Honeywell HAC8 Air Conditioner User Manual
- June 1, 2024
- Honeywell
Table of Contents
Honeywell HAC8 Air Conditioner
IMPORTANT SAFETY INSTRUCTIONS
BEFORE YOU BEGIN Read these instructions completely and carefully. Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of ‘Troubleshooting Tips’ First, you may not need to call for service at all. The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32.
This kind of refrigerant is highly flammable. Please ensure that your air
conditioner is installed correctly to avoid the risk of fire To prevent injury
to the user or other people and property damage, the following
instructions must be followed. Incorrect operation due to ignoring
instructions may cause harm or damage.
Warning
To reduce the risk of fire, electrical shock or injury when using your air
conditioner, follow the basic precautions below:
- Plug into a grounded 3-prong outlet.
- Do not remove the ground prong.
- Do not use a plug adapter.
- Do not use an extension cord.
- Unplug the air conditioner before servicing.
- Use two or more people to move and install the air conditioner.
R32 Refrigerant
The refrigerants used for air conditioners are environmentally friendly
hydrocarbons R32. This kind of refrigerant is highly flammable. Please ensure
that your air conditioner is installed correctly to avoid the risk of fire.
Caution
- Please read the manual before installation, use, and maintenance.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- Do not pierce or burn the appliance.
- The appliance shall be stored in a room without continuously operating sources (for example: open flames, an operating ignition gas appliance or an operating electric heater.)
- Please contact the nearest after-sale service centre when maintenance is necessary.
- At the time of maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer and any non-professional is prohibited from maintaining the air conditioner.
- The handling, installation, storage, servicing and disposal must comply with the provisions of gas-related national laws and regulations, and also national wiring regulations.
- It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner. Be aware that refrigerants may not contain an odour.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- Unit operation limits Outdoor side 61~110°F, 80%RH, indoor side 61~90°F, 80%RH.
Electric Shock
- Plug into a grounded 3-prong outlet.
- Do not remove the ground prong.
- Do not use an adapter.
- Do not use an extension cord.
For your safety, this air conditioner must be grounded. This air conditioner is equipped with a 3-prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3-prong outlet and grounded by all local codes and ordinances. If a 3-prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3-prong outlet installed by a qualified electrician.
- This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plugs as required by the US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and an LCDI attachment plug on the line side.
- The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the device has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered shock hazards if exposed.
- The cord shield must not be connected to the ground or any exposed metal.
- The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly.
To test the plug
- Plug the power cord into a wall outlet.
- Press the TEST Button, the circuit should trip and cut all power to the air conditioner.
- Press the RESET button for use.
LCDI Power Cord and Plug
If a test is performed and the indicator light remains ON, the current leakage
has been detected. Do not use the air conditioner or attempt to reset the LCDI
Plug. Contact Customer Service for troubleshooting recommendations.
INSTALLATION INSTRUCTIONS
Prepare the Window
This air conditioner is designed to be installed in a standard double-hung
window with a window width between 23” and 36” (584 mm-914 mm) for 8000
BTU10000 BTU. A window width between 26” and 36” (660mm-914mm) for 12000
BTU14000 BTU. The air conditioner can be installed without the accordion
panels to fit in a narrow window opening. ee, the window dimensions. The Lower
Sash (the lower part of the window that moves up and down) must allow for
14.5” of vertical clearance when open, for 8000 BTU-10000 BTU.
For 16” of vertical clearance, for 12000 BTU-14000 BTU. All supporting parts must be secured to firm wood, masonry, or metal. The electrical outlet must be within reach of the power cord. The air conditioner should be tilted about 3° for better drainage of condensate and rainwater.
NOTE Save the product packaging and installation instructions for future
reference. Store the air conditioner in the product box when not in use for an
extended period.
Top Rail Assembly
The top rail must be assembled before installing the air conditioner in the
window.
Tools Needed: Phillips Head Screw Driver
Attaching the Top Rail to the Air Conditioner
Remove the air conditioner from the box and place on a hard and flat surface.
Caution
When handling the unit, be careful to avoid cuts from the sharp metal edges
and aluminium fins on the front and rear coils Remove the top rail from the
top of the packaging.
Secure the top rail to the unit with the 3/8″ screws
- Remove the top rail from the top of the packaging.
- Secure the top rail to the unit with the 3/8” screws
NOTE: For safety reasons, all 4 screws must be used to attach the top rail
Install the Accordion Panels
NOTE The top rail and sliding panels at each side are offset to provide
the proper pitch to the rear of 5/16″. This is necessary for the proper
condensed water utilization and drainage. If you are not using the side panels
for any reason, this pitch to the rear must be maintained.
- Place the unit on a flat, stable surface. Hold the accordion panel in one hand and gently pull back the centre to free the open end.
- Slide the free end “I” section of the panel directly into the cabinet. Side the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
- Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments.
- Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet.
- Slide the panel in and repeat on the other side.
Storm Window Requirements
A storm window frame will not allow the air conditioner to tilt properly which
in turn, will keep it from draining properly. To adjust for this, attach a
board or piece of wood to the sill. The board or wood piece should have a
depth of at least 1-1/2″. Make sure the board or piece of wood is
approximately 1/2″ higher than the storm window frame. This will allow the air
conditioner to tilt enough for proper drainage.
Placing the Unit Inside a Window
Place the air conditioner on the sill with the bottom mounting rail against
its back edge. Centre the air conditioner and close the window securely behind
the top mounting rail. The air conditioner should be 3° slightly tilted to the
outside area. Use a level, about a 1/3 bubble will be the correct case slant
to the outside. (It is suggested to keep a downward angle to let accumulated
rainwater drain out from the back side of the unit bottom.)
- Once the air conditioner is placed, extend both the left and right accordion panels to the width of the window.
- Place the frame lock between the extended accordion panels and the window sill. Screw a 3/4” (19mm) locking screw through the frame lock and into the window sill. 3/8” screws x 4.
- Drive 1/2” screws into the top of the accordion panel frame and the top rail to securely attach the window air conditioner to the lower sash.
- To secure the lower sash into place, use the sash lock and a 3/4” screw as shown below. For added insulation, cut the supplied insulation foam to the width of the window.
- Insert the foam between the window sashes to prevent air and objects from getting into the room.
Removing the Air Conditioner from the Window
- Turn the air conditioner off and unplug the power cord.
- Remove the sash seal from between windows, and unscrew the sash lock.
- Remove the screws installed through the frame and frame lock.
- Close (slide) the side panels into the frame.
- Keeping a firm grip on the air conditioner, raise the sash and carefully “rock” the air conditioner backward to drain any condensate water in the base of the unit. Be careful not to spill any remaining water while lifting the unit from the window.
- Store parts with the air conditioner in the box.
Refrigerants R32
Read this section before installing the appliance. to avoid serious injuries
when filling the combo table refrigerant.
- Requirements for the total weight of filled refrigerant and the area of a room to be equipped with an air conditioner.
- A leak test must be done after the installation is completed.
- It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant to ensure that the fire risk is reduced to a minimum
- It is necessary to operate the machine under a controlled procedure to ensure that any risk arising from the combustible gas or vapour during the operation is reduced to a minimum.
Site Safety
- Open Flames Prohibited
- Ventilation Necessary
Operation Safety
- Mind Static Electricity
- Must Wear Protective Clothing and anti-static gloves
Installation Safety
- Refrigerant Leak Detector
- Appropriate Installation Location
Please note
The installation site should be in a well-ventilated condition. The site
freeftaan tartaining. miring. dying engRany other 32 sources higher than 548°C
which easily produces open fire When installing an air conditioner, it is
necessary to take appropriate anti-static measures such as wearing anti-static
clothing and/or gloves. the air costa and oles oe icon and outer or tallas
should not sure here by obstacles or close to any heat source or combustible
and/or explosive environment. If the indoor unit suffers a refrigerant leak
during the installation, all the personnel should go out till the refrigerant
leaks completely for 15 minutes. If the product is damaged, it is a must to
carry such damaged product back to the maintenance station and it is
prohibited to weld the refrigerant pipe or conduct.
Please note (contd)
I see sane te Hayse the date where we inlet here a ter of thrice products.
under series on a side ets ke indoor unit and also prevent mechanical damage
from occurring.
USE YOUR AIR CONDITIONER
Operating Sounds may the ra mining non-assed g watering the condenser andy
approve the compressor is not on.
Manual Control Panel
Ul Dicial Display
-
When une umer is not in use. the operation mode and me ser temperature will be displayed. Time will be displayed under the timer setting 0y Mode Button: Press the mode button to cycle through the various modes:
-
Cool and dry. Fan and Auto.
-
Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces humidity. Press the Mode button to activate the cooling function. To optimize this function adjust the temperature by pressing the up and down arrows
-
and the speed by pressing the Fan Speed button.
-
Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press the Mode button to set the DRY mode. An automatic function of alternating cooling cycles and an air fan is activated.
-
Fan Mode: This function only works when the air conditioner is vented. Press the Mode button to set the FAN mode. With pressing the FAN SPEED button, the speed changes in the following sequence: HIGH, MED, LOW in FAN mode.
-
Auto Mode: In AUTO mode the unit automatically chooses the mode of operation (COOL,
-
FAN). In this mode, the temperature is set automatically according to the room temperature
-
(Room temperature is determined by the temperature sensor located in the indoor unit).
Note: You may hear a pinging noise caused by water hitting the condenser. You may hear the thermostat click when the compressor is on and off. The fan may operate even when the compressor is off. -
and Button
Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61°F~88°F or 16°C~31°C. -
Sleep Button
Press the SLEEP button, and all of the display lights will turn off after a while, but the “Sleep” light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically rise or decrease based on the room temperature and the duration of sleep. -
Eco Button
When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user-set temperature. The unit will turn back on when the room temperature rises above the user-set temperature. Before the compressor starts, the fan motor will run for a while, then it will stop for a while and will repeat to provide a much more comfortable feeling and save energy. -
Power Button
Turn the air conditioner on and off. -
Filter Button
When the Filter Check light is off, it is not necessary to press the Filter Check button. When the Filter Check light is on, you can turn off the light by pressing the Filter Check button. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter.
Timer Button
Use these buttons on the control panel and remote to set the Timer. Timer Off:
The timed stop is programmed by pressing the TIMER button. Set the rest time
by pressing the button or until the rest time displayed is to your demand then
press the TIMER button again.
Timer On: When the unit is off, press the TIMER button the first time and
set the temperature by pressing the button. Press the TIMER button the second
time, and set the rest time by pressing the button. Press the TIMER button for
the third time, confirm the setting, and then it will show on the display.
Note: It can be set to automatically turn off or on in 0.5-24 hours. Each
press of the up and down arrow buttons will increase or decrease the timer.
The Timer can be set in 0.5-hour increments below 10 hours and 1-hour
increments for 10 hours or above. The SET light will turn on while setting. To
cancel the set function, press the TIMER button again.
Fan Speed Button
Press the FAN SPEED button to select the fan speed. In COOL MODE you can
choose the following settings: HIGH, MED, LOW, or AUTO. In FAN MODE you can
choose from HIGH, MED, LOW.
Directional Levers
Use the horizontal wheels to control horizontal airflow and the air deflector
to control vertical airflow.
Operating Sounds
POWER
Turn the air conditioner on and off.
COOL
Press the COOL button to COOL mode.
AND
Use these buttons on the control panel and remote to increase or decrease the
Set Temperature or Timer. Temperature range: 61°F~88°F or 16°C~31°C.
SLEEP
Press the SLEEP button, and all of the display lights will turn off after a
while, but the Sleep light is always on. In SLEEP mode, the air conditioner
will automatically adjust the temperature and fan speed to make the room more
comfortable during the night. The set temperature will automatically rise or
decrease based on the room temperature and the duration of sleep.
TIMER
Use these buttons on the control panel and remote to set the Timer. Timer Off:
The timed stop is programmed by pressing the TIMER button. Set the rest time
by pressing the up arrow button or down arrow until the rest time displayed is
to your demand then press the TIMER button again.
Timer On: When the unit is off, press the TIMER button the first time and set
the temperature by pressing the up arrow button or down arrow button. Press
the TIMER button the second time, and set the rest time by pressing the up
arrow button or down arrow button. Press the TIMER button for the third time,
confirm the setting, and then it will show on the display.
Note: It can be set to automatically turn off or on in 0.5-24 hours. Each
press of the buttons will increase or decrease the timer. The Timer can be set
in 0.5-hour increments below 10 hours and 1-hour increments for 10 hours or
above. The SET light will turn on while setting. To cancel the set function,
press the TIMER button again.
AUTO-MODE
In AUTO mode the unit automatically chooses the mode of operation (COOL, or
FAN). In this mode, the temperature will be set automatically according to the
room temperature (tested by the temperature sensor which is incorporated in
the indoor unit.).
FAN SPEED
Press the FAN SPEED button to choose the fan speed options. You can choose
HIGH, MED, LOW or auto speed in COOL mode and choose HIGH, MED, or LOW in FAN
mode.
DISPLAY
To press the DISPLAY button, it can switch off/on all lights or LED displays.
ECO
When the unit is in ECO mode, the light will turn on. In ECO mode, the unit
will turn off once the room is cooled to the user-set temperature. The unit
will turn back on when the room temperature rises above the user-set
temperature. Before the compressor starts, the fan motor will run for a while,
then it will stop for a while and will repeat to provide a much more
comfortable feeling and save energy.
Fan Only
Press the Fan Only button to FAN ONLY mode.
Battery Size
AAA-NOTE: Do not mix old and new batteries or different types of AAA batteries
CARE AND CLEANING
To clean the air filter
- Take off the power plug, then remove the filter by sliding it out from the front right side of the air conditioner.
- Wash the filter using liquid dish soap and warm water. Rinse the filter thoroughly.
- Gently shake the filter to remove excess water.
- Let the filter dry completely before placing it into the air conditioner.
- If you do not wish to wash the filter, you may vacuum the filter to remove the dust and other particles.
Cabinet Cleaning
- Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and the front panel of the air conditioner may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap. Rinse thoroughly with a damp cloth and wipe dry
- Never use harsh cleaners, wax or polish on the cabinet:
- Wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner.
Winter Storage
To store the air conditioner when it is not in use for an extended period.
remove it carefully from the window according to the installation instructions
and cover it with plastic or place it in the original box.
TROUBLESHOOTING
Limited Warranty
Models included are
H101TFS, H16MRB, H16MRS, H33MRB, H33MRS, H31MRS, H31MRB, H11MFW, H11MFB,
H11MFS, H17UFW, H17UFS, H35CFW, H5CFW, H7CFW, H14WCB, H24WCB, H34WCB, H52WCS,
H48BCS, H115BCS, H4MFSS, HDS18SS, HDS24SS, HCTDS1W, HCTDS2W, HAC5, HAC5-B,
HAC6, HAC6-B, HAC8, HAC8-B, HAC10, HAC10-B, HAC12, HAC12-B, HAC14, HAC12-B,
HAC-U8, HAC-U8-B, HAC-U10, HAC-U10-B, HAC-U12-W, HAC-U12-B, H3UFW, H3UFB,
H3UFS, HAC-8I
The products listed above are covered by the terms of this Limited Warranty. For purposes of this Limited Warranty, the term “product” means any appliance manufactured for BHRS Group. BHRS Group warrants that it will, at BHRS Group’s option, replace or repair the Purchaser’s BHRS Group product sold in the U.S. or Canada by an authorized retailer if that product is defective due to faulty workmanship or materials, subject to the limitations described in this Limited Warranty. BHRS Group undertakes no responsibility for the quality of the goods except as otherwise provided in this warranty.
There are no warranties that extend beyond the description on the face hereof. This Limited Warranty is valid only in connection with the original purchase of new products from authorized retailers and extends from the original purchase date of the original product purchased. This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of the original purchase or until the original purchaser of the product sells or transfers the product, whichever first occurs.
An “original purchaser,” for this Limited Warranty, is an individual or entity who purchases the product directly from BHRS Group or an authorized retailer of BHRS Group with the intent to use the product for personal consumer use and commercial or industrial use and not with the intent to resell the product. An “authorized retailer,” for purposes of this Limited Warranty is an individual or entity authorized by BHRS Group to sell the product directly to original purchasers. An individual or entity that purchases the product from whatever source with the intent to resell the product is an unauthorized reseller (“unauthorized reseller”). For this Limited Warranty a “Third Party” would be considered any plumber, maintenance company, or individual hired by the Purchaser.
This Limited Warranty does not apply to used, refurbished, renewed, floor model or “demo” products, or to products sold by unauthorized resellers, including without limitation, unauthorized resellers on third party websites, including, without limitation, Craigslist, eBay, Amazon, etc. Unauthorized resellers are not “original purchasers” of this Limited Warranty. If the purchaser is not the original purchaser of this product, the purchaser takes the product “AS IS,” “with all faults” and without warranty. BHRS Group reserves the right to require a valid serial number located on your product to submit a valid claim under this Limited Warranty. Products where the serial number has been removed or evidence showing the removal or attempted removal of the serial number label will not be eligible to claim under this Limited Warranty.
IF THE PURCHASE OF THIS PRODUCT WAS NOT DIRECTLY FROM BHRS GROUP, PROOF OF PURCHASE WILL BE REQUIRED TO DEMONSTRATE THAT THE PURCHASER IS THE ORIGINAL PURCHASER AND THAT THE PRODUCT WAS PURCHASED FROM AN AUTHORIZED RETAILER, AND ELIGIBLE TO MAKE A VALID CLAIM UNDER THIS LIMITED WARRANTY.
Your purchase date is established from the date of your sales receipt. BHRS Group may require the purchaser to provide proof of the quality and condition of the appliance if the purchaser claims this Limited Warranty. BHRS Group reserves the right to invalidate this Limited Warranty if the appliance is determined, in BHRS Group’s reasonable discretion, to be inadequate or if the appliance is found to be in an unsanitary condition. This warranty does not apply if the product was damaged or failed because of the accident, improper handling or operation, relocation, abuse, misuse, unauthorized repairs made or attempted, or improper installation or maintenance.
Under this Limited Warranty, products are required to be plugged directly into a grounded wall outlet. Plugging a product into an extension cord or surge protector will be considered misuse and will void this Limited Warranty. If damage to the product has occurred during shipping, the damage must be reported to BHRS Group within the first 30 days from the original purchase date to be eligible to claim under the Limited Warranty. Shipping damage reported to BHRS Group outside of the first 30 days from the original purchase date will not be eligible for a valid claim under this Limited Warranty. This warranty does not cover shipping costs for the return of products to BHRS Group for repair or replacement.
To submit a valid claim under this Limited Warranty, troubleshooting the
product with a BHRS Group Customer success Expert is required. If
troubleshooting the product is refused by the Purchaser, BHRS Group reserves
the right to deny the Limited Warranty Claim. In the event, that a part is
necessary to correct the problem with a Product, BHRS Group will provide the
part at no cost to the original purchaser under this Limited Warranty.
Replacing parts or attempting to correct an issue with the Product is required
before submitting a claim for a replacement product under this Limited
Warranty. Instructions for troubleshooting a Product or replacing a part will
be provided by BHRS
Group.
Troubleshooting, repairs, part replacement, installation, and proper maintenance are the responsibility of the Purchaser. Instructions for proper installation and maintenance will be provided in the user manual. Installation, maintenance, or repairs of the Product is the responsibility of the Purchaser. The Purchaser reserves the right to use a Third Party for installation, maintenance, and repair at their own risk. BHRS Group is not responsible for any additional cost incurred for installation, maintenance, or repair of the Product including but not limited to additional material needed for installation or the cost of a Third Party.
Damage or failure of the Product due to improper installation, maintenance, or
repair caused by a Third Party or the Purchaser is not the responsibility of
BHRS Group and will not be covered under this Limited Warranty. Instructions
for proper installation and
maintenance will be provided in the user manual.
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS. IN NO EVENT SHALL BHRS GROUP’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, INCLUDING BUT NOT LIMITED TO ELECTRICAL OR WATER DAMAGE, OR (II) REPLACEMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL BHRS GROUP’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Except as otherwise provided, BHRS Group will not charge the Original Purchaser to repair or replace the purchaser’s Product if it is deemed defective during the length of this Limited Warranty, but any transportation costs associated with repairs or replacements are the Purchaser’s responsibility. No new warranty is provided with a replacement product. The warranty for the replacement product runs from the date of the original purchase of the original product. If repair is necessary, such repair will be at no charge to the Purchaser except for transportation costs associated with such repair or replacement of a product in compliance with the terms of this Limited Warranty.
In the event, that a warranty claim is filed and a warranty replacement is deemed necessary, the purchaser will be required to surrender the original product to BHRS Group at the time of replacement. Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province.
If you want to return or replace the product, please contact the store where it was purchased (remember to bring the purchase invoice). If your product needs repair, please contact us via email or phone. 2023 BHRS Group, LLC. All Rights Reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties concerning this product. This product is manufactured by BHRS
BHRS Group, LLC
585 Prospect St.
Lakewood, NJ 08701
Customer Service Tel: 1-888-604-0295
Customer Service Email:
support@honeywellcoolingappliances.com
Website:
honeywellcoolingappliances.com