Dustcontrol DC AirCube 500 Instructions
- June 4, 2024
- Dustcontrol
Table of Contents
Dustcontrol DC AirCube 500
Safety Considerations
Read all instructions before attempting to operate this machine and save these
instructions.
Warning! When using electric machines, basic safety precautions should always
be followed to reduce the risk of fi re, electric shock and personal injury,
including the following:
-
Work area environment
Don´t expose the machine for rain. Don´t use it in damp or wet locations or in presence of flammable liquids or gases. -
Overload
Never let the machine operate fully throttled. Always follow the regulations pertinent to the material you are working with. Don´t use the machine for purposes that it isn´t intended for. -
Don´t abuse cord
Never pull the machine by cord. Keep cord from heat and sharp edges. Check the electric cable regularly if damaged. The cord should not be wrapped around the handle during operation. -
Important measure
With cleaning and maintenance on the machine, the power cable should be disconnected from the supply. -
Maintain the machine with care
Keep the machine clean and check that the hose (extra accessories) is undamaged and that all gaskets are tight. Follow instructions. Keep handles dry and free from oil and grease. -
Checking for damage
Before further use of the machine, it should be carefully checked that the machine is undamaged. If there are any damaged parts these should be repaired by a Dustcontrol authorized service center. -
Warning
Use only accessories and replaceable parts which are available in the Dustcontrol catalog. When using faulty parts or nonoriginal parts (especially fi lter) the machine could leak out unhealthy dust which can cause personal injuries.
TECHNICAL DATA
- HxWxL 380 x 340 x 495 mm
- Weight 13 kg
- Outlet φ 125 mm
- Hose length (extra accessories) 5-10 m (φ 125)
- Flow, at open outlet 500 m3 /h
- Neg pressure max 400 Pa
- Power consumption 230 V, 210 W, 115 V 50/60 Hz 145 W
Degree of separation,
- EN 1822-1 HEPA 13
*Sound level/:**
- Speed 1 45 dB(A)
- Speed 2 65 dB(A)
Sound level at 1,6 m height and 1 m distance according to DIN EN ISO 3744 in free space and at maximum airflow.
Description
The DC AirCube 500 air cleaner is intended for cleaning the air in a work area and is intended for use as a complement to spot extraction. Air is passed through a combination prefilter and a micro-fi later. The microfilter is a HEPA 13 filter that separates particles to 99.95%. The pre- filter separates the majority of the coarse particles and thereby prolonging the life of the microfilter. When a loss of suction capacity is experienced the prefilter should be changed. If the suction capacity does not increase after the pre- filter change then the Hepa filter should also be changed. Th e fan has two- speed settings which allow for economical running, for example during the night. The DC AirCube 500 can also be used to discharge air from workplaces that must be kept under negative pressure. A 125 mm hose can be attached to the fan outlet where necessary.
NOTE: When using a long tube or covering the outlet, the warning light (fi lter light) can be lit. Check when changing the fi lter that the outlet is free (warning light).
Operation
Connect the machine to a suitable power source according to the specification of the machine. When using an extension cable with the machine, ensure that the connection is water tight and the extension cable is suitably rated. The DC AirCube 500 air cleaner has two-speed settings which allow for economical running, for example during the night.
Service
While performing cleaning or maintenance on the machine, the unit should be off and disconnected from the power supply. When the suction is reduced, due to the filters becoming hen suction is reduced, due to the filters become clogged. The logged. The pre-filter should be changed. Turn the ”soft” e pre- filter should be changed. Turn the ”soft” surface out and the ”hard” surface towards the HEPA- surface out and the ”hard” surface towards the HEPAfi lter. If the suction still is weak, the HEPA filter should be chan- f the suction still is weak, the HEPA filter should be changed too. With heavy dust loads, the life of the filters are ed too. shorter. Use only the original spare part filter 4080. Use suitable breathing protection and do the operation in a closed room. The used filter should be sealed in a plastic bag and disposed of according to approved methods. Check regularly that the electrical cable is not damaged in any way. With the replacement of the cable and contact, use only waterproof replacements. The DC AirCube 500 should be performance tested and checked at least once per year or more frequently if subject to intensive use. Because this machine is used with dangerous sub-stances maintenance is vital, and worn parts should be replaced. Never compromise the function of the DC AirCube 500, use only original spare parts. The fan is maintenance-free.
- Montage:
- Change of prefilter:
- Change of HEPA filter:
- Montage of prefilter:
Accessories
Description Part no
- Hose φ 125 mm 2420
- Hose clamp 4138
- Prefilter 42690
- Microfilter 42692
- Funnel 42753
- Bracket 42724
Other accessories — see Dustcontrol catalogue.
Warranty
Th e warranty period for this machine is two years and covers the manufacturer’s faults. The warranty is valid under the condition that the machine is used under normal conditions on the task for which it was designed and is maintained properly. Normal wear is not covered by this warranty. Service performed by other than Dustcontrol or its authorized agent voids automatically the warranty. No other warranty express or implied is applicable.
TROUBLESHOOTING
Problem Fault Solution
- The machine blows dust. Damaged filter or gasket. Change filter
- The machine runs only on Condenser is faulty. Order parts and replace. one speed.
- Reduction in airfl ow at the exhaust. Filled filter. Change filter.
- The fan does not start. No power. Check power source and connection.
Spare Parts
Part No Description
- 41517 Socket
- 42320 Switch, on/off
- 42665 Exhaust fl ange
- 42666 Protection grill
- 42689 Handle
- 42690 Prefi lter
- 42691 Fan 240 V
- 42692 HEPA fi lter
- 42697 Foot for housing
- 42700 Wing nut M6, plastic, black
- 42713 Fan 115 V
- 42749 Fastener
- 4586 Switch, speed
- 4829 Condenser 400 V 4 μF
- 80461 Micro Switch
- 94156 Original instructions DC AirCube 500
EG-declaration of conformity
We declare that DC AirCube 500 is in conformity with following directives and
standards; 2006/42/EC, 2006/95/EC, 2004/108/EC, EN 60204-1, EN 1822-1. Serial
Number and manufacturing year are indicated in a rating plate on the machine.
Dustcontrol AB
DUST CONTROL WORLDWIDE
UK
Dustcontrol UK Ltd. Old Barn, Home Farm Business Park Church Way, Whittlebury,
Northants NN12 8XS
England – GB
Tel: +44 1327 858001
Fax: +44 1327 858002
sales@dustcontrol.co.uk
www.dustcontrol.co.uk
Get In Touch
- Call: 0845 6880112
- Email: info@adremit.co.uk
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH
References
Read User Manual Online (PDF format)