LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump Assembly Instructions
- June 1, 2024
- Lanchez
Table of Contents
LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump
Package Includes
- Submersible Water Pump: The main unit of the LANCHEZ QSB-JH-9003.
- Elbow Connector: An elbow-shaped connector for flexible hose attachment.
- Multi-Step Hose Adapter: A hose adapter with multiple steps to fit various hose sizes.
- Power Cord: A power cord attached to the pump for electrical connection.
Additional Requirements for Setup:
The image also suggests tools and items that might be needed for installation:
- Hose Clamp: For securing the hose to the pump adapter.
- Saw: For cutting the hose to the required length.
- Pliers: For tightening connections.
- Screwdriver: For securing hose clamps or other fittings.
- Discharge Hose: A hose to direct the pumped water away from the area.
- Rope: For lowering and securing the pump in the water.
Tools
Start Guide
Attach the Hose Adapter:
- Step 1: Locate the threaded outlet on the side of the pump.
- Step 2: Take the multi-step hose adapter and screw it onto the threaded outlet as shown in the image. Ensure it is securely fastened.
Connect the Power Cord:
- Step 3: Unwind the power cord and ensure it is free of tangles.
- Step 4: Plug the power cord into a properly grounded 110-120V electrical outlet.
Additional Tips:
- Placement: Position the pump in the desired location, ensuring it is stable and fully submerged in water before powering on.
- Hose Attachment: Attach the appropriate size hose to the multi-step adapter, securing it with a hose clamp if necessary.
- Safety: Ensure that the electrical outlet is safe and dry to prevent any electrical hazards.
Symbols
WARNING – To Reduce The Risk Of Electric Shock, Connect Only To A
Properly Grounded, grounding-type receptacle, Or Equivalent.
CAUTION – To Reduce The Risk Of Electric Shock, Pull Plug Before
Servicing The Pump.
CAUTION – This Pump Has Been Evaluated For Use With Water Only.
WARNING – Risk Of Electric Shock – This Pump Has Not Been Investigated
For Use In Swimming Pool OR Marine Areas.
CAUTION – This Pump Is To Be Used In A Circuit Protected By A Ground
Fault Circuit Interrupter.
Attention danger
Observez
Not connected
Connected
Power up
Stop
Starting properly
Step 1: Lowering the Pump
- Secure the Pump:
- Attach a strong rope to the handle of the pump for safe lowering.
- Do not lift or lower the pump by its power cord.
- Lower the Pump:
- Carefully lower the pump into the water using the attached rope.
- Ensure the pump remains upright during the lowering process.
- The maximum submersion depth is 7 meters.
- Placement:
- Place the pump on a flat and stable surface in the water.
- Ensure the pump is at least 40 cm away from the sides of the container or pit.
- The minimum water depth for operation is 5 mm, but for optimal performance, the suggested running level is 80 mm.
Step 2: Connecting the Hose
- Attach Hose Adapter:
- Attach the provided multi-step hose adapter to the pump’s outlet.
- Ensure the adapter is securely fastened.
- Connect Discharge Hose:
- Attach the discharge hose to the hose adapter.
- Secure the hose with a hose clamp if necessary to prevent leaks.
Step 3: Electrical Connection
-
Check Power Supply:
Ensure the power supply is within the range of 110-120V. -
Plug In:
- Plug the power cord into a properly grounded electrical outlet.
- Ensure the connection is dry and safe from water.
Step 4: Operating the Pump
- Power On:
- Once securely placed and connected, turn on the power supply.
- Monitor the pump to ensure it is operating correctly and water is being discharged efficiently.
Step 5: Safety and Maintenance
-
Monitor Operation:
Regularly check the pump during operation to ensure it remains upright and functions properly. -
Routine Maintenance:
- Periodically clean the pump and impeller to prevent clogging and ensure optimal performance.
- Follow the cleaning instructions provided earlier.
Important Safety Tips:
- Do Not Lift by Cord: Always use a rope for lowering or lifting the pump.
- Stable Placement: Ensure the pump is placed on a stable, level surface.
- Electrical Safety: Keep electrical connections dry and away from water.
- Submersion Depth: Do not exceed the maximum submersion depth of 7 meters.
Cleaning safely
Power Off and Unplug:
- Step 1: Ensure the pump is powered off and unplug it from the electrical outlet (110-120V).
Disassemble the Pump:
- Step 2: Using a screwdriver, remove the screws from the front cover of the pump to detach it. Carefully set the screws aside for reassembly.
Clean the Components:
- Step 3: Wash the detached front cover and the internal components with clean water. Use a brush or sponge to remove any debris, dirt, or buildup from the impeller and other parts.
Reassemble the Pump:
- Step 4: After cleaning, reassemble the pump by aligning the front cover and securing it with the screws. Ensure all parts are properly aligned and tightly fastened.
Additional Tips:
- Regular Maintenance: Regularly clean the pump to ensure optimal performance and longevity.
- Safety First: Always ensure the pump is unplugged before attempting any maintenance or cleaning.
- Check Seals: Inspect the seals and gaskets for any wear or damage during reassembly and replace if necessary.
FAQs
What is the model number of the submersible water pump LANCHEZ QSB-JH-9003?
The model number of the submersible water pump is LANCHEZ QSB-JH-9003.
What is the flow rate of the LANCHEZ QSB-JH-9003 submersible water pump?
The flow rate of the LANCHEZ QSB-JH-9003 submersible water pump is 4450 GPH.
What type of water pump is the LANCHEZ QSB-JH-9003 model?
The LANCHEZ QSB-JH-9003 model is a submersible water pump.
What is the capacity of the LANCHEZ QSB-JH-9003 submersible water pump?
The capacity of the LANCHEZ QSB-JH-9003 submersible water pump is 4450 GPH.
How does the LANCHEZ QSB-JH-9003 submersible water pump operate?
The LANCHEZ QSB-JH-9003 submersible water pump operates by submersion in water.
What is the power source required for the LANCHEZ QSB-JH-9003 submersible water pump?
The power source required for the LANCHEZ QSB-JH-9003 submersible water pump is electricity.
What is the intended use of the LANCHEZ QSB-JH-9003 submersible water pump?
The LANCHEZ QSB-JH-9003 submersible water pump is designed for water pumping applications.
What features distinguish the LANCHEZ QSB-JH-9003 submersible water pump?
The LANCHEZ QSB-JH-9003 submersible water pump features a high flow rate and submersible design.
How does the LANCHEZ QSB-JH-9003 submersible water pump handle debris?
The LANCHEZ QSB-JH-9003 submersible water pump efficiently handles debris while pumping water.
What safety measures should be considered when using the LANCHEZ QSB-JH-9003 submersible water pump?
Safety precautions such as proper grounding and regular maintenance are essential for the LANCHEZ QSB-JH-9003 submersible water pump.
What maintenance practices are recommended for the LANCHEZ QSB-JH-9003 submersible water pump?
Regular cleaning and inspection are recommended for maintaining the optimal performance of the LANCHEZ QSB-JH-9003 submersible water pump.
How does the LANCHEZ QSB-JH-9003 submersible water pump contribute to water circulation?
The LANCHEZ QSB-JH-9003 submersible water pump aids in efficient water circulation for various applications
What is the power rating of the LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump?
The LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump has a power rating of 1 HP (horsepower).
How long is the power cord on the LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump?
The LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump comes with a 25-foot power cord for convenient placement and operation.
What is the maximum discharge height for the LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump?
The maximum discharge height for the LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump is 29 feet.
Video-LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump
Download this Manual:LANCHEZ QSB-JH-9003 4450-GPH Submersible Water Pump Assembly Instructions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>