Secukey Vcontrol 1 Smart Video Intercom Access User Manual

June 12, 2024
Secukey

Smart Video Intercom Access


User Manual

Introduction

The device is Touch Key Access Controller with WiFi-enabled Intercom. People can install the APP for intercom with their smart phone, and program the access controller by touch key.
It is compatible with both iOS (7.0 above) and Android (4.3 above).

Features:

Intercom

2.4G WiFi connection
Android and iOS available
Full duplex voice intercom
2MP+wide angle camera and night vision
Support TF card with unlimited capacity
Support motion detection, playback, take picture/video, unlock remotely

Access Control

Touch key with one relay, 1000 users (988 common+2 panic+10 visitor)
PIN Length: 4~6 digits
EM card, Mifare card optional
Wiegand 26~44 bits input & output
Can be used as Wiegand reader with LED & buzzer
User data can be transferred
2 devices can be interlocked for 2 doors

Specification:
Video Intercom Network 2.4G WiFi connection
Pixel 2.0Mpx (1080P)
Visual Angle Horizontal 140° wide angle
Night Vision IR-CUT (Colorful at daytime, black and white at night)
Extended Memory TF card with unlimited capacity
Intercom Full duplex voice intercom
Other Functions **Motion detection; Playback; Take picture/video;

Unlock remotely
Access Control| User Capacity
Common User
Visitor User
Panic User|
1000
988
10
2
PIN Length| 4~6 digits
Proximity Card Reader
Radio Technology
Read Range|
EM or Mifare
125KHz/13.56MHz
2~6cm
Wiring Connections| Relay output, exit button, alarm, door contact, Wiegand input/output
Relay
Adjustable Relay Output
Time Lock Output Load|
One (NO, NC, Common)
0~99 Seconds (5 seconds default)
2 Amp Maximum
Wiegand Interface**

PIN Output

| EM card version: Wiegand 26~44 bits input & output (Factory default: Wiegand 26bits)
Mifare card version: Wiegand 26~44 bits input & output (Factory default: Wiegand 34bits)
4 bits, 8 bits (ASCII), 10 digits Virtual Number (Factory default: 4bits)
Electric| Operating Voltage
Idle Current
Active Current| DC 12V
<150mA
<250mA
Environment
Operating Temperature
Operating Humidity| Indoor
-20°C ~ 60°C (-4°F ~ 140°F)
0%RH ~ 86%RH
Physical
Color
DimensionsUnit Weight
Shipping Weight| Zinc-Alloy
Sliver & Black
L145 x W68 x D25(mm) Rectangle
L149 x W70 x D25(mm) Ellipse
450g (Rectangle) / 400g (Ellipse)
550g (Rectangle) / 500g (Ellipse)

Carton Inventory:

Secukey Vcontrol 1 Smart Video Intercom Access - a1

   Diode IN4004 (For relay circuit protection)

   Wall Anchors

   Self Tapping Screws: Φ4*25mm

       Screw Driver

       Master Card

Installation

Remove the back cover from the unit
Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
Knock the supplied rubber bungs to the screw holes(A,C)
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole(B)
Attach the unit to the back cover

Wiring

Wire Color| Function|

Notes

---|---|---
Basic Standalone Wiring
Red| DC +| 12V DC Power Input
Black| GND| Negative Pole of DC Power Input
Blue| Relay NO| Normally Open Relay Output (install diode provided)
Purple| Relay Common| Common Connection for Relay Output
Orange| Relay NC| Normally Closed Relay Output (Install diode provided)
Yellow| OPEN| Request to Exit(REX) Input
Pass-Through Wiring (Wiegand Reader or Controller)
Green| Data 0| Wiegand Output (Pass-through) Data 0
White| Data 1| Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey| Alarm Output| Negative contact for Alarm
Brown| Contact Input| Door/Gate Contact Input (Normally Closed)

Sound and Light Indication

Operation Status

| LED|

Buzzer

---|---|---
Stand by| Red light bright| –
Enter into programming mode| Red light shines| One beep
In the programming mode| Orange light bright| One beep
Operation error| –| Three beeps
Exit from the Programming mode| Red light bright| One beep
Open lock| Green light bright| One beep
Alarm| Red light Shines quickly| Beeps

APP Operation

Here are just a few steps to get you started.

  1. Free APP Downloading
    Search TuyaSmart or Smartlife on Google Play or APP Store

  2. Make sure WiFi works on your mobile phone.

1. Register & Login

(Make sure the registered email is legal and valid, so that you can recover your password once forgotten. Mobile Number is for China Mobile ONLY )

Secukey Vcontrol 1 Smart Video Intercom Access - c3

You will get a verification code in your mail box.

2. Add Device

You can add device by clicking ‘Add Device’ or clicking ‘+’ on the top.
Before Adding the device, please make sure it is in adding mode (Door bell LED flashes slowly).

Secukey Vcontrol 1 Smart Video Intercom Access - c5

Note: To better manage the devices and family members, you will need to create a HOME before you begin to manage this device.

Secukey Vcontrol 1 Smart Video Intercom Access - c6

Intercom voice ON/OFF


Full screen


Take a picture


Intercom ON/OFF


Take a Video


Check the Alarm video record (To use this function, must insert a TF card in the device)


Check the picture or video


Change the theme color


Adjust the volume of device


Motion detection ON/OFF


Unlock the door


3. Operation

Secukey Vcontrol 1 Smart Video Intercom Access - d1

(1) Revise device name and location
(2) Check IP address, ID and time zone of device
(3) Configure one or more devices’ automation
(4) Door bell LED ON/OFF; Flip screen
(5) Adjust device volume
(6)  Motion detection ON/OFF, set the detection sensitivity, set alarm timer
(7) Check the capacity (Total/Used/Remaining) of TF card, and format TF card
(8) Value-added Service
(9) If turn on it, a notification will be sent after device stayed offline in 30 minutes.
(10) Check the FAQ related to device
(11) Share the device by Tuya account, message, email, or chat APPs.(Shared Users can’t unlock the door and set the device, only Family Members can unlock the door.)
(12) Add a shortcut to your home screen.
(13) Restart the device
(14) Remove the device

4. Intercom Calling and Motion Detection

1. The APP is online when intercom calling

Secukey Vcontrol 1 Smart Video Intercom Access - e1

2. The mobile is standby when intercom calling or detecting motion

2.1 Click “You have a visitor” message into the intercom interface
2.2 Click “Motion detected” message into alarm record interface

Secukey Vcontrol 1 Smart Video Intercom Access - e2

Note: There are two ways to check the alarm record

  1. Click the Message button in the intercom interface
  2. Check in the Message Center

Secukey Vcontrol 1 Smart Video Intercom Access - e3

Keypad Operation
Basic Configure:

Function

| Keystroke Steps|

Notes

---|---|---
Set master code| * (Master Code) # 0 (New Code) # (Repeat New Code) #*| Default Master Code is 123456
Standalone/Controller mode|
(Master Code) # 7 7 #| To put the device back to its default factory working mode
Wiegand reader mode| * (Master Code) # 7 8 #*| Wiegand output
Exit|
| Press * to exit programming

Standalone/Controller Mode
Connection Diagram

Common Power Supply

Secukey Vcontrol 1 Smart Video Intercom Access - f1

Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1 N4004 is included in the packing)

Access Control Power Supply

Secukey Vcontrol 1 Smart Video Intercom Access - f2

Users Management:

Function

| Keystroke Steps|

Notes

---|---|---
Add common card user| * (Master Code) # 1 (Read card) / (Input 8/10 digits card number) #*| Using auto ID, the cards can be added continuously
(Master Code) # 1 (User ID) # (Read card) / (Input 8/10 digits card number) #| Select specific ID,
ID number: 0~987
(Master Code) # 1 (User ID) # (Card quantity) # (The first card 8/10 digits number) #| Select specific ID,
ID number: 0~987
Add common PIN user|
(Master Code) # 1 (PIN) #| Using auto ID, the PINs can be added continuously
(Master Code) #1 (User ID) # (PIN) #| Select specific ID, ID number: 0~987
Add panic user|
(Master Code) # 1 (User ID) # (Read card / Input 8/10 digits card number / PIN) #| User ID number is 988,989; PIN length: 4-6 digits except 8888
Add visitor user| (Master Code) # 1 (User ID) # (0~9) # (Read card / Input 8/10 digits card number / PIN) #| (0~9) means times of usage, 0=10 times, after the certain number of times, the card/PIN become invalid automatically ID number: 990~999
Change PIN|
(User ID) # (Old PIN) # (New PIN) # (Repeat new PIN) #| PIN length: 4-6 digits except 8888
Change PIN of Card + PIN access mode| (Read card) (Old PIN) # (New PIN) # (Repeat new PIN) #| There will auto allocate PIN (8888) to cards when adding
Delete user|
(Master Code) # 2 (Read card) / (Input PIN) #| Delete user by card/PIN, the users can be deleted continuously
(Master Code) # 2 (User ID) #| Delete user by ID number
(Master Code) # 2 (Input 8/10 digits card number) #| Delete user by card number
* (Master Code) # 2 (Master Code) #*| Delete all users
Exit|
| Press *to exit programming

Tips for PIN Security (Only valid for 6 digits PIN):

For higher security we allow you to hide your correct PIN with other numbers up to a max of 10 digits.

Example PIN: 123434
You could use (123434) or (123434)
*(“” can be any numbers from 0~9)

Set Access Mode:

Function

| Keystroke Steps|

Notes

---|---|---
Card access| * (Master Code) # 4 0 #*| Entry by card only
PIN access|
(Master Code) # 4 1 #| Entry by PIN only
Card + PIN access| (Master Code) # 4 2 #| Entry by card + PIN
Card or PIN access|
(Master Code) # 4 3 #| Entry by card or PIN (default)
Multi user access| * (Master Code) # 4 3 (2~9) #*| Only after 2~9 valid users, the door can be opened. The interval time of reading can’t exceed 5 seconds
Exit|
| Press* to exit programming

Operation Setting:

Function

| Keystroke Steps|

Notes

---|---|---
Relay time setting| * (Master Code) # 3 (1~99) #*| Time range: 1~99s (default is 5 seconds)
Relay toggle mode|
(Master Code) # 3 0 #| Set the relay to ON/OFF toggle mode
Strike-Out OFF| (Master Code) # 6 0 #| Normal mode (default)
Strike-Out ON|
(Master Code) # 6 1 #| Access will be denied for 10 minutes after 10 failed entry attempts.(Exit button is still workable)
Strike-Out ON (Alarm)| (Master Code) # 6 2 #| It will alarm after 10 failed entry attempts. Enter any valid card / PIN # (user or master) to silence
Disable door open detection|
(Master Code) # 6 3 #| Normal mode (default)
Enable door open detection(Request to connect magnetic contact)| (Master Code) # 6 4 #| Door open too long (1 minutes) or door forced open detection. Enter any valid card / PIN # (user or master) to silence
Alarm time|
(Master Code) # 5 (0~3) #| Time range: 0~3 minutes, default is 1 minute
Disable sound| (Master Code) # 7 0 #| Sound closed
Enable sound|
(Master Code) # 7 1 #| Sound activated (default)
LED always OFF| (Master Code) # 7 2 #| LED is off under standby
LED always ON|
(Master Code) # 7 3 #| LED is on under standby (default)
Keypad backlit always OFF| (Master Code) # 7 4 #| Turn off keypad backlit
Keypad backlit always ON|
(Master Code) # 7 5 #| Turn on keypad backlit
Keypad backlit automatic OFF| (Master Code) # 7 6 #| Automatic off after 20s, it will go ON by pressing any key (this key isn’t taken into consideration) (default)
Set Wiegand input|
(Master Code) # 8 (26~44) #| EM version default is 26 bits Mifare version default is 34 bits
Disable parity bits| (Master Code) # 8 0 #| Disable parity bits
Enable parity bits|
(Master Code) # 8 1 #| Enable parity bits (default)
PIN input bits| * (Master Code) # 8 (4 or 8 or 10) #*| 4=4 bits, 8=8 bits(ASCII), 10=10 digits virtual number
Exit|
| Press * to exit programming

Note: For connecting Wiegand reader with 32, 40 bits input, need disable parity bits

Master Card Usage

Using Master Card to add and delete users

Add Card/ PIN Users|

  1. Input (Master Card)

  2. Input (Card) or (PIN #)
    Repeat step 2 for additional users

  3. Input (Master Card) again

Delete Card/ PIN Users|

  1. Input (Master Card Twice within 5s)

  2. Input (Card) or (PIN #)
    Repeat step 2 for additional users

  3. Input (Master Card) again

Users Operation & Reset to Factory Default

> Open the door: Read valid user card or input valid user PIN #
> Remove Alarm: Enter Master Code # or Master Card or valid user card/PIN
> To reset to factory default & Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.

Remarks:
(1) If no Master Card added, must press the Exit Button for at least 5 seconds before release.(this will make the previous registered Master Card invalid)
(2) Reset to factory default, the user’s information is still retained.

Wiegand Reader Mode
Connection Diagram

Secukey Vcontrol 1 Smart Video Intercom Access - g1

  1. Access Controller
Set Wiegand Output:

Function

| Keystroke Steps|

Notes

---|---|---
Set Wiegand output| * (Master Code) # 8 (26~44) #*| EM version default is 26bits Mifare version default is 34 bits
Disable parity bits|
(Master Code) # 8 0 #| Disable parity bits
Enable parity bits| (Master Code) # 8 1 #| Enable parity bits (default)
PIN output bits|
(Master Code) # 8 (4 or 8 or 10) #**| 4=4 bits, 8=8 bits(ASCII), 10=10 digits virtual number
Exit| ****| Press to exit programming

Note: For connecting Wiegand controller with 32, 40 bits input, need disable parity bits

Advanced Application

User Information Transfer (Valid for Card / PIN Users)

The device supports the User Information Transfer function, and the enrolled user (cards, PINs) can be transferred from one (let’s name it Master Unit) to another (let’s name it Accept Unit).

Connection Diagram:

Secukey Vcontrol 1 Smart Video Intercom Access - g2

  1. The Device
Interlock

Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Devices as “A “and “B” for two doors “1” and “2”

Connection Diagram:

Secukey Vcontrol 1 Smart Video Intercom Access - g3

  1. The Device

If enable interlock, when and only door 2 is closed, the user can read the valid fingerprint/ card or input PIN on Reader A, door 1 will open; then when and only door 1 closed, read valid fingerprint/card or input PIN on Reader B, door 2 will open.

Advanced Setting:

Function

| Keystroke Steps|

Notes

---|---|---
Transfer users| * (Master Code) # 9 8 #*| The master code of two devices must be same. Program on Master Units only.
Disable interlock|
(Master Code) # 9 0 #| Disable interlock (default)
Enable interlock| * (Master Code) # 9 1 #*| The users in two devices must completed same
Exit|
| Press * to exit programming

Simplified Instruction


Function Description| Operation
Enter the Programming Mode| – Master Code – #
then you can do the programming (123456 is the factory default master code)
Change the Master Code|
0 – New Code – # – Repeat the New Code -#
(code: 6 digits)
Add Card User|
1 – Read Card – #
(can add cards continuously)
Add PIN User|
1 – PIN -#
(The PIN is any 4~6 digits except 8888 which is reserved)
Delete User|
2 – Read Card – #
2 – PIN – #
Exit from the Programming Mode|

How to release the door
Card User| Read Card
PIN User| Input PIN #
Mobile User| By Mobile

Secukey Vcontrol 1 Smart Video Intercom Access - h1                 Secukey Vcontrol 1 Smart Video Intercom
Access - h2                 Secukey
Vcontrol 1 Smart Video Intercom Access - h3
140° Wide Angle       Touch Button                Multi-users

Secukey Vcontrol 1 Smart Video Intercom Access - h4                 Secukey Vcontrol 1 Smart Video Intercom
Access - h5                 Secukey
Vcontrol 1 Smart Video Intercom Access - h6
Max 2.0Mpx            Support TF Card            Monitoring

Secukey Vcontrol 1 Smart Video Intercom Access - h7                 Secukey Vcontrol 1 Smart Video Intercom
Access - h8                 Secukey
Vcontrol 1 Smart Video Intercom Access - h9
Video Talking            Night Vision            Remote Unlocking

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Secukey User Manuals

Related Manuals