QuietCool IT-30003 Adjustable Thermostat User Manual
- June 10, 2024
- QuietCool
Table of Contents
IT-30003
QuietCool Adjustable Thermostat with Fire Safety Shut-off
for Powered Attic Ventilators
PRODUCT FEATURES
- Adjustable thermostat between 50ºF and 120ºF
- Built-in Fire Safety Shut-off to turn fan off if thermostat detects temperature over 182ºF
- Single speed control
- Rated for up-to 10 Amps
- Only for use with Quiet Cool power ventilators
WIRING INSTRUCTIONS
DANGER: Electrical connections on all wiring must be done by a qualified
electrician in accordance with all local codes and standards, including fire-
rated construction. Failure to complete installation properly can result in
fire or even death.
WARNING: Turn off the electrical current to the unit before attempting
any service work.
FOLLOW ALL WIRING DIAGRAMS AND ALL INSTRUCTIONS CAREFULLY. CONNECT TO
115-120V CIRCUIT ONLY.
-
Turn off power to unit at fuse or breaker box.
-
If you are replacing an existing thermostat, remove the cover.
-
Disconnect wiring from the existing thermostat.
-
Remove old thermostat and box from fan at conduit connection in box.
-
Connect one black wire from the thermostat to the black wire of the incoming power supply.
-
Connect the other black wire from the thermostat to the black motor wire.
-
Connect the white wire from the power supply to the white motor wire.
-
Attach the ground wire from the incoming power supply to the ground screw on the thermostat.
CAUTION: Incorrect wiring can cause motor failure and possible fire. -
Replace cover on the thermostat. Check all connections to be sure there are no exposed conductors.
-
Set the temperature control at your desired temperature.
-
Restore power to circuit.
WIRING DIAGRAM