HI-LINK IB-LS-1W Power Module Instructions

June 1, 2024
Hi-Link

IB_LS-1W Power Module Model Table

SELECTION OF POWER SUPPLY MODULE

Rated voltage input, isolated stabilized single output 1W

  • 4 Pin, SIP international standard pins
  • Isolation voltage ≤ 1500VDC
  • Low staic current and high conversion efficiency
  • Low ripple coefficient and low noise
  • Continuous short-circuit protection
  • Working temperature -40°C  -+85°C Model
Model Nominal Value(±10%) Output Voltage/Current
IB0503LS-1WR3 5V(4.75V-5.25V) 3.3V/303mA
IB0505LS-1WR3 5V/200mA
IB0509LS-1WR3 9V/111mA
IB0512LS-1WR3 12V/84mA
IB0515LS-1WR3 15V/67mA
IB0524LS-1WR3 24V/42mA
IB1203LS-1WR3 5V(11.4V-12.6V) 3.3V/303mA
IB1205LS-1WR3 5V/200mA
IB1209LS-1WR3 9V/111mA
IB1212LS-1WR3 12V/84mA
IB1215LS-1WR3 15V/67mA
IB1224LS-1WR3 24V/42mA
IB2403LS-1WR3 5V(22.8V-25.2V) 3.3V/303mA
IB2405LS-1WR3 5V/200mA
IB2409LS-1WR3 9V/111mA
IB2412LS-1WR3 12V/84mA
IB2415LS-1WR3 15V/67mA
IB2424LS-1WR3 24V/42mA
  • The picture only for reference, please refer to the actual product
Product Feature
  1. characteristic: Constant voltage input, isolated non stabilized voltage single output,1W
  2. Isolation voltage ≤1500VDC
  3. output short-circuit protection
  4. The voltage of the input power supply is relatively stable. (Voltage variation range±10%Vin)
  5. operating temperature range -40°C~+85°C
  6. The stability of output voltage is not required.
  7. Small SIP package, plastic housing
  8. International standard pin out method
  9. Adopts high quality environmental protection, waterproof and heat conducting adhesive for filling and sealing, moisture-proof and vibration proof, meeting the waterproof and dustproof IP65 standard
  10. High reliability and long life design, continuous working time MTBF≥3.5 million hours (3500000Hrs)
Environment Condition
Project name Qualification Unit Notes
Working environment temperature -40—+85
Storage temperature -40—+125 ℃
Relative humidity 5—95 %
Heat dissipation mode  natural cooling
Atmospheric pressure 80—106 Kpa Kpa
Ripple & Noise  30/80(max) Mvp-p 
Input Characteristics
Item Working conditions Min. Typ. Max Unit
Reflection ripple current Impulse voltage 15 m’A
3.3VDC Input Series -0.7 5 VDC
5VDC Input Series -0.7 9
9VDC Input Series -0.7 15
12VDC Input Series -0.7 18
15VDC Input Series  -0.7 21
24VDC Input Series -0.7 30
Input filter type Hot plugged Capacitive filtering Non-support
Output Characteristics

Project name| Working and testing condition| Min.| Typ.| Max.| Unit
---|---|---|---|---|---
Output load| load percentage| 10| —| 100| %
Output Voltage Accuracy| 100% load| —| —| ±3| %
Linear adjustment rate| Input voltage 3.3V output| —| —| ±3| %
variation ±1% others output | —| —| ±2| %
Load adjustment rate| 10%~100% load| —| —| ±3| %
3.3VDC Output others output | —| —| ±2| %
Ripple & Noise| Pure resistive load, 20HMz bandwidth, peak-to-peak| —| 50| —| mVp-p
Temperature Drift Coefficient| Full load | —| —| ±0.03| %/℃
Output short circuit protection| 1s| | | |

Note:
(1) The test method of ripple and noise twisted pair test method.
(2) The series module does not have the input anti-reverse function, it is strictly forbidden to reverse the in put positive and negative connection, otherwise it will cause irreversible damage to the module

Typical Application Reference Circuit( Recommended Parameters)
1. Conventinal applications

To further reduce the input and output ripple, a capacitor filter network can be connected to the input and output terminals, and the application circuit is shown in Figure 1.
However, care should be taken to select the appropriate filtering capacitor. If the capacitor is too large, it is likely to cause start-up problems. For each output, under the condition of ensuring safe and reliable operation, the recommended capacitive load value is detailed in Table 1. recommended capacitive load value details (Table 1).

Single circuit

HI-LINK IB-LS-1W Power Module 1

Positive and negative dual circuit

HI-LINK IB-LS-1W Power Module 2
Figure 1

Vin( Vdc) Cin(uF) Vo(Vdc) Cout(uF)
3.3/5 10uF/16V 3.3/5 10uF/16V
9/12 4.7uF/25V 9/12 4.7 uF/25V
15/24 2.2 uF/50V 15/24 1uF/50V

Table(1)

2. EMI typical application circuit

Single circuit

HI-LINK IB-LS-1W Power Module 3
Recommended EMI reference circuit value details (Table 2)

Vin (Vdc) 3.3/5/9/12/15/24
Cin Refer to Table 1
Cout Refer to Table 1
Lin 4.7uH
Lout 4.7uH
3. Output load requirements

To ensure that the module works efficiently and reliably, the minimum output load must not be less than 10% of the rated load when in use. If the power you need is really small, please connect a resistor in parallel between the positive and negative terminals of the output (the sum of the actual power used by the resistor is greater than or equal to 10% of the rated power and the rated power of the selected resistor must be more than 5 times the actual power used, otherwise the temperature of the resistor will be higher).

Note:

1. The above is only a list of typical products. If you need products beyond the list, please contact our sales.
2. The maximum capacitive load indicates the maximum capacitive load that + VO or – vo can be connected to, If the value is exceeded, the product will not start normally..

Product dimensions and pin definition, suggested printing layout

1) Appearance dimensions (unit: mm, tolerance: xx±0.25)

HI-LINK IB-LS-1W Power Module 4

  1. Front view
  2. Bottom View
  3. Side view
  4. Printed side

2) Pin definition

Pin 1 2 3 4 5 6
Single circuit +Vin -Vin No Pin -Vout No Pin +Vout

3) Suggested print version

*Note: Grid distance: 2.542.54mm**

*Note: If the definition of each pin of the power supply module does not match with the selection manual, the label on the physical label shall prevail.