Danner SP-70 Submersible In Line Pumps Instruction Manual

June 1, 2024
DANNER

Danner SP-70 Submersible In Line Pumps

Product Information

Specifications

  • Model: ZG rev C
  • Brand: Danner
  • Type: Submersible In-Line Pump
  • Power Options: Available with or without power cord
  • Includes: Conversion kit for in-line use with a MNPT fitting (for specific models)

Product Usage Instructions

Safety Precautions

  • Always disconnect from the electrical outlet before handling the pump.
  • Do not operate the pump without water.
  • Do not lift the pump by the power cord.
  • Operate the pump in clean water only.
  • Ensure the pump is completely submerged for optimum cooling.
  • Not suitable for use in swimming pools or swimming ponds.

Electrical Safety

  • Use the pump only with a ground fault circuit interrupter (GFCI) or residual current device (RCD) with a rated residual operating current not exceeding mA.
  • Form a Drip Loop with the electrical cord to prevent water from running into the outlet.

Maintenance and Operation

  • Clean or unclog intake screen regularly to maintain performance.
  • If debris has settled, raise the pump slightly to reduce intake contact.
  • Adjust flow control lever for desired water flow output.

Installation Instructions

  • Position Inline Impeller cover with ARROW pointing UP and align the center hole with the Impeller End Cap before pressing into the motor housing.
  • Ensure proper orientation of the Ring Clamp and tighten screws securely.
  • When assembling or disassembling parts, follow the provided instructions carefully to avoid damage.

FAQ

  • Q: What should I do if the pump is not pumping water?
    A: Ensure the pump is fully submerged, check for clogs in the intake screen, and adjust the flow control for optimal performance.

  • Q: How often should I clean the intake screen?
    A: It is recommended to clean or unclog the intake screen regularly to prevent reduced performance.

Danner
Submersible / In-Line* Pumps

CARE AND OPERATING INSTRUCTIONS

Models

  • SP-70
  • SP-93
  • SP-120
  • SP-155
  • SP-200
  • SP-290
  • SP-400
  • SP-530
  • SP-725 /800

Available with 6′ or 15′ power cord *Models 290, 400, 530 & 725 / 800 include conversion kit for in-line use with a 1/2″ MNPT fitting. FITTING NOT INCLUDED

WARNING  PONDS ARE DANGEROUS TO SMALL CHILDREN NEVER LEAVE CHILDREN UNSUPERVISED NEAR A POND

INTRODUCTION

Thank you for purchasing this Danner water pump. This submersible pump provides a continuous stream of water with an adjustable flow control for submersible applications. The pump can be converted for In-Line use using the enclosed parts. Danner pumps are carefully inspected and tested to insure both safety and operating performance. However, failure to follow the instructions and warnings in this manual may result in pump damage and or serious injury. Be sure to read and save this manual for future reference.

Warning

  • Ensure that the electrical cord is looped below the electrical outlet to form a Drip Loop . This will prevent water from running down the cord into the electrical outlet.
  • Risk of electric shock- This pump is supplied with grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to properly grounded grounding-type receptacle.
  • Do not remove the grounding pin from the plug.
  • Do not connect to any voltage other than that shown on the pump.
  • Do not pump flammable liquids.
  • The National Electric Code requires that a Ground Fault Circuit interrupter GFCI be used in the branch circuit supplying fountain pumps and other pond equipment. See your electrical supplies dealer for this device.
  • The pump is to be supplied through a Residual Current Device
  • RCD with a rated residual operating current not exceeding °˘mA.
  • To reduce the risk of electrical shock, use only on portable self-contained fountains.
  • Do not use with water above 95°F (35°C)

Caution This pump has been evaluated for use with water only.

Caution

  • Always disconnect from electrical outlet before handling the pump.
  • Don’t operate without water.
  • Do not lift the pump by the power cord.
  • Operate in clean water only.
  • Operate pump completely submerged for optimum cooling.
  • Not for use in swimming pools or swimming ponds.

This pump is only to be used in an outlet with a ground fault circuit interrupter (GFCI) or residual current device (RCD) with a rated residual operating current not exceeding 30 mA.
NONE: Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop” This will prevent water from running down the cord into the electrical outlet.

PERFORMANCE
A clogged or dirty intake screen will greatly reduce performance.
If the pump is used where debris has settled, raise it slightly to reduce the amount of debris contacting the intake. If slower flow is desired, adjust the flow control lever on the side of the pump or restrict the discharge flow.
Do not run the pump out of the water. Doing so may damage the pump. Always submerge the pump in the water before plugging in the electrical outlet. It is common for air to be in the pump and tube when first plugged in. Continue to unplug the electrical cord and then plug it back in until water begins to flow.

INSTRUCTIONS TO CONVERT PUMP FOR INLINE USE WITH ½/” NPT FITTINGS
*MODELS 290, 400, 530 and 725 / 800 ONLY

  1. Unplug pump. Remove the front cover. Remove Impeller Cover with O-Ring by turning counter clockwise & pulling away from Motor Housing.Danner-SP-70-Submersible-In-Line-Pumps- \(2\) Note If Impeller end cap remains attached to Impeller cover when removing the Impeller Cover, it must be removed and reassembled onto the impeller shaft. Insert impeller into the opening in the motor. Be careful, the powerful magnet may pull the impeller very quickly and possibly injure your finger tips.

  2. Position Inline Impeller cover with ARROW pointing UP, align the center hole with the Impeller End Cap and press into motor housing until completely seated. Turn clockwise until it stops (about 10 degrees).

  3. Ring clamp must be used to lock Inline Impeller Cover in place. Loosen Screw and Nut on Ring Clamp, align slots on Ring Clamp with Fins on Inline Impeller Cover.

Make certain that

  1. Ring Clamp is oriented properly as shown below.
  2. It is properly aligned *SEE NOTE 3 and completely seated over the Impeller cover – then tighten screw.

Danner-SP-70-Submersible-In-Line-Pumps- \(4\)

CARE AND MAINTENANCE

NOTE: Always disconnect from electrical outlet before handling the pump. To clean the pump, remove the front cover, Impeller Cover and the Impeller. Use a soft brush, soft cloth or stream of water to remove any debris. If scale has built up on Impeller or in the impeller chamber, soak in a solution of 1 part white vinegar to 9 parts water for a few hours to soften scale, then use soft brush. For easier reassembly, moisten O-Ring on Impeller Cover with water before reattaching Impeller Cover to Motor Housing.Danner-SP-70-Submersible-
In-Line-Pumps- \(5\)

Remember: Monthly maintenance will add to your pump’s life.

IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING

  • Confirm that the circuit breaker is on and try another outlet to ensure the pump is getting electrical power.
  • Check the pump discharge and tubing for kinks and obstructions.
  • Ensure the inlet is not clogged with debris.
  • Disconnect pump from power source. Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not broken or jammed. Clean or replace.

Remember: Monthly maintenance will add to your pump’s life.

WARRANTY

Danner pumps are warranted against failure due to defects in materials and/or workmanship for 2 years from date of purchase. This warranty covers defects occurring under normal use. The warranty and remedies set forth herein are conditional upon proper installation, use, maintenance, storage, and conformance with the applicable use. It will be based upon Danner Mfg. discretion as to whether the defects are of manufacturing origin. For warranty repair, return only the part that is defective to our factory. Please include a dated proof of purchase and $5.00 for postage and handling. Any damages due to improper installation are not covered by this warranty. This warranty does not apply to appearance or accessory items. This warranty does not include damage due to handling, transportation, unpacking, setup, installation, repair or replacement of parts supplied by any other than Danner Mfg.; improper maintenance, modification or repairs by the purchaser; abuse, misuse, neglect, accident, fire, flood, or other acts of God. Any oral statements about this product made by the seller, the manufacturer, their representatives or any other parties do not constitute warranties and shall not be relied upon by the user and are not part of this contract. Neither the seller nor the manufacturer shall be liable for any injury, loss or damages, direct, incidental, or consequential, including but not limited to incidental or consequential damage for lost profits, lost sales, injury, and inability to use the product and the user agrees that no other remedy is available. Before using, the user shall determine the suitability of the product for their intended use and the user shall assume all risk liability whatsoever in connection therewith. To validate this warranty, keep your proof of purchase (copy of sales receipt). Warranty covers the repair or prorated replacement of the Danner Mfg. products. Danner Mfg. denies all liability for any other loss including but not limited to loss of equipment, income, livestock, or personal injury.
THE FOLLOWING VOIDS WARRANTY: LINE CORD OR PLUG IS ALTERED OR CUT, PRODUCT LABELS ARE DEFACED OR REMOVED. PRODUCT IS IMPROPERLY INSTALLED OR MAINTAINED BY USER OR THEIR AGENT. PRODUCT IS ABUSED, MISUSED, OR DAMAGED BY USER OR THEIR AGENT. PRODUCT IS NOT REMOVED FROM SERVICE AND DRIED DURING FREEZING CONDITIONS.

Distributed by: E G Danner Mfg. Inc. 160 Oval Drive Islandia, NY 11749
Tel: 631-234-5261 or 800-458-5876
Fax: 631-234-7809 or 631-234-4778
Email: [email protected]
Website: www.dannermfg.com