INTRODUCTION
Altronix T3MB777K1D is a 24-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre configured with terminal blocks for Mercury* hardware. This unit provides ample power and outputs to support Mercury platform controllers and locking devices. The T3MB777K1D accommodates one (1) Intelligent Dual Reader Controller and eleven (11) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.
*Also compatible with these authentic Mercury partners:
AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt.
Key Features
Accommodates the following Mercury controllers: 1 – LP1502 / LP4502 and 11 – MR52
- Convenient knockout configuration:
- One (1) single knockout 2.415” (2” Conduit)
- One (1) double knockout 1.948” (1.5” Conduit) / 1.701” (1.25” Conduit)
- Sixteen (16) double knockouts 1.362” (1” Conduit) / 1.115” (3/4” Conduit)
- Unit includes:
- Removable backplane with mounting brackets
- Wire management
- Custom Wire Harnesses for power distribution and controller connections
- 16 AWG galvanized steel backplane simplifies board layout and wire management
- AC input and DC output LED indicators
- Supervision
- AC Fail
- Low Battery and Battery Presence
- Low power shutdown
- Built-in charger for sealed lead acid or gel type batteries
- Instantaneous transfer to stand-by batteries
- CE European Conformity
- Enclosure accommodates up to four (4) 12VDC/12AH batteries
- Lifetime Warranty
*Altronix Power Supply/Chargers and Sub-Assemblies only
Specifications
Three (3) Power Supplies (eFlow104NB):
Input
Voltage 120VAC, 60Hz, 13.5A max.
Input Fuse 6.3A/250V
Output
Voltage 24VDC @ 10A
Auxiliary 1A (unswitched)
Protection Overvoltage protection. Filtered and regulated
Battery Backup
Type Sealed lead acid or gel type
Fuse Rating 15A/32V
Failover Upon AC loss, instantaneou
Fire Alarm Disconnect
Supervised Latching or non-latching
EOL 10K Resistor
Supervision
AC Failure Form “C” contacts
Battery Form “C” contacts
Low DC Power Shutdown
Shuts down DC output terminals if battery voltage drops below 70-75% for 24V
units (depending on the power supply) Prevents deep battery discharge
Indicators (LED)
AC Input 120VAC is present
DC Output 24VDC is present
Battery Discharged or not connected
Three (3) Access Power Controllers (ACMS8CB):
Input
Voltage 24VDC from eFlow104NB
Input PTCs 9A
Outputs
Voltage 24VDC
Eight (8) 24VDC independently controlled PTC outputs
a) Fail-Safe and/or Fail-Secure power outputs Form “C” Relays rated 28VAC
or VDC @ 2.5A
b) Auxiliary power outputs (unswitched)
c) Any combination of the above
Output PTCs 2.5A
Indicators (LED)
Red LEDs Outputs are triggered (relays energized)
Green LED FACP disconnect is triggered
Three (3) Power Distribution Modules (PDS8CB):
Input
Voltage 24VDC from eFlow104NB
Input PTCs 9A
Outputs
Voltage 24VDC
Any of the eight (8) power outputs are selectable to follow power Input 1 or
Input 2
Individual outputs may be set to OFF position for servicing
Outputs Ratings
PTCs 2.5A
Indicators (LED)
DC Output Eight (8) individual output LEDs
Green : 12VDC
Red : 24VDC
T3MB777K1D Kit:
Agency Listings
CE European Conformity
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the corresponding Sub-Assembly Installation Guides for further
information.
Physical and Environmental:
-
Dimensions (H x W x D)
-
Enclosure:
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm) -
Shipping:
40.75” x 35.25” x 12” (1035.1mm x 895.4mm x 304.8mm) -
Weight (approx.)
Product 85.6 lb. (42.27 kg)
Shipping 106.4 lb. (48.26 kg) -
Temperature
Operating 0ºC to 49ºC (32ºF to 120ºF)
Storage – 20ºC to 70ºC (– 4ºF to 158ºF)
Relative Humidity 85% +/– 5%
BTU/Hr. (approx.): 433 BTU/Hr.
Accessories
(order separately)
LINQ2 – Network Supervision
Altronix LINQ2 Network Communication Module provides remote supervision,
control and monitoring over LAN/WAN
LINQ2
- Remotely reports accurate power diagnostics
- Controls power and resets devices
- Reports system diagnostics via Email
WM5, WM25, WM100 – Magnetic Cable Tie Mounts
WM5
Altronix WM5, WM25, and WM100 are packs of 5, 25 or 100 magnetic cable tie
mounts respectively.
They accommodate standard zip ties or velcro straps.
These are ideal for wire management in our Trove series.
MM4, MM8, MM12, MM24 – Magnetic Mounting Solution
Mounting Magnet
Altronix mounting magnets accommodate screws and nylon standoffs to allow for mounting various boards/ accessories in any metal enclosure or backplane.
BR1 – Sub-Assembly Mounting Bracket
BR1
Altronix BR1 mounting bracket is compatible with Altronix Maximal and Trove enclosures. It allows to mount one (1) PD4UL(CB), PD8UL(CB), ACM4(CB), MOM5, VR6, PDS8, NetWay5B or LINQ8PD(CB) sub assembly on the enclosure’s inside wall, saving valuable space.
TROVE3BWC / TROVE3SWC – Battery/Wire Trough Enclosure
Typical battery/wiring setup with Trove3 Enclosure (not included)
Altronix Trove3BWC and Trove3SWC are dual-purpose enclosures that can be used
as wiring troughs or battery cabinets when mounted above or below (Trove3BWC)
or on either side (Trove3SWC) of the Trove integrated power and access
solution. The knockouts on the Trove3BWC and Trove3SWC have been strategically
placed to line up with the Trove3 allowing for easy conduit connections
between cabinets.Trove3BWC and Trove3SWC include cam locks and 2 tamper
switches each to ensure access to wiring and batteries is secure.
Dimensions and Drawing
Dimensions (H x W x D approximate)
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)
CUSTOMER SUPPORT
Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA
phone : +1 718.567.8181 |
fax: +1 718.567.9056 |
email: info@altronix.com |
www.altronix.com
T3MB777K1D – includes
(3) eFlow104NB,
(3) ACMS8CB, (3) PDS8CB,
wire harnesses and management
Mercury boards are not included
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>