lakepeople G103-P-Mk-II PHONE-AMP User Manual
- June 4, 2024
- lakepeople
Table of Contents
- lakepeople G103-P-Mk-II PHONE-AMP
- General Safety Instructions
- The Earth / Grounding Concept
- Mind the SECURITY INSTRUCTIONS!
- Connection / Connectors for Analog Signals
- Operation PHONE-AMP G103 Mk II
- FOLLOW THE SAFETY INSTRUCTIONS
- DISPOSAL
- Technical Data PHONE-AMP G103 Mk II
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
lakepeople G103-P-Mk-II PHONE-AMP
General Safety Instructions
WARNING
For your protection, please read the following:
Water, Liquids, Moisture:
This appliance should not be used near water or other sources of liquids.
Care should be taken so that objects do not fall and liquids are not spilled
into the enclosure through openings.
Power Sources:
The appliance should be connected to a power supply only of the type described
in the operating instructions or as marked on the appliance.
Grounding:
Care should be taken that this appliance is operated only properly grounded.
Power Cord:
Power supply cords should be routed so that they are not likely to be walked
on or pinched by items placed upon or against them, paying particular
attention to cords at plugs, convenience receptacles, and the point where they
exit from the appliance. This unit is equipped with a 3-pole IEC/CEE mains
connector and comes with different power cables for different regions.
In some countries this unit must be operated with a mains adaptor, supplied by
the owner.
Please refer to the table below to connect a mains plug:
OVERVIEW: POWER CORD FUNCTION AND COLORS
Leiter / CONDUCTOR| Farbe| COLOR| Alternativ| Alternativ
L| Phase| LIVE| Braun| BROWN| Schwarz| BLACK
N| Null| NEUTRAL| Blau| BLUE| Weiss| WHITE
E| | | Erde| EARTH GND| Grün-Gelb| GRN+YLW| Grün| GREEN
U.K. Mains Plug Warning:
A moulded mains plug that has been cut off from the cord is unsafe. Discard
the mains plug at a suitable disposal facility.
NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT MAINS PLUG
INTO A 13 AMP POWER SOCKET.
Do not use the mains plug without the fuse cover in place. Replacement fuse
covers can be obtained from your local retailer. Replacement fuses are 13 amps
and MUST be ASTA approved to BS 1362.
Mains Fuse:
The mains fuse of this appliance is soldered in place and only accessible from
the inside!
A burnt fuse may be an indicator of internal problems and should be replaced
during a qualified servicing or repairing works!
Switchable Power Supply:
Connect this unit only to the power source indicated on the equipment rear
panel to ensure safe operation!
This unit is intended to be used with a mains supply of 230 V AC.
Service / Repair:
To reduce the risk of fire or electric shock, the user should not attempt to
service the appliance beyond that described in the operating manual. All other
servicing or repair should be referred to qualified personal!
Electromagnetic Compatibility
This unit conforms to the Product Specifications noted as Declaration of
Conformity at the end of this manual. Operation is subject to the following
conditions:
- this device may not cause harmful interferences
- this device must accept any interference received, including interference that may cause undesired operation
- this device must not be operated within significant electromagnetic field
The Earth / Grounding Concept
General GROUND-LIFT Jumper (see also page 22/23)
Mind the SECURITY INSTRUCTIONS!
Ex-works this jumper is set to the LIFT position.
The internal ground potential is normally connected to the external earth
reference at this point and is lifted by means of this jumper.
As a result, the interconnection for DC voltages and lower frequencies (< 150
Hz) will be cut. Higher frequencies will be bled off to earth potential
through the RC filter. The LIFT position may be helpful in case of hum or
jitter caused by different ground/earth potentials.
Unfortunately, there is no general recommendation how to solve hum and jitter
problems – or even minimize them. The best way to succeed is to check
different options! Electrical safety is always ensured, since the earth
conductor is permanently connected to the enclosure!
When the ex-work settings are altered, EMC problems might occur, These are
in the field of the user´s responsibility!
Connection / Connectors for Analog Signals
CAUTION
THE HIGH OUTPUT LEVELS ACHIEVABLE WITH THIS UNIT MAY DAMAGE YOUR HEARING OR
THE HEADPHONES
IF OPERATED CARELESSLY!
Operation PHONE-AMP G103 Mk II
GENERAL
The PHONE-AMP G103 Mk II is a stereo headphone amplifier. Different to most
comparable models the overall gain may be altered with the aid of internal
jumpers to better match specific headphone characteristics. Due to this
technique, this headphone amplifier is able to drive nearly all existing
headphones from 8 … 600 ohms load impedance.
Because of its noise- and THD-optimized circuitry layout, PHONE-AMP G103 Mk II
covers high quality demands.
HINT:
Ex works PHONE-AMP G103 Mk II is always set to +6 dB gain mode.
In spite of its compact dimensions, PHONE-AMP G103 Mk II offers optimum
flexibility and high power.
Reliability even under rough or improper handling conditions has been another
important goal of development.
Thus, the unit is absolutely long-term short-circuit proof.
In addition, the PHONE-AMP G103 Mk II is equipped with filters to prevent
overload by inaudibly low and high frequencies.
THE CASE
The case of PHONE-AMP G103 Mk II is made of black anodized aluminium,
including the front- and back panels.
This provides high mechanical stability and resistance against rough handling.
The cases surfaces are providing excellent electrical conductivity for optimum
EMC characteristics.
EARTH AND GROUND
The Case of PHONE-AMP G103 Mk II is connected to earth potential, the internal
ground potential may be connected to earth with the aid of a jumper. Ex works
the jumper is set to “LIFT” position.
(See page 14 “The earth/grounding concept and page 22/23 “Jumper settings”)
THE POWER SUPPLY
Mains is connected via a three-pin IEC/CEE socket and a matching three-wire
mains cable with Central Europe-type mains connector. The mains cable may vary
to fit the demands of different markets
The unit is factory-set to a mains voltage of 230 V AC.
Mains voltage may vary between 190 and 250 without any effect on flawless
operation. The built-in mains transformers provide the internal supply
voltages of approx. +/- 25 V.
THE MAINS FUSE
The 0,25 AT fuse is internally soldered in place on the power supply PCB.
ATTENTION !!
FOLLOW THE SAFETY INSTRUCTIONS
A blown fuse may refer to internal problems and should only been replaced during qualified servicing works!
THE INPUTS – STANDARD VERSION
For unbalanced signal injection gold plated RCA type connectors are provided
on the back of the case. They are marked:
“UNBALANCED IN“, “LEFT” and “RIGHT”.
THE INPUTS – PROFESSIONAL VERSION
The signal inputs on the rear are equipped with XLR female type sockets,
allowing balanced signal injection. They are marked:
“BALANCED IN”, “LEFT” and “RIGHT”
XLR pin out:
PIN 1| GND
PIN 2| (+) PHASE
PIN 3| (-) PHASE
POWER SWITCH
This switch activates the unit. Operation is indicated by the green “ON”-LED
below the switch.
VOLUME CONTROL
The “VOLUME”-control pot determines the headphone volume for both left and
right channel. With the aid of the internal gain setting the travel from the
volume control may be optimized.
Our recommendation: 12 o´clock for “normal“ listening.
HEADPHONES OUTPUTS
PHONE-AMP G103 Mk II offers two stereophonic headphone outputs.
Each is equipped with a standard 1/4″ phone jacks.
PHONE JACK PINOUT
Both stereophonic phone jacks are connected as follows:
THE AMPLIFIERS
The input signals are fed to special power op-amps which are made to work with
high supply voltages.
To match different headphone characteristics the overall gain may be altered
with the aid of jumpers.
(See page 22/23 “Jumper Settings” for details).
GAIN ADAPTION
For details see page 22/23 “Jumper Setting” The gain setting serves to adapt
the amplifier in a perfect way between the source and the headphones. On one
hand it may lower unwanted noise, on the other hand the travel of the volume
control may be optimized.
Around the input circuitry the gain may be set to -6 / 0 / +6 dB. Ex works the
unit is set to +6 dB, which may be sufficient for most applications. When high
sensitivity headphones are used, the jumpers may be set to 0 or
-6 dB gain to reduce gain.
The jumpers near the power op-amps allow a gain of +12 dB instead of 0 dB
which may be senseful for low efficiency headphones.
Because these jumpers will render the feedback gain, they will also cause a
higher noise level!
Ex works the jumpers are set to +6 dB gain!
DISPOSAL
Disposal of Old Electrical & Electronic Equipment – WEEE Regulation
(Applicable in the European Union and other European countries with separate
collection systems) This symbol on the product or on its packaging indicates
that this product shall not be treated as household waste. Instead, it shall
be handed over to the applicable collection point for the recycling of
electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent
potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product. The
recycling of materials will help to conserve natural resources. For more
detailed information about recycling of this product, please contact your
local Civic Office, your household waste disposal service or the shop where
you purchased the product.
Technical Data PHONE-AMP G103 Mk II
All measurement RMS unweighted, 20 Hz – 20 kHz
- Inputs G103 Mk-II-P: 2 x XLR female, electronically balanced
- Inputs G103 Mk II-S: 2 x RCA / Cinch, unbalanced
- Max. Input: +21 dBu
- Impedance: 10 kohms
- Amplifier Channels: 2 (Stereo)
- Overall Gain: +6 dB
- Variable Gain: -6 / 0 / +6 / +12 / +18 dB selectable
- Frequency range (-0.5dB): 5 Hz … 100 kHz
- Frequency range (- 3dB): 10 Hz … 250 kHz
- Dynamic Range
- 2 x 600R: > 127 dB (A-wtd)
- 2 x 100R: > 124 dB (A-wtd)
- Noise: < -102 dBu (A-wtd)
- THD+N (1kHz 2x 800mW / 100R): < 0,001% / < -100 dB
- Crosstalk: – 90 dB (1 kHz) / -70 dB (15 kHz)
- Output Impedance: < 0,1 Ohm
- Damping Factor (@ 50 Ohm): > 500
Max. output level:
1kHz / < 0.1% THD+N
Rl (2x) | Ua / V | Pa / mW / Channel |
---|---|---|
600 | 14,3 | 340 |
300 | 13,2 | 580 |
100 | 10,2 | 1050 |
50 | 8,0 | 1280 |
32 | 5,7 | 1000 |
16 | 2,7 | 440 |
General
Supply Voltage: 230 V AC / 6 Watt
Case: Aluminium
Front / Back: Aluminium
Case Dimensions: 105 x 42 x 160 mm (WxHxD)
Overall Dimensions: 108 x 45 x 185 mm (WxHxD)
We herewith declare that the following unit:
Name : PHONE-AMP G103 Mk II
Serial No: – all –
Is in conformity with the following EU directives:
2014/35/EU Low voltage directive
20014/30/EU EMC directive
EN 60065:2014/AC:2016 / JIS C6065:2016
Security directives for Audio-, Video- and similar electronic devices
2001/95/EG General Product Safety Directive
For verification of conformity with regards to electromagnetic compatibility
the following harmonized standards are applied:
EN 61000-6-1:2019 Generic emission standard (residential)
N 61000-6-2:2019 Generic emission standard (industrial)
EN 61000-6-3:2011+A1:2011 Generic immunity standard (residential)
EN 61000-6-4:2007+A1:2011 Generic immunity standard (industrial)
Product family standard for household appliances, multimedia equipment,
information technology equipment.
EN 55014-1:2017 / EN 55032 :2015
EN 55014-2:2015 / EN 55024 :2010+A1 :2015
2011/65/EU, RoHS Directive
2012/19/EU, WEEE Directive
(Member number DE 26076388)
For this declaration the manufacturer is responsible:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>