Lowell Power UPS6LI-600 UPS6LI Series Compact Standby UPS Instruction Manual
- June 3, 2024
- Lowell Power
Table of Contents
- Package Contents
- Product Introduction
- Product Overview
- Installation & Initial Startup
- Indicators & Alarm Conditions
- Important Safety Instructions: (Save These Instructions)
- Troubleshooting
- Specifications
- Obtaining Service
- Limited Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UPS6LI-600 UPS6LI Series Compact Standby UPS
Instruction Manual
©2022 Lowell Manufacturing Company (Rev 4/8/20)
Package Contents
You should be receiving the following items inside the package:
- UPS Unit
- Local Monitoring Software CD
Product Introduction
Thank you for selecting this Uninterruptible Power Supply (UPS). It provides you with protection for connected equipment. Please read this manual before installing the UPS as it provides important information that should be followed during installation and maintenance of the UPS and batteries, allowing you to correctly set up your system for maximum safety and performance. Included is information on customer support and service, if it is required. If you experience a problem with the UPS, please refer to the Troubleshooting section in this manual to correct the problem. If the problem is not corrected, please collect information so that the Technical Support personnel can more effectively assist you.
Product Overview
The UPS6LI Series’ advanced design combines the benefits of lithium-powered
UPS and advanced surge suppression technology. Slim form factor (just 1.25”,
350 model only), wall mounting, and easy access receptacles make it ideal for
mounting behind thin display screens used in hotels, restaurants, hospitals,
campuses, airports and other commercial areas.
The UPS’s compact design is appealing to the digital signage industry, it is
also excellent for providing protection to kiosks, gaming machines, computers,
point-of-sale equipment, and small printers.
Installation & Initial Startup
Note: Before installation, inspect the unit and packaging to make sure
that nothing inside has been damaged.
Connect UPS to Utility and Charging
Before the initial use of the UPS, plug the UPS input cord into a wall outlet
and turn the UPS on by pressing the Power switch on the back of the UPS. For
best results, the batteries in the UPS should be charged for at least 8 hours
before use. The UPS charges its battery while it is connected to AC utility
power and powered on.
Connecting the Loads
Plug the loads to be supported by the UPS into the output receptacles on the
front of the UPS. Simply turn the power switch on the UPS on and the devices
connected to the UPS will be protected by the UPS unit.
Turn UPS ON / OFF
To turn the UPS unit on, press the power button on the UPS and hold for three
seconds. To turn the UPS unit off, press the power button and hold for one
second.
Connecting Local Monitoring Software (optional)
If it is desired to use the Local Monitoring Software, and if your UPS is
equipped with USB communications, connect a USB cable from your computer to
the UPS, and install the software from the CD.
Indicators & Alarm Conditions
Condition | Visual Indicator | Alarm |
---|---|---|
AC mode | LED illuminated | No Audible Alarm |
Battery mode | LED flashes every 10 seconds | An audible Alarm sounds every 10 |
seconds
Low battery mode| LED flashes every 1 second| The audible Alarm sounds every 1
second
Fault| LED is illuminated| The audible Alarm is continuous
Alarm for over-temperature protection| LED flashes every 0.5 seconds| No
Audible Alarm
Important Safety Instructions: (Save These Instructions)
This manual contains important instructions for the UPS6LI Series UPS that
should be followed during the installation and maintenance of the UPS
CAUTION! (UPS having Internal Batteries): Risk of electrical shock –
Hazardous live parts inside this unit are energized from the battery supply
even when the input AC power is disconnected.
CAUTION! (No User serviceable Parts): Risk of electrical shock, do not
remove the cover. No user serviceable parts inside. Refer servicing to
qualified service personnel.
CAUTION! (Non-isolated Battery supply): Risk of electric shock, battery
circuit is not isolated from AC input, the hazardous voltage may exist between
battery terminals and ground. Test before touching.
WARNING! A unit intended for installation in a controlled environment.
CAUTION! Do not dispose of batteries in a fire, the battery may explode.
CAUTION! Do not open or mutilate the battery, released electrolyte is
harmful to the skin and eyes.
CAUTION: A battery can present a risk of electrical shock and high short-
circuit current. Contact with any part of a grounded battery can result in
electrical shock. The following precautions should be observed when working
on batteries:
a) Remove watches, rings, or other metal objects.
b) Use tools with insulated handles.
c) Wear rubber gloves and boots.
d) Do not lay tools or metal parts on top of batteries.
e) Disconnect the charging source and load prior to installing or maintaining
the battery.
f) Remove battery grounds during installation and maintenance to reduce the
likelihood of shock.
Remove the connection from the ground if any part of the battery is determined
to be grounded.
EN 62040-2, C2:
WARNING: This is a category C2 UPS product. In a residential environment,
this product may cause radio interference, in which case the user may be
required to take additional measures.
FCC Notice: Class A
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
WARNING: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
To reduce the risk of electric shock, disconnect the UPS from the main supply
before installing a computer interface signal cable. Reconnect the power cord
only after signaling interconnections have been made.
Servicing of batteries should be performed or supervised by personnel with
knowledge of batteries and the required precautions. Keep unauthorized
personnel away from batteries.
The instructions contained within this safety manual are deemed important and
should be closely followed at all times during installation and follow-up
maintenance of the UPS and batteries.
CAUTION: The unit has a dangerous amount of voltage. If the UPS indicator
is on, the unit’s outlets may have a dangerous amount of voltage even when not
plugged into the wall outlet because the battery may continue to supply power.
Care should be taken to undertake installation indoors, free from
electrically-conductive particles which are under temperature and humidity
control, in order to reduce the risk of electric shock.
It is best to disconnect the device using the power supply cord. Ensure that
the equipment is placed in a position near the outlet where easily accessible.
The socket outlet shall be installed near the equipment and shall be easily
accessible
CAUTION RISK OF EXPLOSION IF THE BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS All servicing on this
equipment must be carried out by qualified service personnel.
Before conducting any maintenance, repair, or shipment, first, ensure that
everything is turned off completely and disconnected.
Troubleshooting
Condition | Visual Indicator | Alarm |
---|---|---|
No LED display on the front UPS panel | Low battery | Charge the UPS at least 8 |
hours
Battery fault| Replace the battery with the same type of battery
The UPS is not turned on| Press the Power Switch on the front of the UPS
The alarm continuously sounds when the AC input is normal| The UPS is
overloaded| Remove some of the load from the output of the UPS
UPS fault| Return the unit for service
The alarm continuously sounds when the AC input is normal| Battery defect|
Replace the battery with the same type of battery
The charging circuit is damaged| Return the unit for service
When power fails, backup time is shorter than expected| The UPS is overloaded|
Remove some of the load from the output of the UPS
Battery voltage is too low| Charge the UPS at least 8 hours
Battery defect| Replace the battery with the same type of battery
The AC input is normal but the blue LED is flashing| The power cord is loose|
Reconnect the input power cord properly
Specifications
MODEL NUMBER| | UPS6LI-350
UPS6LI-600
---|---|---
CAPACITY| Power rating| 350VA (200W) 600VA (360W)
INPUT| Voltage| 120VAC
Frequency| 50/60Hz
OUTPUT| Voltage| 120VAC
Waveform| Sine wave (normal), simulated sine wave (battery mode)
Frequency| 50/60Hz
Surge suppression| 312 joules
Transfer time| 2-6 ms (typical)
BATTERY| Battery type| Lithium Iron Phosphate (LiFePo4)
Battery quantity and size| (8) LiFePO4 18650 cells, 2400mAh| (16) LiFePO4
18650 cells, 4400mAh
PHYSICAL| Dimensions (WxDxH)| 6.9 x 8.5 x 1.25 in (175 x 216 x 32 mm)| 7.3 x
10.8 x 1.6 in (185 x 275 x 40 mm)
Weight| 3.4 lbs (1.5 kg)| 4.9 lbs (2.2 kg)
Line cord| Detachable 5-15P to C13
Receptacles| (3) 5-15R
ENVIRONMENT| Temperature| 32-104°F (0-40°C)
Humidity| 0-90%
Altitude| 11,500 ft above sea level
COMMUNICATIONS INTERFACE| Standard communications| USB Interface
including cable and software| RS-232 Interface
including cable and software
Web/SNMP card option| N/A| External Web/SNMP card providing UPS
monitoring and receptacle On/Off control
Environmental monitoring device| N/A| Measures temperature and humidity
(requires Web/SNMP card option)
APPROVALS| UL-1778, cTUVu, FCC, and RoHS
WARRANTY| 5 years electronics, 5 years battery warranty (USA & Canada)**
AVAILABLE OPTIONS| Web/SNMP adaptor (600VA),
Environmental monitoring sensor (600VA),
power cord with offset/right angle 5-15P plug
INCLUDED IN BOX| ViewPower CD,
5-15P to C13 line cord
Obtaining Service
If the UPS requires service:
- Use the TROUBLESHOOTING section in this manual to eliminate obvious causes.
- Verify there are no circuit breakers tripped.
- Call your dealer for assistance. If you cannot reach the dealer or if they cannot resolve the problem, call Lowell Manufacturing Company at 800-325-9660. Technical support inquiries can also be made by email to sales@lowellmfg.com. Please have the following information available BEFORE calling:
• Your name and address.
• The serial number of the unit.
• Where and when the unit was purchased.
• All of the model information about your UPS.
• Any information on the failure, including LEDs that may or may not be illuminated.
• A description of the protected equipment, including model numbers if possible.
• A representative will ask you for the above information and, if possible, help solve the problem over the phone. In the event that the unit requires factory service, the representative will issue you a Return Material Authorization number (RMA).
If you are returning the UPS for service, please follow these procedures:
- Pack the UPS in its original packaging. If the original packaging is no longer available, ask the Lowell representative about obtaining a replacement set of packaging materials. It is important to pack the UPS properly in order to avoid damage in transit. Never use Styrofoam beads for packing material.
- Include a letter with your name, address, daytime phone number, RMA number, a copy of your original sales receipt, and a brief description of the problem.
- Mark the RMA number on the outside of all packages. Lowell Manufacturing cannot accept any package without the RMA number marked on the outside of the boxes.
- Return the UPS by the insured, prepaid carrier to the address provided by the Lowell representative.
Refer to the Warranty statements in this manual for additional details on what is covered.
Limited Warranty
Lowell Manufacturing Company warrants Lowell UPS equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of five years (USA & Canada) or three years (outside USA & Canada) for UPS6LI Series products from the date of purchase. Lowell Manufacturing Company warrants internal batteries for a period of five years from the date of purchase. For equipment sites within the United States and Canada, this warranty covers repair or replacement, at the sole discretion of Lowell Manufacturing Company. The customer is responsible for the costs of shipping the defective product to Lowell Manufacturing Company. Lowell Manufacturing Company will pay for ground shipment of the repaired or replacement product. For equipment outside the US & Canada, the warranty does not include shipping to and from Lowell Manufacturing Company. This warranty applies only to the original purchaser.
If equipment provided by Lowell Manufacturing Company is found to be Dead-on- Arrival (DOA), Lowell Manufacturing Company will be responsible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer, once the customer has requested and received a Return Material Authorization (RMA) number. DOA equipment is defined as equipment that does not properly function according to user documentation when initially received and connected in conjunction with proper procedures as shown in the user documentation or via support provided by Lowell Manufacturing Company personnel or authorized agents.
This warranty shall be void if (a) the equipment is repaired or modified by
anyone other than Lowell Manufacturing Company or a Lowell Manufacturing
Company approved third party; (b) the equipment is damaged by the customer, is
improperly used or stored, is subjected to an adverse operating environment,
or is operated outside the limits of its electrical specifications; or (c) the
equipment has been used or stored in a manner contrary to the equipment’s
operating manual, intended use or other written instructions. Any technical
advice furnished by Lowell Manufacturing Company or a Lowell Manufacturing
Company authorized representative before or after delivery with regard to the
use or application of Lowell Manufacturing Company equipment is furnished on
the basis that it represents Lowell Manufacturing Company’s best judgment
under the situation and circumstances, but it is used at the recipient’s sole
risk.
EXCEPT AS STATED ABOVE, Lowell Manufacturing Company DISCLAIMS ALL WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE.
EXCEPT AS STATED ABOVE, IN NO EVENT WILL Lowell Manufacturing Company BE
LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF Lowell Manufacturing Company EQUIPMENT, including
but not limited to, any costs, lost profits or revenue, loss of equipment,
loss of use of equipment, loss of software, loss of data, cost of substitutes,
or claims by third parties. Purchaser’s sole and exclusive remedy for breach
of any warranty, expressed or implied, concerning Lowell Manufacturing Company
equipment, and the only obligation of Lowell Manufacturing Company under this
warranty, shall be the repair or replacement of defective equipment,
components, or parts; or, at Lowell Manufacturing Company’s sole discretion,
refund of the purchase price or substitution of an equivalent replacement
product.