Honeywell V4043H1007 3 4 Inch 2 Port Motorised Zone Valve Instruction Manual
- June 9, 2024
- Honeywell
Table of Contents
V4043H1007 3 4 Inch 2 Port Motorized Zone Valve
Instruction Manual
INSTALLATION INSTRUCTIONS
APPLICATION
The V4043H valve has been designed to control the flow of water in iron and
copper pipe systems. Although specifically designed for small bore domestic
central heating systems, the valve can be used in commercial and industrial
applications.
SPECIFICATIONS
Voltage: 230-240V ~ 50 Hz
Power Consumption: 6W
Lead Supplied: V4043H1007/U and V4043H1056/U: 1 meter , 5 core
V4043H1080/U and V4043H1106/U: 1 meter , 6 core
Operating Temperature Range: +5 to +88° C
Maximum Ambient Temperature : +52° C
Pipe Fitting Sizes: 22 mm & 28 mm compression fitting, 3/4” & 1” BSP
Dimensions and KV values: See diagrams
SPARES AVAILABLE
Powerhead | Part No. 40003916-001/U |
---|---|
Motor | Part No. 40002737-003/U |
Ball & O-Ring Kit | Part No. 272742A/U |
INSTALLATION
V4043H incorporates a manual lever, the lever should normally be in ‘AUTO’
position, but can be moved to ‘MAN. OPEN’ position for system drain own and
filling purposes only. Before fitting the valve, read through the plumbing and
wiring instructions.
This product MUST be installed by a competent person. The installation MUST
conform to I.E.T. Regulations and with The Electricity at Work Regulations.
A Class ‘A’ switch (having contact separation of at least 3 mm in all poles)
must be incorporated in the fixed wiring as a means of disconnecting the
supply. The system must be appropriately fused.
PLUMBING
The valve may be plumbed in at any angle, but must not be mounted so that the
valve head is below the horizontal level of the pipework. In the unlikely
event of a leak, a safety hazard could result.
Do not grip the valve head while making and tightening up plumbing
connections. Attach a spanner (32 mm or 1 1/4” AF) onto the valve body at each
port, whilst tightening up the nuts. Tighten compression nuts enough to make a
watertight seal.
TAKE CARE NOT TO OVERTIGHTEN. WIRING
The wiring diagram below shows relevant connections to a junction box (Part
No. 42002116-002). Ensure that each numbered, lettered or coloured wire is
connected to the correct terminal in the junction box. Make sure all
connections are good and all terminal screws are firmly tightened.
NOTE:
Wiring diagram shows connections to a programmer with separate control of
heating and hot water. Note:
- It is recommended that either the 10 way junction box or Sundial wiring centre should be used to ensure first time, fault free wiring.
- If using the V4043H1080/U (1“ BSP) or V4043H1106/U (28 mm), the white wire must be made electrically safe. (“S” Plan only).
CHECKOUT PROCEDURE
To ensure the valve is plumbed and wired correctly, carry out the following
checks after filling the system and switching on the power:
-
a. Check the manual lever is in ‘AUTO’ position.
b. Check programmer has power.
c. Check boiler is switched on and its thermostat set to maximum. -
Confirm correct hot water functions as follows:
a. Turn room thermostat to minimum setting or switch off at programmer.
b. Set cylinder thermostat to maximum and programmer to ‘HOT WATER ON’.
c. Pump should run (S Plan ONLY) and boiler should fire (S and C Plan). Feel pipe approximately 12” from valve port B, it should get hot. -
Confirm correct heating functions as follows:
a. Turn cylinder thermostat to minimum or switch off at programmer.
b. Set room thermostat to maximum and programmer to ‘CENTRAL HEATING ON’.
c. Boiler should fire and pump should run. Feel pipe approximately 12” from pump (C Plan), or valve (S Plan) it should get hot.
COMPLETION
Reset both thermostats to temperature required, normally 60° C for cylinder
thermostat and 20° C for room thermostat. Return programmer to ‘Auto’ or mode
selected by householder. Full installation, wiring and operating instructions
for SUNDIAL products are included in every product pack. For special wiring
diagrams or applications, contact Reside.
ENSURE THAT THE VALVE HEADS HAVE FREE AIR MOVEMENT AROUND THEM.
For “S Plan Plus” or other relevant plans, please scan the QR code to access
the Honeywell Home wiring guide app. Reside Academy supports heating and
plumbing professionals with training from our industry and product experts.
Scan the QR code to access the Reside Academy online or download our app.
Wiring Guide
| Wiring Guide| Reside Academy online
---|---|---
https://apps.apple.com/gb/app/honeywell-home-wiring-guide/id1445695073|
https://play.google.com/store/apps/details?id=com.phonegap.wiringguide|
https://qrco.de/bdjNYg
WEEE Directive 2012/19/EU
The product (and contained batteries) should not be disposed of with other
household waste.
Check for the nearest authorized collection centers or authorized recyclers.
The correct disposal of end-of-life equipment will help prevent potential
negative consequences for the environment and human health.
Manufacturer for European Region:
Pittway Sarl, Z.A. La Piece 6,
1180 Rolle, Switzerland
Country of origin: Hungary
EN0H-2812GE23 R0323 M.S. Rev. 03-23 | Printed in Hungary
Manufacturer for North and South America Region:
Reside Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
© 2023 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell
International, Inc.
www.resideo.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>