise Mainstream Flash Adapters have the following physical specifications:

  • Dimensions and weight (approximate):
    ο Height: 17 mm (0.7 in.)
    ο Width: 69 mm (2.7 in.)
    ο Depth: 167 mm (6.6 in.)
    ο Weight: 152 g (0.3 lb)

  • Shipping dimensions and weight (approximate):
    ο Height: 65 mm (2.6 in.)
    ο Width: 245 mm (9.6 in.)
    ο Depth: 225 mm (8.9 in.)
    ο Weight: 421 g (0.9 lb)
    The 6.4 TB Enterprise Mainstream Flash Adapter has the following physical specifications:

  • Dimensions and weight (approximate):
    ο Height: 17 mm (0.7 in.)
    ο Width: 112 mm (4.4 in.)
    ο Depth: 167 mm (6.6 in.)
    ο Weight: 212 g (0.5 lb)

  • Shipping dimensions and weight (approximate):
    ο Height: 65 mm (2.6 in.)
    ο Width: 245 mm (9.6 in.)
    ο Depth: 225 mm (8.9 in.)
    ο Weight: 481 g (1.1 lb)

Operating environment
The adapters are supported in the following environment:

  • Temperature (operational): 0 – 55 °C (32 – 131 °F) at 0 – 3,048 m (0 – 10,000 ft)
  • Relative humidity: 5 – 95% (non-condensing)
  • Maximum altitude (operational): 3,048 m (10,000 ft)

Agency approvals
The io3 Enterprise Mainstream Flash Adapters conform to the following regulations:

  • FCC Title 47, Part 15 Subpart B, Class A
  • CAN ICES-3 (A) NMB-3 (A)
  • EN 55022: 2010
  • EN 61000-3-2: 2006 plus A1:2009 and A2:2009
  • EN 61000-3-3: 2008
  • EN 55024: 2010
  • VCCI V-3/2013.04 Class A & EN 55022: 2010 Class A
  • ANSI C63.4: 2009
  • BSMI CNS 13438: 2006 Class A
  • EN 55022 (2006) A1 (2007) Class A
  • AS/NZS CISPR 22: 2009 plus A1:2010
  • MSIP-REM-FIO-ioScale3
  • EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 and IEC 60950-1:2005 A1:2009
  • RoHS Directive 2011/65/EU
  • Low Voltage Directive 2006/95/EC
  • EMC Directive 2004/108/EC
  • REACH Directive 1999/45/EC and Regulation (EC) 1907/2006
  • WEEE Directive 2002/96/EC

Related publications and links
For more information, see the following web pages and documents:

Related product families
Product families related to this document are the following:

Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only the Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering the subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
The U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimers of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, LP0058, was created or updated on February 9, 2018.
Send us your comments in one of the following ways:

This document is available online at https://lenovopress.lenovo.com/LP0058.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Flex System
ServerProven®
System x®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.

io3 Enterprise Mainstream Flash Adapters (withdrawn product)
Lenovo 00YA800 Enterprise Mainstream Flash Adapters -
logo2

Documents / Resources

| Lenovo 00YA800 Enterprise Mainstream Flash Adapters [pdf] Owner's Manual
00YA800, Enterprise Mainstream Flash Adapters, 00YA800 Enterprise Mainstream Flash Adapters, Mainstream Flash Adapters, Flash Adapters, Adapters
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lenovo User Manuals

Related Manuals