Waxman Energy T4 Cable Couplers Instruction Manual
- June 5, 2024
- Waxman Energy
Table of Contents
- T4 CONNECTOR PARTS
- T4 CONNECTOR SPECIFICATIONS
- T4 INSTALLATION PARAMETERS
- SAFETY PRECAUTIONS
- T4 FIELD TOOLKIT
- CONNECTOR & WIRE ASSEMBLY STEPS
- THE CORRECT CONNECTION
- DISCONNECTING THE CONNECTORS
- LIST OF FORBIDDEN CHEMICAL SUBSTANCES
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Waxman Energy T4 Cable Couplers Instruction Manual
T4 CONNECTOR PARTS
Item | Part Name |
---|---|
1 | PV Cable |
2 | Male Pin Contact (-) |
3 | Male Connector (-) |
4 | Female Socket Contact (+) |
5 | Female Connector (+) |
T4 CONNECTOR SPECIFICATIONS
ELECTRICAL DATA:
Connector Specification | T4 |
---|---|
Rated Voltage | IEC 1000 VDC / UL 1500 VDC |
IEC 1500 VDC / UL 1500 VDC
Rated Current| 41A (4 mm²) / 40A (12 AWG)
__48A (4 mm²) / 40A (12 AWG)
50A (6 mm²) / 55A (10 AWG)
54A (6 mm²) / 55A (10 AWG)
Contact Resistance| ≤ 0.25 mΩ
Pollution Degree| ClassⅡ
Protection Class| ClassⅡ
Protection Degree| IP68
Fire Resistance| UL 94-V0
Temperature Range| – 40 °C ~ + 90 °C
Rated Impulse Voltage| 16 kV
MECHANICAL DATA:
Connector Specification | T4 |
---|---|
Cable Specification | IEC: 4 mm² / 6 mm² |
UL: 12 AWG / 10 AWG
Connector System| Φ 4.0 mm
Contact Material| Copper, Tin-plated
Type of Termination| Crimping
Locking System (UL)| Locking type
T4 INSTALLATION PARAMETERS
Article| Cable Outside Diameter (OD)| Picture| Required Torque to Lock|
Reference Gap
---|---|---|---|---
Male Connector (-)
| 4.3mm – 6.6mm 6.7mm -7.5mm| | ****
3.0 N•m ~ 4.0 N•m
| ****
0.5< gap ≤ 1.5mm
Female Connector (+)
| | ****
3.0 N•m ~ 4.0 N•m
| ****
0.5 < gap ≤ 1.5mm
Male
Pin Contact (-)
| ****
——
| | ****
——
| ****
——
Female Socket Contact (+)| ****
——
| | ****
——
| ****
——
SAFETY PRECAUTIONS
Products must be assembled and installed by qualified personnel, ensuring all
safety regulations are followed. For protection against electric shock, please
ensure the system is not energized during installation. Do not disconnect
under load.
Ensure that the AC and the DC sides are both disconnected and the system is
not energized before disconnecting.
Use only the tools and components listed in this installation manual. Follow the instructions as stated in this manual. Do not alter or willingly damage the product in anyway.
- Sealing cap must be used on disconnected connectors to prevent dust ingress.
- Connectors are IP68-rated when mated.
- Do not place connectors directly on roof surface.
CAUTION:
The exposure to or direct contact with chemicals or oils of T4 product may
cause corrosion, degradation of performance, or cracking of the product, thus
such exposure or direct contact should be strictly prohibited during the
process of product manufacturing, transportation, installation and
application.
It is the user’s responsibility to validate any chemical that may come into
contact with or used in any of the processes mentioned above, to ensure that
such chemical will not affect the performance of T4 products.
T4 FIELD TOOLKIT
CAUTION:
Any T4 products can be intermated with each other.
CVAUTION:
Interconnection of different connector types/brands with T4 is not allowed.
CAUTION:
Recycling and all other types of comparable disassembly of the above mentioned
products have to be performed by a qualified waste management company, in
compliance with national and local waste management regulations.
PARTS INCLUDED IN FIELD TOOLKIT:
Wire stripper tool
Type | Crimping Range |
---|---|
2.5/14 | 2.5 mm2 |
4.0/12 | 4.0 mm2 |
6.0/10 | 6.0 mm2 |
Wire crimping tool
Mark | Riveting Range |
---|---|
2.5/14 | 2.5 mm2 |
4.0/12 | 4.0 mm2 |
6.0/10 | 6.0 mm2 |
Crimping tool accessory – part of wire crimping tool
Cutting pliers
Wrench
1 set = 2 pieces
CONNECTOR & WIRE ASSEMBLY STEPS
STEP 1:
VISUAL INSPECTION OF CONNECTOR
FEMALE CONNECTOR
a. Sealing ring should fit cleanly in the slot and not be warped or distorted.
b. The two plastic clasps should be intact.
c. Female connectors should not be
obstructed by foreign objects or water.
d. Plastic components should not be cracked.
e. No damage should be visible on the cable.
MALE CONNECTOR
a. Male connector should not be obstructed by foreign objects or water.
b. Plastic components should not be cracked.
c. No damage should be visible on the cable.
STEP 2:
STRIP THE INSULATION OFF THE CABLE
Using the wire stripper tool, remove the insulation from the cable. Ensure that 7.5 mm of cable are exposed, and that the wire strands are not damaged during the process of stripping the insulation.
STEP 3:
CRIMP THE CONTACT
Place the contact around the bare section of the stripped wire. Crimp the contact using the wire crimping tool. The crimped contact should withstand pull forces of ≥310 N.
STEP 4:
INSERT THE CONTACT
Push the crimped contact back into the connector until you hear a click. Lightly pull the wire to ensure the metal components of the connector are engaged.
STEP 5:
TIGHTEN THE CABLE GLAND
First, tighten the gland by hand. Then use the disconnect tools to tighten the gland to the connector until it clicks, ensuring that it is locked. When tighteng the male connector, please use aligner available on the disconnect tool in order to ensure the pin is not skewed.
STEP 6:
CONNECTING THE CONNECTORS
Check the appearance of the connectors before connecting them together. The sealing ring should be in the slot with no warping or distortion. The plastic clasps should not be damaged or broken. The connectors should be free of moisture and foreign objects. Plastic parts should not be cracked. Wire should not be frayed or damaged. When attaching, insert the connectors into each other until you hear a “click”. Once attached, gently pull on the connectors to ensure they are firmly connected and cannot be easily disconnected by hand.
STEP 7:
VISUAL INSPECTION OF THE CONNECTION
To check the connection, ensure that you cannot see the sealing ring. The gap between the connectors should be less than 0.5 mm.
THE CORRECT CONNECTION
DISCONNECTING THE CONNECTORS
The mated connectors can only be disconnected by using the disconnect tools.
Insert the clasp of the disconnect tool in the slots of the male connector, and the female connector will automatically get disconnected .
AMENDED EDITIONS AND DATES
Rev 1.0 was released in November 2016.
Rev 1.1 was amended and released in May 2017.
Rev 1.2 was amended and released in Sep 2017.
Rev 1.3 was amended and released in Apr 2019.
Rev 1.4 was amended and released in Sep 2019.
Rev 1.5 was amended and released in Apr 2020.
Rev 1.6 was amended and released in Jun 2020.
Rev 1.7 was amended and released in Mar 2021.
Rev 1.8 was amended and released in Oct 2021.
Rev 1.9 was amended and released in Nov 2021.
Rev 2.0 was amended and released in Mar 2022.
The technical descriptions herein are only for reference when using these products.
LIST OF FORBIDDEN CHEMICAL SUBSTANCES
WARNING
Users of T4 products should prevent the exposure of T4 products to any of the following chemical substances listed below. These chemicals may cause corrosion, degradation of performance, or cracking of product and might lead to potential safety issues in applications.
Lists of all known chemicals:
Class | Chemical Name |
---|---|
Commonly used chemicals | Food release spray, Herbicide, Insecticide, Grease, |
Lubricate oil, Rust inhibi- tors, REMA New punch oil, Stamping oil, Engine
Oil, Banana Oil, WD-40, Oily sealing agent, Doduconta B25 Kontaktol, Evabrite
S, Virex TB, Suma Lima L3, Suma Rinse, Detergent, Plasticizer, Spray
cleaner8188, CM-31S, REMA cleaner oil, DX-1, CH1160, Dry lubricating oil,
Paint remover, hydraulic oil, Special glue quick solvent, Gasification rust
inhibitor, Dehumidifying anti-rust lubricant, Cutting oil.
Disinfectants/Cleaners| Betadine, Cide, Ammonia, Organic Ammonium Chloride,
Hydrogen peroxide, Bleach, Saline, Detergent.
Cosmetics| Hand cream, Sunscreen, Lipstick, Sun screen, Makeup remover.
Oils| Die Cut (OELHELD), Machine Oil KV46 (Nippon Oil), Infeld stamping oil.
Edible| Corn oil, Cola, Light syrup, Rapeseed oil, Blend oil, Olive oil,
Castor oil, Soybean oil, Coconut oil.
Acid, Alkali, Salt| Ammonium hydrogen, Potassium hydroxide, Salt acid,
Sulfuric acid, Nitric acid, Phosphoric acid, Acetic acid, Ammonia, Sodium
hydroxide.
Grease| Vaseline, Molykote EM-50L (Dow Corning), Molykote PG-641 (Dow
Corning).
Mould Release Agent| Pelicoat S-6 (Chukyo-Kasei).
Binder| Chemlok (LORD).
Alcohols| Ethylene glycol, Amyl alcohol, Ethanol, Isopropanol, Isopropyl
alcohol (IPA).
Fatty hydrocarbons| Heptane,Hexane,Cyclohexane,Liquid paraffin.
Halogenated hydrocarbon| Freon,Carbon tetrachloride,Trichloromethane, Virex
256.
Ketone| Methyl Ethyl Ketone (MEK),Acetone,Methyl ethyl ketone.
Aromatic Hydrocarbon| Toluene,Xylene,Cresol.
Other, Organic solvent| Oleic acid C18H34O2,Nonanal C9H18O,Oleic
acidC9H18O2,Ethyl acetate, Butyl acetate,Tributyl phosphate,Kerosene,Gasoline,
Varnish,Esters,Ethers,Amines,Glacial acetic acid,Print ink,3M.
Adhesion sealant| APF125 (Wacker Chemical), 3M adhesive, Avancis adhesive.
Remarks:
For any chemical not listed above that may come into contact with any T4
product,it is the user’s responsibility to validate that such chemical will
not affect the performance of T4 products.