EMERSON 8092708 AVENTICS MU1 Oil Separator Instruction Manual

June 4, 2024
Emerson

EMERSON 8092708 AVENTICS MU1 Oil Separator

EMERSON-8092708-AVENTICS-MU1-Oil-Separator-image

About this documentation

These instructions contain important information for the safe and appropriate as-sembly and commissioning of the product.

Read these instructions carefully, especially chapter g 2. Notes on safety before you start working with the product.

Additional documentation
  1. Read and follow the operating instructions for the MU1 series maintenance unit.
  2. Also follow the instructions for the other system components.
  3. Please also observe the generally relevant, statutory and other binding regulations of European and national legislation and the national regulations for ac-cident prevention and environmental protection in your country.
Presentation of information

Warnings

In this document, there are warning notes before the steps whenever there is a danger of personal injury or damage to equipment. The measures described to avoid these hazards must be followed.

Structure of warnings

SIGNAL WORD

Hazard type and source
Consequences of non-observance

Precautions

Meaning of the signal words

CAUTION
Possible dangerous situation.
Failure to observe these notices may result in minor injuries or damage to property.

Symbols

Recommendation for the optimum use of our products.
Observe this information to ensure the smoothest possible operation.

Notes on safety

The product has been manufactured according to the accepted rules of current technology. Even so, there is a risk of injury or damage if the following general safety instructions and the specific warnings given in this instruction manual are not observed.

  1. Please read all these instructions carefully before working with the product.
  2. Keep these instructions in a location where they are accessible to all users at all times.
  3. Always include the operating instructions when you pass the product on to third parties.
Intended use

The product is exclusively intended for installation in a machine or system, or for combination with other components to form a machine or system. The product may only be commissioned after it has been installed in the machine/system for which it is intended.
Use is permitted only under the operating conditions and within the performance limits listed in the technical data. Only use compressed air as the medium.
The product is technical equipment and is intended for professional use only.
Intended use includes having fully read and understood these instructions, especially chapter g 2. Notes on safety.

Improper use

It is considered improper use when the product

  • is used for any application not stated in these instructions, or
  • is used under operating conditions that deviate from those described in these instructions.
Personnel qualifications

All tasks associated with the product require basic mechanical, pneumatic and electrical knowledge, as well as knowledge of the respective technical terms. In order to ensure operational safety, these tasks may only be carried out by qualified personnel or an instructed person under the direction of qualified personnel.
Qualified personnel are those who can recognize possible dangers and institute the appropriate safety measures, due to their professional training, knowledge, and experience, as well as their understanding of the relevant regulations pertaining to the work to be done. Qualified personnel must observe the rules relevant to the subject area.

General safety instructions
  • Observe the valid local regulations to protect the environment in the country of use and to avoid workplace accidents.
  • Only use AVENTICS products that are in perfect working order.
  • Examine the product for obvious defects, such as cracks in the housing or missing screws, caps, or seals.
  • The warranty will not apply if the product is incorrectly assembled.
  • Do not place any improper mechanical loads on the product under any circumstances.
  • Product warnings and information must be legible, i.e. not covered by paint, etc.

Safety instructions related to the product and technology

  • Lay cables and lines so that they cannot be damaged and no one can trip over them.
  • Do not operate the product in aggressive ambient air (e.g., solvent vapors).
  • No soiling may be allowed to collect on or in the filters, reservoirs or windows. Replace reservoirs if soiling cannot be removed from the drain (drain may become clogged).

Scope of delivery

The scope of delivery includes:

  • 1x oil separator (according to the order)
  • 1 set of operating instructions

About This Product

The oil separator removes oil from the exhaust; the filtering efficiency is 99.99%. The oil separator can also be used as a silencer to reduce exhaust air noise.

Assembly, commissioning and operation

CAUTION”
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or electrical voltage can lead to injuries and damage to the product or system components.

  1. Make sure that the relevant system component is without pressure and voltage before you assemble the product.
  2. Protect the system against being restarted.

CAUTION
Sudden pressure increase during commissioning!
If no SSU filling valve is used, the system will suddenly be under pressure during commissioning! This may result in dangerous erratic cylinder motions.

When commissioning a system, make sure that the cylinders are in their end position. For cylinders not in the end position, make sure they do not present any danger.

CAUTION
System is operating under pressure!
Incorrect installation may damage the maintenance unit/maintenance equip-ment and cause serious injury.

Before commissioning, check that all connections, ports, and maintenance equipment have been correctly installed.

Connecting the oil separator to the tubing system or maintenance unit

The ideal mounting position is at the end of the air circuit.

Assembly without mounting bracketEMERSON-8092708-AVENTICS-MU1-Oil-
Separator-fig1 EMERSON-8092708-AVENTICS-MU1-Oil-Separator-fig2**See g Fig. 1, g Fig. 2.**

Screw the tube into the (a) G1/2 – G1 connection.

Assembly with mounting bracketEMERSON-8092708-AVENTICS-MU1-Oil-Separator-
fig1EMERSON-8092708-AVENTICS-MU1-Oil-
Separator-fig2
See g Fig. 1, g Fig. 2.

  1. Mount the bracket to the oil separator with two hexagon socket screws.
  2. Mount the oil separator to the wall with two screws.
  3. Connect the compressed air to the (a) G1/2 – G1 connection.

Draining oil manuallyEMERSON-8092708-AVENTICS-MU1-Oil-Separator-
fig1
See g Fig. 1.

  1. Turn the condensate drain (b) 1/4 turn counterclockwise and drain the bot-tom section.
  2. Close the condensate drain (b) again.
Mounting the tubing for controlled drainage **

EMERSON-8092708
-AVENTICS-MU1-Oil-Separator-fig1**

See g Fig. 1.
A tubing (c) can be plugged onto the oil drainage fitting at the bottom for controlled oil drainage.

Maintenance and repairs

Cleaning and servicing
  • Close all openings with suitable safety devices so that no cleaning agent can enter into the system.
  • Never use solvents or aggressive detergents. Only clean the product using a slightly damp cloth. Only use water and, if necessary, a mild detergent.
  • Do not use high-pressure cleaners for cleaning.
  • Do not use compressed air for cleaning (blowing off) the maintenance unit or equipment.
Replace filter element:

EMERSON-8092708-AVENTICS-MU1-Oil-Separator-fig3See g Fig. 3.

CAUTION
System is operating under pressure!

Opening the system when it is under pressure can result in personal injury and cause damage to the maintenance unit/device.

Please ensure that the system is not under pressure before you open the reservoir.

Filters become contaminated with use and must be changed annually. This, however, is only a recommendation, since the change intervals depend on the quality of the compressed air and the amount of air throughput.

  1. To change the filter element, turn the bottom section slightly counterclock-wise (a) and pull it off towards the bottom (b).
  2. Remove the filter element (c, d).
  3. Then change the filter element (e, f).
  4. Screw the new filter element into the oil separator (g, h).
  5. Re-mount the bottom section (i, j).

To place your order use the material numbers listed below. If necessary contact one of our addresses (see back cover for contact data).

Wear part Size Material number
Coalescing Filter G1/2 – G3/4 R412028131
Coalescing Filter G1 R412028132

Decommissioning, disassembly, exchange

CAUTION
Danger of injury in case of disassembly or replacement under pressure or voltage!
Disassembling or replacement when under pressure or electrical voltage may lead to injuries and damage to the product or system components.

  1. Make sure that the relevant system part is not under pressure or voltage before disassembling the product or exchanging parts.
  2. Protect the system against being restarted.

Disposal

Dispose of the product and fluid in accordance with the national regulations in your country.

Troubleshooting

Malfunction Possible cause Remedy
No flow Soiled filter Clean or replace filter
Pressure/flow level is not reached or drops off slowly. Soiled filter Clean

or replace filter
Selected filter is too small| Select larger filter

Key Technical Information

Maximum permissible pressure and thread connection are indicated on the products.

General data|
---|---
Mounting orientation| Vertical

The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given information does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.
An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration.
Translation of the original operating instructions. The original operating instructions were created in the German language.
Subject to modifications. © All rights reserved by AVENTICS GmbH, even and especially in cases of proprietary rights applications. This document may not be reproduced or given to third parties without our consent.
The Emerson logo is a trademark and service mark of Emerson Electric Co. AVENTICS is a mark of one of the Emerson Automation Solutions family of business units. All other marks are property of their respective owners.

Emerson Automation Solutions
AVENTICS GmbH
Ulmer Straße 4
30880 Laatzen, GERMANY phone +49 511 2136-0
fax +49 511 2136-269
www.emerson.com/aventics aventics@emerson.com
Further addresses:
www.emerson.com/contactus

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Emerson User Manuals

Related Manuals