PondMAX CAP100 Cap Air Pump Instruction Manual

June 1, 2024
PondMAX

PondMAX-LOGO

PondMAX CAP100 Cap Air Pump

PondMAX-CAP100-Cap-Air-Pump-PRO

WELCOME TO THE WORLD OF PONDMAX™. YOU MADE THE RIGHT CHOICE INVESTING IN THIS QUALITY PRODUCT. THANK YOU AND ENJOY.

BEFORE USING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS OF USE CAREFULLY AND MAKE YOURSELF FULLY FAMILIAR WITH THE UNIT. PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE.

IMPORTANT SAFEGUARDS

Please read the operating instructions and familiarise yourself with the equipment before placing it in service. Correct and safe use of the system requires strict compliance with the safety instructions. For safety reasons, persons less than 16 years of age or infirm persons who are not familiar with these instructions should not use this equipment.

  • Any damage to the equipment or unmerited operation will bring dangers to the surrounding precincts. So if there is any damage of the equipment, it must not be used. The equipment should be placed out of reach of children.
  • For your own safety, disconnect from the power supply before any maintenance of any equipment is attempted on the tank or water body. Always unplug the pump from the power supply when not in use. Never pull the cable to disconnect the plug from the power supply – grasp the plug and pull to disconnect. If required, have a qualified electrician install a weatherproof power supply point near to the pond or water feature (within the cable length of the appliance).
  • Be sure the equipment is installed in a dry environment
  • Do not operate the pump if the appliance or any components of the system, such as the power cable, have been damaged. Check appliance for defects regularly.
  • Always use a properly grounded power supply that is connected to an RCD with a rated residual operating current not exceeding 30mA. As per AS/NZS 3350.2.41:1997
  • To avoid an electric shock, do not attach the plug to the power supply socket with wet hands. The drip loop method should be used to prevent water from traveling down the cable and onto the plug or power supply. If the plug does get wet, do not unplug the cable. Disconnect the circuit breaker that supplies power to the power supply point. Then unplug and examine the plug and power supply point for presence of water. If the powerpoint has become wet, you should consult an electrician before using the power point again.
  • Do not install or store the appliance where it will be exposed to extreme hot or cold temperatures. Do not use in water above 35°C.
  • Do not cut the cable as this will result in voiding your warranty.
  • Care should be taken to arrange the power cable so that it cannot be accidentally tripped over or pulled.
  • Do not attempt to repair the electrical appliance yourself. Return to an authorised service centre or place of purchase if a fault occurs, (regular maintenance is not considered repair and is required by user).

PARTS LIST

PondMAX-CAP100-Cap-Air-Pump-1

CAP100

PondMAX-CAP100-Cap-Air-Pump-2

TECHNICAL SPECIFICATIONS

MODEL CAP20 CAP50 CAP100
VOLTAGE 220-240VAC/50Hz 220-240VAC/50Hz 220-240VAC/50Hz
POWER (W) 8 16 70
MAX PRESSURE (MPa) 0.024 0.03 0.035
MAX OUTPUT (L/MIN) 13 30 100
OUTLET 2 1-6 1-16
CABLE LENGTH (M) 2 2 2
POND VOLUME (M3) 8 18 60

DESIGN HIGHLIGHTS

The PondMAX CAP Airpumps have been manufactured with advanced technology to provide you with the best quality air pump for your pond. Visit our website to view our range of pond filtration, outdoor/underwater lighting, water treatments and general accessories.

  • Special artificial rubber feet to keep a steady air output and pressure
  • Advanced air-compression system, damping system and multi-lever muffler which is extremely low in noise
  • Compact design and long service life

INSTALLATION

For your convenience, we have provided two different front filter cages. One has a built-in flow control, that can be used to adjust the water flow if the flow is too fast for a particular installation. This is used in clean water features, where a “filter-less” system is preferable.

  • Connect the air hose to the air pump outlet, position the air hose in your pond with airstones and switch on.
  • Place the air pump above water level on a flat surface, otherwise connect a non-return valve between air hose a few inches from the air pump to ensure water is not siphoned back into the air pump.

MAINTENANCE

Regularly clean your air hose and air stone (if in use) or change the sponge to ensure maximum output and extend the life of the air pump.

  • CAP20/CAP50 – installation of the filter sponge is as shown
  • CAP100 Simply unscrew the screw at the top of the air pump.

WARRANTY

LIMITED WARRANTY 2+1 YEAR

  • The additional 1 Year Extended Warranty applies when you REGISTER with Aquatec Equipment. See enclosed for details and please retain your proof of purchase and Warranty form.
  • Warranty covers only appliance defects and faulty material and workmanship within a 2 year period.
  • Faults arising due to accidents, misuse, not following manufacturer’s guidelines/ instructions or power surges/spikes/brownouts will not be covered.
  • The warranty will be void if any tampering removal of warranty labels or electrical circuitry is evident.
  • The warranty will be void if the power cord is cut or damaged in any way.
  • The warranty will be void if any visible signs of overheating are present.
  • Loss of livestock, damage to property or personal injury caused by this product will not be covered.
  • Warranty claims caused by installation faults will not be covered.
  • It is the customer’s responsibility to return the faulty appliance for any warranty claim, to Aquatec.
  • For any warranty to be valid, an original proof of purchase must be provided.
  • Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
  • A Warranty claim must be made within 2 years of the date of purchase.

EXTENDED WARRANTY

  • The Extended Warranty period is for an additional 1 Year and commences on the expiration of the Standard Warranty period.
  • Application for Extended Warranty is FREE of any registration cost to the purchaser on completion of the Extended Warranty questionnaire can be found in the box with the item purchased or online at www.aquatecequipment.com.
  • Where Aquatec determines goods are being used in a manner contrary to the instructions, specifications or this Warranty, Aquatec reserves the right to terminate the Extended Warranty for such goods and will provide written notice to the purchaser.

Please consult your retailer for quality original PondMAX replacement parts. Visit www.aquatecequipment.com for your nearest stockists.

HOTLINE 1300 AQUATEC
www.pondmax.com.au

PONDMAX.COM.AU

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PondMAX User Manuals

Related Manuals