Secukey XK5 OSDP Reader User Manual
- June 1, 2024
- Secukey
Table of Contents
Secukey XK5 OSDP Reader
Introduction
It is a waterproof OSDP keypad reader, and also with Wiegand output, can read 125KHz EM card, HID card & 13.56MHz Mifare cards at the same time.
Features:
- Waterproof, conforms to IP66
- OSDP+ Wiegand, AES128 encryption
- Card Type: 125KHz HID, EM & 13.56MHz Milare
- Programmable Wiegand output
- EM card: Wiegand 26-44 bits output (default: 26bits)
- Milare card: Wiegand 26-44, 56, 58bits output (default: 34bits)
- HID card: Wiegand 26-37 bits output
- PIN output: 4 bits, 8 bits or virtual card number
Specifications
Installation
- Drill 2 holes (A, C) on the wall for the screws and one hole (B) for the cable.
- Knock the rubber bungs to the holes (A, C).
- Fix the back cover on the wall with 2 screws.
- Thread the cable through the cable hole (B).
- Attach the unit to the back cover.
Wiring
Color | Function | Notes |
---|---|---|
Red | Power+ | +12V |
Black | GND | Gr ound |
Green | DO | Datao |
White | D1 | Data 1 |
Brown | LED | Green LED Light Control |
Yellow | Buzzer | Buzzer Control |
Blue | A | RS485A |
Gray | B | RS485B |
Connection Diagram
- Connect with OSDP Controller
- Connect with Wiegand Controller
Programming
Note: When enter program mode, need press ” for 5 seconds, then press Master code# (Factory default master code: 123456)
Set Master Code (6 digits)
The Master Code is used to prevent unauthorized access to the system, we
highly recommend immediately updating it and recording the New Master Code
.
-
Set Wiegand Format for EM Cards
-
Set Wiegand Format for HID Cards
-
Set Wiegand Format for MIFARE Cards
-
Set PIN Output Format
-
Set Keypad Backlit
-
Baud Rate Settings (Factory default: 9600)
Note: The baud rate of all readers under the same controller should be set to the same with the controller’s baud rate, otherwise the connection will fail. -
OSDP Address Settings (Factory default: 0)
Note: The addresses of all readers under the same controller should be set to be different, otherwise the two readers will conflict -
Reset to Factory Default (two methods)
- Method 1
- Method 2 (This way is suitable for users forget the master code):
Power off, connect Yellow wire and GND wire, then power on, wait for 5 seconds, there will be a long beep, meas reset to factory default successfully, then disconnect the Yellow wire and GND wire.
- Method 1
Indicator light status
Packing List
Read User Manual Online (PDF format)