ProofVision PV12P In Wall Electric Toothbrush Charger with Shaver Socket Instruction Manual
- June 1, 2024
- ProofVision
Table of Contents
ProofVision PV12P Wall Electric Toothbrush Charger with Shaver Socket
INTENDED USE
This product is intended for installation in bathrooms to charge Oral-B and
Braun electric toothbrushes only (excluding the iO and Pulsonic series) and as
a shaver socket outlet for shavers rated 20VA or lower. Any other use may
result in damage to the device or in injury. This appliance can be used by
children aged 8 years and over. Persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge should only use the
device under supervision or having received instructions concerning the
correct use of the appliance in a safe way and the possible hazards involved.
Children should not play with the appliance. Cleaning and user maintenance
should not be carried out by children without
supervision.
SAFETY INSTRUCTIONS
All installation work should be undertaken by a competent person according to
the current edition of the IEE Wiring Regulations (BS 7671) and appropriate
statutory regulations. In the Republic of Ireland, the installation must be by
the ETCI National Rules for Electrical Installations -ET101. IF IN DOUBT,
CONSULT A QUALIFIED ELECTRICIAN Before starting any electrical work, ensure
that the electricity supply is SWITCHED OFF at the mains. For additional
safety, remove the fuse or
switch off the circuit breaker at the fuse box or consumer unit.
IMPORTANT NOTICE –WIRING COLOUR CHANGES
From 1st April 2004, new installations in the UK can be wired using the new EU
Harmonised colours for the supply conductors of twin and earth cable:
- New Colours
- Brown = Live Blue = Neutral
- Green/Yellow = Earth
- Old Colours
- Red = Live Black = Neutral
- The bold colours will cease to be used from 1st April 2006.
Flexible cable colours remain unchanged:
- Brown = Live Blue = Neutral
ROI conductor colours for twin and earth cable and flexible cable
- Brown = Live Blue = Neutral
INSTALLATION AND WIRING INSTRUCTION
- This toothbrush charger unit is suitable for mounting with a 47mm deep 2-gang flush metal box.
- Remove the product and screws supplied from the packaging and remove the front plate before starting installation.
- Feed the incoming supply cable through the appropriate knockout entry in the back box. Ensure a protective cable grommet is fitted when using a flush metal box.
- Remove a suitable length of the outer sheath from the supply cable. Remove 10mm from the live and neutral inner insulation to expose the conductor ends.
- Insert the Neutral conductor into the charger supply unit terminal marked N.
- Insert the Live conductor into the charger supply unit terminal marked L.
- Before connecting the protective earth conductor, ensure that all bare earth conductors are sleeved with a length of Green/ Yellow sleeving (not supplied).
- Insert the sleeved earth conductor into the terminal marked with the Earth symbol. 08. Ensure all wires are secure in their terminals.
- Fit the toothbrush charging unit into the mounting box, taking care not to trap any cables.
- Secure the unit using the fixing screws.
- Ensure that the unit is correctly and securely installed and then fit the snap-fit front plate.
- Refit the supply fuse (if removed) and switch on the main supply.
- Parts that are required to be fixed should be fixed so that they cannot fall into the water.
DISPOSAL OF THE TOOTHBRUSH CHARGER
This symbol on the product or its packaging indicates that this product shall
not be treated as household waste. Instead, it shall be handed over to the
applicable collection point for the recycling of electrical and electronic
equipment. Ensuring this product is disposed of correctly, will help prevent
potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product. The
recycling of materials will help to conserve natural resources.
CUSTOMER CARE CENTRE
technical@proofvision.co.uk
+44 (0) 203 4111 693
ProofVision
UK Unit 1, Avad House, Belvue Road,
Northolt, London, UB5 5HY
EU Notion Technology Ltd, Unit 83
Moat House, 54 Bloomfield Avenue,
Belfast, Northern Ireland, BT5 5AD
Read User Manual Online (PDF format)