Secukey HF3 Outdoor FingerKey and Reader User Manual
- June 13, 2024
- Secukey
Table of Contents
Secukey HF3 Outdoor FingerKey and Reader
INTRODUCTION
The device is a single-door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and the low-power circuit makes it a long service life. The device supports 1,000 users (988 common users + 2 panic users + 10 visitor users), and all user data can be transferred from one to another (except fingerprint users). It supports multi-access modes in card access, PIN access, finger print access, card + PIN access, or multi-card PINs/fingerprint access. It has extra features including block enrollment, interlock, Wiegand input & output interface…etc.
Three Versions Optional
The device with Bluetooth function is optional The device with a big user
capacity is optional The device with WiFi function is optional
Features
- Capacitive fingerprint sensor, Touch key
- Metal case, anti-vandal
- Waterproof, conforms to IP66
- One relay, 1,000 users (988 common + 2 panic + 10 visitor)
- PIN length: 4~6 digits
- EM card, EM+ Mifare cards optional
- EM card: Wiegand 26~44 bits input & output
- Catate used as Wigan reader with LED, tet input & output
- Card block enrollment
- Tri-color LED status display
- Integrated alarm & buzzer output
- Pulse mode, Toggle mode
- User data can be transferred (except fingerprint users)
- 2 devices can be interlocked for 2 doors
- Built-in light-dependent resistor (LDR) for anti-tamper
- The backlit keypad can set automatic OFF after 20 seconds
Specifications
Carton Inventor
INSTALLATION
- Remove the back cover from the unit
- Drill 2 holes(A, C) on the wall for the screws and one hole for the cable
- Knock the supplied rubber bungs to the screw holes(A, C)
- Fix the back cover firmly on the wall with 4 flat-head screws
- Thread the cable through the cable hole(B)
- Attach the unit to the back cover
Wiring
Sound and Light Indication
Basic Configure
Enter and Exit Program Mode
Set Master Code
Set the Working Mode
Notes: The device has 3 working modes: Standalone Mode, Controller Mode,
and Wiegand Reader Mode, choose the mode you use.
Standalone Mode / Controller Mode)
STANDALONE MODE
The device can work as a Standalone Access Control for a single door.
- (Factory default mode) -— 77 #
- Connection Diagram
- Common Power Supply
Attention
Install a 1N4004 or equivalent diode is needed when using a common power
supply or the keypad might be damaged. (1N4004 is included in the packing)
Access Control Power Supply
Programming
Programming will vary depending on access configuration. Follow the
instructions according to your access configuration.
Notes
User ID number: Assign a user ID to the access fingerprint/ card/ PIN to track
it.
The Common User ID
- Fingerprint user ID: 0 ~ 98
- PIN/ Card user ID: 100 ~ 987
- Master Fingerprint User ID: 99
- Panic User ID: 988~989
- Visitor User ID: 990~999
- IMPORTANT: User IDs do not have to be proceeded with any leading zeros.
- Recording of User ID is critical. Modifications to the user require the User ID to be available.
Proximity Card
Proximity Card: EM card/ EM+ Mifare cards
- PIN: Can be any 4~6 digits except 8888 which is reserved.
Add Common Users
(Fingerprint user ID: 0 ~ 98, PIN/ Card user ID: 100 – 987; PIN length: 4~6
digits except 8888)
Tips for PIN Security (Only valid for 6 digits PIN)
For higher security we allow you to hide your correct PIN with other numbers
up to a max of 10 digits.
Example PIN: 123434
You could use (123434) or ** (123434) can be any numbers from 0~9
Add Master Fingerprint (By Specified ID: 99)
Add Panic Users (Valid for Card/ PIN Users)
(User ID number is 988, 989; PIN length: 4~6 digits except 8888)
Add Visitor Users (Valid for Card/ PIN Users)
(User ID number is 990~999; PIN length: 4~6 digits except 8888) There are 10
groups of Visitor PIN/card available, the users can be specified up to 10
times of usage, after a certain number of times, i.e. 5 times, the PIN/card
becomes invalid automatically.
Change PIN Users(PIN length: 4~6 digits except 8888)
(Note: WiFi versions don’t support change PIN)
Delete Users
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation
Set Access Mode
For Multi-user access mode, the interval time of reading can not exceed 5
seconds, or else, the device will exit to standby automatically.
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is
OFF). It can be set to deny access for 10 minutes after engaging or disengage
only after entering a valid fingerprint/ card/ PIN or Master code/
fingerprint/ card.
Set Door Open Detection
Door Open Too Long (DOTL) Detection When used with an optional magnetic
contact or built-in magnetic contact of the lock, if the door is opened
normally, but not closed after 1 minute, the inside buzzer will beep
automatically to remind people to close the door. The beep can be stopped by
closing the door, master users or valid users, or else, it will continue to
beep at the same time as the alarm time set. Door Forced Open Detection When
used with an optional magnetic contact or built-in magnetic contact of the
lock, if the door is opened by force, the inside buzzer and external alarm (if
there is one) will both operate, they can be stopped by the master users or
valid users, or else, it will continue to sound the same time with the alarm
time set.
The function of Set Alarm Time also applies to anti-tamper alarm
Set Audible and Visual Response
Master Fingerprint/ Card Usage
Users Operation & Reset to Factory Default
- Open the door: Read a valid user fingerprint or user card or input a valid user PIN #
- Remove Alarm: Enter Master Code # or Master Fingerprint/ Card or valid-user fingerprint/card / PIN
- To reset to factory default and add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light will turn yellow, then read any 125KHz EM card/ 13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully.
- If the card is reading, it is the Master Card.
Remarks
- lf no Master Card is added, must press the Exit Button for at least 5 seconds before release. (this will make the previously registered Master Card invalid)
- Reset to factory default, the user’s information is still retained.
CONTROLLER MODE
The device can work as a Controller, connected to the external Wiegand reader.
(Factory default mode) — 7 7 #
Connection Diagram
Attention: Install a 1N4004 or equivalent diode is needed when using a common power supply, or the reader might be damaged. (1N4004 is included in the packing)]
Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand output format of
the external Roador
Note: For connecting Wiegand readers with 32, 40, and 56-bit output, need to disable parity bits.
Programming
- Basic Programming is the same as Standalone Mode
- There are some exceptions for your attention:
- The device is connected to an External Card Reader
- If EM/Mifare card reader: users can be added/deleted on either the
- If HID card reader: users can only be added/deleted on extemal reader.
- The device is connected to the Fingerprint Reader
For example
Step 2: Add the same Fingerprint(A) on the device:
The device is connected to a Keypad Reader
The keypad reader can be 4 Bits, 8 Bits (ASCIl), or 10 Bits output format.
Choose the below operation according to the PIN output format of your reader.
Remarks
4 means 4 bits, 6 means o bits, 10 means 10 digits virtual number.
Delete PIN Users: the same way as add users.
WIEGAND READER MODE
Condeve – work as Standard regarding Reader, connected to the third party
Connection Diagram
Notes:
- When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Brown & Yellow wires will be redefined as below:
- Brown wire: Green LED light control
- Yellow wire: Buzzer control
- If you need to connect Brown/Yellow wires:
- When the input voltage for LED is low, the LED will turn Green; and when the input voltage for Buzzer is low, it will sound.
Set Wiegand Output Formats
Please set the Wiegand output formats of Reader according to the Wiegandinnut
formats of the Controller
Note
For connecting the Wiegand controller with 32, 40, and 56-bit input, need
to disable parity bits.
ADVANCED APPLICATION
Collection Card Mode After this mode is turned on, all cards can open the
lock. At the same time, the card is added to the device.
User Information Transfer (Valid for Card / PIN Users)
The fears, rid an e transcreation one for Sinarion matter moved
Connection Diagram
Remarks
- The Master units and Accept units must be the same series of devices.
- The Master Code of the Master Unit and the Accept Unit must be set to the same.
- Pine ace tits roper it in aster gentle, will be covered after transferring.
- For the full 900 users enrolled, the transfer takes about 30 seconds.
Set Transferring on Master Unit
Interlock
Those and many Fison, and /or Deser o higher level security is required.
Connection Diagram
Remarks: The Door Contact must be installed and connected as per the diagram. and name the two Devices as “A “and “B” for two doors “‘”
Step 1
Enrol the users on Device A, then transfer the users’ information to Device B
by the “User Information Transfer” function.
Step 2
Set both of the two devices (A and B) to Interlock function If enable
interlock, when and only door 2 is closed, the user can read the valid
Outdoor FingerKey & Reader
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>