DELTA THERM KIT-DSR-DRD Roof Gutter Cables Instructions

June 6, 2024
DELTA-THERM

DELTA THERM KIT-DSR-DRD Roof Gutter Cables

Product Information

Specifications

  • Dimensions:
    • Length: 1679.6 mm (66 1/8 in)
    • Width: 611.3 mm (24 1/16 in)
    • Height: 355 mm (14 in)
    • Diameter: 1504.8 mm (59 1/4 in)
  • Material included:
    • AHalf section of the central ring: 2 Qty
    • BBlade: 6 Qty

Product Usage Instructions

Installation Instructions

  1. Remove all sharp objects from the surface to be heated. Clean and degrease the surface.
  2. If installing on a roof with gravel, remove the gravel to allow for close application of the KIT-DSR-DRD to the roof.
  3. Use original Delta-Therm accessories for the heating circuit installation as per Delta-Therm instructions.
  4. Maintain a minimum bend radius of 1 in. (25 mm) with all cables.
  5. NEVER turn on damaged heating circuits.

Installation Steps

  1. Assemble the central ring one side at a time, ensuring proper insertion (a click should be heard).
  2. Insert the self-regulating heating cable into the first of the 6 blades and secure the cable by bending one edge at a time.
  3. Perform a round trip with the cable, penetrating at least 12 in. (305 mm) inside the roof drain.
  4. Bend the edges of the blades to the bottom to stabilize the cable.

CAUTION: Install the roof drain strainer before installing the self- regulating heating cable.

Optional Installation Step

If there is a risk of movement post-installation, secure the KIT-DSR-DRD with a roofing adhesive approved by the membrane manufacturer.

FAQ

Q: What codes must be met during installation?

A: Installation must meet requirements of the Canadian Electrical Code (CSA C22.1 Part 1), National Electrical Code (NFPA 70), and any other applicable local and/or national code.

Q: What should be done if there is a risk of movement post-installation?

A: Secure the KIT-DSR-DRD with a roofing adhesive previously approved by the membrane manufacturer.

INSTRUCTIONS – KIT-DSR-DRD

THE INSTALLATION MUST BE EXECUTED BY A QUALIFIED TECHNICIAN RISK OF ELECTROCUTION

  • Read carefully these instructions before installation, and operation of the heater.
  • Failure to adhere to the instructions could result in fire, electric shock, serious personal injury, and death or property damage.
  • Review frequently for continuing safe operation and instruction of future users, if necessary.

IMPORTANT INSTRUCTIONS

  • Where applicable, installation must meet the requirements of the following codes.
  • Canadian Electrical Code (CSA C22.1 Part 1)
  • National Electrical Code (NFPA 70)
  • Any other applicable local and/or national code
  • Where required by law, this product must be installed by a qualified person.
  • ATTENTION: This product must be installed with a ground fault equipment protector (GFEP).
  • Use only listed conduits, fittings and other components.
  • Use the self-regulating heating cable according to the instructions available on www.delta-therm.com.

WARRANTY

Please refer to the product sheet at www.delta-therm.com.

Global view

Dimensions

Material included

Item Description Qty
A Half section of the central ring 2
B Blade 6

INSTALLATION INSTRUCTIONS

  • Remove all sharp objects from the surface to be heated.
  • Clean and degrease the surface.
  • For installation on a roof with gravel, remove the gravel so that the KIT-DSR-DRD can be applied as close as possible to the roof.
  • Control and accessories: The installation of a heating circuit must be performed using original Delta-Therm accessories, under the Delta-Therm installation instructions.
  • Maintain a minimum bend radius of 1 in. (25 mm) with all cables.
  • NEVER turn on damaged heating circuits.
  1. Assemble the central ring one side at a time (Fig. 1) and make sure that each part is properly inserted into the other half-section (normally a click is heard).
  2. Position the central ring so that it is centred with the roof drain (Fig. 2).
  3. Take each of the 6 blades and insert them into the male part of the central ring (Fig. 3) and make sure that each blade is properly inserted into the central ring (normally a click is heard).
  4. Insert the self-regulating heating cable into the first of 6 blades (Fig. 4) and bend one edge at a time to secure the cable (Fig 6). Do not bend the edge all the way to allow for adjustments with the self-regulating heating cable as needed.
    • Perform a round trip with the self-regulating heating cable (Fig. 4) and penetrate at least 12 in. (305 mm) inside the roof drain.
    • CAUTION: At this step, if you have a roof drain strainer, it must be installed before installing the self-regulating heating cable.
    • When the installation of the self-regulating cable in the 6 blades is complete, be sure to bend the edges of the 6 blades to the bottom to stabilize the self-regulating heating cable.

OPTIONAL DURING INSTALLATION

  • If you feel that there is a risk that the KIT-DSR-DRD may move after installation, you can secure it with a roofing adhesive previously approved by the membrane manufacturer.
  • Delta-Therm can’t be held responsible for any damage that may be caused to a roofing membrane following the installation of KIT-DSR-DRD.

Use the following method after performing steps 1 to 5:

  • Lift the outer end of the blade then apply adhesive directly to the roof. Make sure the adhesive is under the blade (Fig. 7).
  • Apply sufficient pressure with your hands so that the adhesive is in good contact with the roof surface.
  • Repeat this operation on each of the 5 remaining blades (Fig. 8).
  • WARNING: Use only roofing adhesive previously approved by the manufacturer of the roof membrane for your installations.