CISCO 9300-EX Ethernet Switched Port Analyzer
Specifications
- Product Name: Cisco NX-OS devices
- Functionality: Ethernet switched port analyzer (SPAN)
- Supported Platforms: All switches except Cisco Nexus 9300-EX/-FX/-FX2 platform switches and Cisco Nexus 9500 series platform switches with -EX/-FX line cards
Product Usage Instructions
Configuring SPAN
This section describes how to configure the Ethernet-switched port analyzer
(SPAN) on Cisco NX-OS devices to analyze traffic between ports.
About SPAN
SPAN analyzes all traffic between source ports by directing the traffic to a
destination port with an external analyzer attached. You can define the
sources and destinations to monitor in a SPAN session on the local device.
Configuring SPAN
This chapter describes how to configure an Ethernet switched port analyzer
(SPAN) to analyze traffic between ports on Cisco NX-OS devices.
This chapter contains the following sections
- About SPAN, on page 1
- Prerequisites for SPAN, on page 4
- Guidelines and Limitations for SPAN, on page 4
- Default Settings for SPAN, on page 12
- Configuring SPAN, on page 12
- Verifying the SPAN Configuration, on page 21
- Configuration Examples for SPAN, on page 21
- Additional References, on page 25
About SPAN
SPAN analyzes all traffic between source ports by directing the SPAN session
traffic to a destination port with an external analyzer attached to it.
You can define the sources and destinations to monitor in a SPAN session on
the local device.
SPAN Sources
The interfaces from which traffic can be monitored are called SPAN sources.
Sources designate the traffic to monitor and whether to copy ingress (Rx),
egress (Tx), or both directions of traffic. SPAN sources include the
following:
- Ethernet ports (but not subinterfaces)
The inband interface to the control plane CPU
When you specify the supervisor inband interface as a SPAN source, the device monitors all packets that are sent by the Supervisor CPU.
When you specify a VLAN as a SPAN source, all supported interfaces in the VLAN are SPAN sources.
- VLANs can be SPAN sources only in the ingress direction.
This applies to all switches except Cisco Nexus 9300-EX/-FX/-FX2 platform switches, and Cisco Nexus 9500 series platform switches with -EX/-FX line cards.
Note
- Satellite ports and host interface port channels on the Cisco Nexus 2000 Series Fabric Extender (FEX)
- These interfaces are supported in Layer 2 access mode and Layer 2 trunk mode. They are not supported in Layer 3 mode, and Layer 3 subinterfaces are not supported.
- Cisco Nexus 9300 and 9500 platform switches support FEX ports as SPAN sources in the ingress direction for all traffic and in the egress direction only for known Layer 2 unicast traffic flows through the switch and FEX. Routed traffic might not be seen on FEX HIF egress SPAN.
Note A single SPAN session can include mixed sources in any combination of the above.
Characteristics of Source Ports
SPAN source ports have the following characteristics:
- A port configured as a source port cannot also be configured as a destination port.
- If you use the supervisor inband interface as a SPAN source, all packets generated by the supervisor hardware (egress) are monitored.
Rx is from the perspective of the ASIC (traffic egresses from the supervisor
over the inband and is received by the ASIC/SPAN).
Note
SPAN Destinations
SPAN destinations refer to the interfaces that monitor source ports.
Destination ports receive the copied traffic from SPAN sources. SPAN
destinations include the following:
- Ethernet ports in either access or trunk mode
- Port channels in either access or trunk mode
- Uplink ports on Cisco Nexus 9300 Series switches
Note FEX ports are not supported as SPAN destination ports.
Characteristics of Destination Ports
SPAN destination ports have the following characteristics:
- A port configured as a destination port cannot also be configured as a source port.
- The same destination interface cannot be used for multiple SPAN sessions. However, an interface can act as a destination for a SPAN and an ERSPAN session.
- Destination ports do not participate in any spanning tree instance. SPAN output includes bridge protocol data unit (BPDU) Spanning Tree Protocol hello packets.
SPAN Sessions
You can create SPAN sessions to designate sources and destinations to monitor.
See the Cisco Nexus 9000 Series NX-OS Verified Scalability Guide for
information on the number of supported SPAN sessions.
This figure shows a SPAN configuration. Packets on three Ethernet ports are
copied to destination port Ethernet 2/5. Only traffic in the direction
specified is copied.
Figure 1: SPAN Configuration
Localized SPAN Sessions
A SPAN session is localized when all of the source interfaces are on the same
line card. A session destination interface can be on any line card.
Note A SPAN session with a VLAN source is not localized.
SPAN Truncation
Beginning with Cisco NX-OS Release 7.0(3)I7(1), you can configure the
truncation of source packets for each SPAN session based on the size of the
MTU. Truncation helps to decrease SPAN bandwidth by reducing the size of
monitored packets. Any SPAN packet that is larger than the configured MTU size
is truncated to the given size. For example, if you configure the MTU as 300
bytes, the packets with greater than 300 bytes are truncated to 300 bytes.
SPAN truncation is disabled by default. To use truncation, you must enable it
for each SPAN session.
ACL TCAM Regions
You can change the size of the ACL ternary content addressable memory (TCAM)
regions in the hardware.
For information on the TCAM regions used by SPAN sessions, see the Configuring
IP ACLs chapter of the Cisco Nexus 9000 Series NX-OS Security Configuration
Guide.
High Availability
The SPAN feature supports stateless and stateful restarts. After a reboot or
supervisor switchover, the running] configuration is applied. For more
information on high availability, see the Cisco Nexus 9000 Series NX-OS High
Availability and Redundancy Guide.
Prerequisites for SPAN
SPAN has the following prerequisites:
- You must first configure the ports on each device to support the desired SPAN configuration. For more information, see the Cisco Nexus 9000 Series NX-OS Interfaces Configuration Guide.
Guidelines and Limitations for SPAN
Note For scale information, see the release-specific Cisco Nexus 9000 Series
NX-OS Verified Scalability Guide.
SPAN has the following configuration guidelines and limitations:
- A maximum of 48 source interfaces are supported per SPAN session (Rx and Tx, Rx, or Tx). • Traffic that is denied by an ACL may still reach the SPAN destination port because SPAN replication is performed on the ingress side prior to the ACL enforcement (ACL dropping traffic).
- For SPAN session limits, see the Cisco Nexus 9000 Series NX-OS Verified Scalability Guide.
- All SPAN replication is performed in the hardware. The supervisor CPU is not involved.
- You can configure a SPAN session on the local device only.
- Configuring two SPAN or ERSPAN sessions on the same source interface with only one filter is not supported. If the same source is used in multiple SPAN or ERSPAN sessions, either all the sessions must have different filters or no sessions should have filters.
- The following guidelines apply to SPAN copies of access port dot1q headers:
- When traffic ingresses from a trunk port and egresses to an access port, an egress SPAN copy of an access port on a switch interface always has a dot1q header.
- When traffic ingresses from an access port and egresses to a trunk port, an ingress SPAN copy of an access port on a switch interface does not have a dot1q header.
- When traffic ingresses from an access port and egresses to an access port, an ingress/egress SPAN copy of an access port on a switch interface does not have a dot1q header.
- Packets with FCS errors are not mirrored in a SPAN session.
- You can configure only one destination port in a SPAN session.
- You cannot configure a port as both a source and destination port.
- Enabling UniDirectional Link Detection (UDLD) on the SPAN source and destination ports simultaneously is not supported. If UDLD frames are expected to be captured on the source port of such SPAN session, disable UDLD on the destination port of the SPAN session.
- SPAN is not supported for management ports.
- Statistics are not support for the filter access group.
- SPAN is supported in Layer 3 mode; however, SPAN is not supported on Layer 3 subinterfaces or Layer 3 port-channel subinterfaces.
- When a SPAN session contains source ports that are monitored in the transmit or transmit and receive direction, packets that these ports receive can be replicated to the SPAN destination port although the packets are not actually transmitted on the source ports. Some examples of this behavior on source ports are as follows:
- Traffic that results from flooding
- Broadcast and multicast traffic
- SPAN sessions cannot capture packets with broadcast or multicast MAC addresses that reach the supervisor, such as ARP requests and Open Shortest Path First (OSPF) protocol hello packets, if the source of the session is the supervisor Ethernet in-band interface. To capture these packets, you must use the physical interface as the source in the SPAN sessions.
- VLAN SPAN monitors only the traffic that enters Layer 2 ports in the VLAN.
- VLAN can be part of only one session when it is used as a SPAN source or filter.
- VLAN ACL redirects to SPAN destination ports are not supported.
- When using a VLAN ACL to filter a SPAN, only action forward is supported; action drop and action redirect are not supported.
- The combination of VLAN source session and port source session is not supported. If the traffic stream matches the VLAN source session and port source session, two copies are needed at two destination ports. Due to the hardware limitation, only the VLAN source SPAN and the specific destination port receive the SPAN packets. This limitation applies only to the following Cisco devices:
Table 1: Cisco Nexus 9000 Series Switches
Cisco Nexus 93120TX | Cisco Nexus 93128TX | Cisco Nexus 9332PQ |
---|---|---|
Cisco Nexus 9372PX | Cisco Nexus 9372PX-E | Cisco Nexus 9372TX |
--- | --- | --- |
Cisco Nexus 9396PX | Cisco Nexus 9372TX-E | Cisco Nexus 9396TX |
Table 2: Cisco Nexus 9000 Series Line Cards, Fabric Modules, and GEM Modules
N9K-X9408PC-CFP2 | N9K-X9536PQ | N9K-C9508-FM |
---|---|---|
N9K-X9432PQ | N9K-X9564PX | N9K-C9504-FM |
N9K-X9464PX | N9K-X9564TX | N9K-C9516-FM |
N9K-X9464TX | N9K-X9636PQ | N9K-M4PC-CFP2 |
The number of SPAN sessions per line card reduces to two if the same interface is configured as a bidirectional source in more than one session. This guideline does not apply for Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards.
-
When you filter a monitor session, make sure that the access-group specified must be a VACL, or VLAN access-map and not a regular ACL for filtering purpose. This guidelines is not applicable for Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards.
-
Supervisor-generated stream of bytes module header (SOBMH) packets have all the information to go out on an interface and can bypass all forwarding lookups in the hardware, including SPAN and ERSPAN. CPU-generated frames for Layer 3 interfaces and the Bridge Protocol Data Unit (BPDU) class of packets are sent using SOBMH. This guideline does not apply for Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards. The Cisco Nexus 9636C-R and 9636Q-R both support inband SPAN and local SPAN.
-
Cisco NX-OS does not span Link Layer Discovery Protocol (LLDP) or Link Aggregation Control Protocol (LACP) packets when the source interface is not a host interface port channel.
-
SPAN copies for multicast packets are made before rewrite. Therefore, the TTL, VLAN ID, any remarking due to an egress policy, and so on, are not captured in the SPAN copy.
-
If SPAN is mirroring the traffic which ingresses on an interface in an ASIC instance and egresses on a Layer 3 interface (SPAN Source) on a different ASIC instance, then a Tx mirrored packet has a VLAN ID of 4095 on Cisco Nexus 9300 platform switches (except -EX, -FX, or -FX2) and Cisco Nexus 9500 platform modular switches.
-
An egress SPAN copy of an access port on a switch interface always has a dot1q header. This guideline does not apply for Cisco Nexus 9508 platform switches with 9636C-R and 9636Q-R line cards.
-
The flows for post-routed unknown unicast flooded packets are in the SPAN session, even if the SPAN session is configured not to monitor the ports on which this flow is forwarded. This limitation applies to Network Forwarding Engine (NFE) and NFE2-enabled EOR switches and SPAN sessions that have Tx port sources.
-
VLAN sources are spanned only in the Rx direction. This limitation does not apply to the following switch platforms which support VLAN spanning in both directions:
-
Cisco Nexus 9300-EX platform switches
-
Cisco Nexus 9300-FX platform switches
-
Cisco Nexus 9300-FX2 platform switches
-
Cisco Nexus 9504, 9508, and 9516 switches with the 97160YC-EX line card.
Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards. -
If a VLAN source is configured as both directions in one session and the physical interface source is configured in two other sessions, Rx SPAN is not supported for the physical interface source session.
This limitation applies to the Cisco Nexus 97160YC-EX line card.
- Session filtering functionality (VLAN or ACL filters) is supported only for Rx sources. This guideline does not apply for Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards.
- The FEX NIF interfaces or port-channels cannot be used as a SPAN source or SPAN destination. If the FEX NIF interfaces or port-channels are specified as a SPAN source or SPAN destination, the software displays an unsupported error.
- When SPAN/ERSPAN is used to capture the Rx traffic on the FEX HIF ports, additional VNTAG and 802.1Q tags are present in the captured traffic.
- VLAN and ACL filters are not supported for FEX ports.
- If the sources used in bidirectional SPAN sessions are from the same FEX, the hardware resources are limited to two SPAN sessions.
- Truncation is supported only for local and ERSPAN source sessions. It is not supported for ERSPAN destination sessions.
- Configuring MTU on a SPAN session truncates all packets egressing on the SPAN destination (for that session) to the MTU value specified.
- The cyclic redundancy check (CRC) is recalculated for the truncated packet.
- The bytes specified are retained starting from the header of the packets. The rest are truncated if the] packet is longer than the MTU.
SPAN Limitations for the Cisco Nexus 3000 Platform Switches
The following guidelines and limitations apply only the Nexus 3000 Series switches running Cisco Nexus 9000 code:
- The Cisco Nexus 3232C and 3264Q switches do not support SPAN on CPU as destination.
- SPAN Limitations for the Cisco Nexus 9200 Platform Switches
- Note For scale information, see the release-specific Cisco Nexus 9000 Series NX-OS Verified Scalability Guide.
The following guidelines and limitations apply only the Cisco Nexus 9200 platform switches:
- For Cisco Nexus 9200 platform switches, Rx SPAN is not supported for multicast without a forwarding interface on the same slice as the SPAN destination port.
- Tx SPAN for multicast, unknown multicast, and broadcast traffic are not supported on the Cisco Nexus 9200 platform switches.
- Tx SPAN of CPU-generated packets is not supported on Cisco Nexus 9200 platform switches.
- UDF-based SPAN is supported on the Cisco Nexus 9200 platform switches.
- The Cisco Nexus 9200 platform switches do not support Multiple ACL filters on the same source.
- VLAN Tx SPAN is supported on the Cisco Nexus 9200 platform switches.
- When multiple egress ports on the same slice are congested by egressing SPAN traffic, those egress ports will not get the line rate on the Cisco Nexus 9200 platform switches.
- Using the ACL filter to span subinterface traffic on the parent interface is not supported on the Cisco Nexus 9200 platform switches.
- On the Cisco Nexus 9200 platform switches, the CPU SPAN source can be added only for the Rx direction (SPAN packets coming from the CPU).
- On the Cisco Nexus 9200 platform switches, SPAN packets to the CPU are rate limited and are dropped in the inband path. You can change the rate limit using the hardware rate-limiter span command. You can analyze SPAN copies on the supervisor using the ethanalyzer local interface inband mirror detail command.
SPAN Limitations for the Cisco Nexus 9300 Platform Switches
Note For scale information, see the release-specific Cisco Nexus 9000 Series
NX-OS Verified Scalability Guide.
The following guidelines and limitations apply only the Cisco Nexus 9300 platform switches:
-
The following filtering limitations apply to egress (Tx) SPAN on all Cisco Nexus 9300-EX/FX/FX2 platform switches:
-
ACL filtering is not supported (applies to both unicast and Broadcast, Unknown Unicast and Multicast (BUM) traffic)
-
VLAN filtering is supported, but only for unicast traffic
VLAN filtering is not supported for BUM traffic -
On Cisco Nexus 9300-EX/FX platform switches, SPAN and sFlow cannot both be enabled simultaneously.
If one is active, the other cannot be enabled. However, on Cisco Nexus
9300-EX/FX/FX2 platform switches, both NetFlow and SPAN can be enabled
simultaneously, providing a viable alternative to using sFlow and SPAN.
Note Cisco Nexus 9300-FX2 switches support sFlow and SPAN co-existence.
- VLAN Tx SPAN is supported on Cisco Nexus 9300-EX and FX platform switches
- Cisco Nexus 9300 platform switches support multiple ACL filters on the same source.
- A single forwarding engine instance supports four SPAN sessions. For Cisco Nexus 9300 platform switches, if the first three sessions have bidirectional sources, the fourth session has hardware resources only for Rx sources.
- Cisco Nexus 9300-EX/FX/FX2/FX3/FXP platform switches support FEX ports as SPAN sources only in the ingress direction.
- Cisco Nexus 9300 platform switches (excluding Cisco Nexus 9300-EX/FX/FX2/FX3/FXP switches) support FEX ports as SPAN sources in the ingress direction for all traffic and in the egress direction only for known Layer 2 unicast traffic flows through the switch and FEX. Routed traffic might not be seen on FEX HIF egress SPAN.
- Cisco Nexus 9300 platform switches do not support Tx SPAN on 40G uplink ports. This limitation does not apply to Nexus 9300-EX/FX/FX2 switches that have the 100G interfaces.
Note
-
Tx SPAN of CPU-generated packets is not supported on Cisco Nexus 9200, 9300-EX/FX/FXP/FX2/FX3/GX/GX2, 9300C, C9516-FM-E2, and C9508-FM-E2 switches.
-
Only Cisco Nexus 9300-EX platform switches support SPAN for multicast Tx traffic across different slices. The slices must be on the same leaf spine engine (LSE).
-
For Tx interface SPAN with Layer 2 switch port and port-channel sources on Cisco Nexus 9300-EX/FX/FX2 platform switches, only one copy is made per receiver unit regardless of how many Layer 2 members are receiving the stream in the same VLAN. For example, if e1/1-8 are all Tx direction SPAN sources and all are joined to the same group, the SPAN destination port sees one pre-rewrite copy of the stream, not eight copies. In addition, if for any reason one or more of those ports drops the packets on egress (for example, due to congestion), the packets may still reach the SPAN destination port. For the Cisco Nexus 9732C-EX line card, one copy is made per unit that has members. For port-channel sources, the Layer 2 member that will SPAN is the first port-channel member.
-
SPAN Tx broadcast and SPAN Tx multicast are supported for Layer 2 port and port-channel sources
across slices on Cisco Nexus 9300-EX/FX/FX2 platform switches, and the Cisco Nexus 9732C-EX line card, but only when IGMP snooping is disabled. (Otherwise, the slice limitation still applies.) These features are not supported for Layer 3 port sources, FEX ports (with unicast or multicast traffic), and VLAN sources. -
A SPAN copy of Cisco Nexus 9300 platform switch 40G uplink interfaces will miss the dot1q information when spanned in the Rx direction. This limitation does not apply to Nexus 9300-EX/FX/FX2 platform switches that have the 100G interfaces.
Note
- UDF-based SPAN is supported on the Cisco Nexus 9300-EX/FX/FX2 platform switches.
- UDF-SPAN acl-filtering only supports source interface rx. This limitation applies to the following
switches:
- Cisco Nexus 9332PQ
- Cisco Nexus 9372PX
- Cisco Nexus 9372PX-E
- Cisco Nexus 9372TX
- Cisco Nexus 9372TX-E
- Cisco Nexus 93120TX
- The Cisco Nexus 9300-EX/FX/FX2 platform switches do not support Multiple ACL filters on the same source.
- When multiple egress ports on the same slice are congested by egressing SPAN traffic, those egress ports will not get the line rate on the Cisco Nexus 9300-EX/FX/FX2 platform switches.
- Using the ACL filter to span subinterface traffic on the parent interface is not supported on the Cisco Nexus 9300-EX/FX/FX2 platform switches.
- On the Cisco Nexus 9300-EX/FX/FX2 platform switches, the CPU SPAN source can be added only for the Rx direction (SPAN packets coming from the CPU).
- On the Cisco Nexus 9300-EX/FX/FX2 platform switches, SPAN packets to the CPU are rate limited and are dropped in the inband path. You can change the rate limit using the hardware rate-limiter span command. You can analyze SPAN copies on the supervisor using the ethanalyzer local interface inband mirror detail command.
SPAN Limitations for the Cisco Nexus 9500 Platform Switches
Note For scale information, see the release-specific Cisco Nexus 9000 Series
NX-OS Verified Scalability Guide.
The following guidelines and limitations apply only the Cisco Nexus 9500
platform switches:
- The following filtering limitations apply to egress (Tx) SPAN on 9500 platform switches with EX or FX line cards:
- ACL filtering is not supported (applies to both unicast and Broadcast, Unknown Unicast and Multicast
(BUM) traffic)
-
VLAN filtering is supported, but only for unicast traffic
-
VLAN filtering is not supported for BUM traffic
-
FEX and SPAN port-channel destinations are not supported on the Cisco Nexus 9500 platform switches with EX or FX line cards.
-
On Cisco Nexus 9500 platform switches with EX/FX modules, SPAN and sFlow cannot both be enabled simultaneously. If one is active, the other cannot be enabled. However, on the Cisco Nexus 9500 platform switches with EX or FX line cards, NetFlow and SPAN can both be enabled simultaneously, providing a viable alternative to using sFlow and SPAN.
-
Cisco Nexus 9500 platform switches support VLAN Tx SPAN with the following line cards:
-
Cisco Nexus 97160YC-EX
-
Cisco Nexus 9732C-EX
-
Cisco Nexus 9732C-FX
-
Cisco Nexus 9736C-EX
-
Cisco Nexus 9736C-FX
-
Cisco Nexus 9736Q-FX
-
Cisco Nexus 9788TC-FX
-
Cisco Nexus 9500 platform switches support multiple ACL filters on the same source.
-
Tx SPAN of CPU-generated packets is not supported on Cisco Nexus 9500 platform switches with EX-based line cards.
-
TCAM carving is not required for SPAN/ERSPAN on the following line cards:
-
Cisco Nexus 9636C-R
-
Cisco Nexus 9636Q-R
-
Cisco Nexus 9636C-RX
-
Cisco Nexus 96136YC-R
Note All other switches supporting SPAN/ERSPAN must use TCAM carving.
- On the Cisco Nexus 9500 platform switches, depending on the SPAN source’s forwarding engine instance mappings, a single forwarding engine instance may support four SPAN sessions. This guideline does not apply for Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards.
- Multiple ACL filters are not supported on the same source.
- Cisco Nexus 9500 platform switches support FEX ports as SPAN sources in the ingress direction for all traffic and in the egress direction only for known Layer 2 unicast traffic flows through the switch and FEX. Routed traffic might not be seen on FEX HIF egress SPAN.
- SPAN does not support destinations on Cisco Nexus 9408PC-CFP2 line card ports.
- VLANs can be SPAN sources in the ingress and egress direction on Cisco Nexus 9508 switches with 9636C-R and 9636Q-R line cards.
UDF-SPAN acl-filtering only supports source interface rx. This limitation applies to the following line cards:
- Cisco Nexus 9564PX
- Cisco Nexus 9464TX2
- Cisco Nexus 9464TX
- Cisco Nexus 9464TX2
- Cisco Nexus 9564TX
- Cisco Nexus 9464PX
- Cisco Nexus 9536PQ
- Cisco Nexus 9636PQ
- Cisco Nexus 9432PQ
Default Settings for SPAN
The following table lists the default settings for SPAN parameters.
Parameters | Default |
---|---|
SPAN sessions | Created in the shut state |
Configuring SPAN
Note Cisco NX-OS commands for this feature may differ from those in Cisco IOS.
Configuring a SPAN Session
You can configure a SPAN session on the local device only. By default, SPAN
sessions are created in the shut state.
Note
For bidirectional traditional sessions, you can configure the sessions without
specifying the direction of the traffic.
Before you begin
You must configure the destination ports in access or trunk mode. For more
information, see the Cisco Nexus 9000 Series NX-OS Interfaces Configuration
Guide
Procedure
| Command or Action| Purpose
---|---|---
Step 1| configure terminal
Example:
switch# configure terminal switch(config)#
| Enters global configuration mode.
| Command or Action| Purpose
---|---|---
Step 2| interface ethernet slot / port
Example:
switch(config)# interface ethernet 2/5 switch(config-if)#
| Enters interface configuration mode on the selected slot and port.
Step 3| switchport
Example:
switch(config-if)# switchport
| Configures switchport parameters for the selected slot and port or range of
ports.
Step 4| switchport monitor
Example:
switch(config-if)# switchport monitor
| Configures the switchport interface as a SPAN destination.
Step 5| (Optional) Repeat Steps 2 through 4 to configure monitoring on
additional SPAN destinations.| —
Step 6| no monitor session session-number
Example:
switch(config)# no monitor session 3
| Clears the configuration of the specified SPAN session. The new session
configuration is added to the existing session configuration.
Step 7| monitor session session-number [ rx | tx ] [ shut
]
Example:
switch(config)# monitor session 3 rx switch(config-monitor)#
Example:
switch(config)# monitor session 3 tx switch(config-monitor)#
Example:
switch(config)# monitor session 3 shut switch(config-monitor)#
| Enters the monitor configuration mode. The new session configuration is
added to the existing session configuration. By default, the session is
created in the shut state, and the session is a local SPAN session. The
optional keyword shut specifies a shut state for the selected session.
Step 8| description description
Example:
switch(config-monitor)# description my_span_session_3
| Configures a description for the session. By default, no description is
defined. The description can be up to 32 alphanumeric characters.
Step 9| source { interface type [ rx | tx | both ]
| [ vlan
{ number | range }[ rx ]} | [ vsan { number |
range }[ rx ]}
Example:
switch(config-monitor)# source interface ethernet 2/1-3, ethernet 3/1 rx
Example:
| Configures sources and the traffic direction in which to copy packets. You can enter a range of Ethernet ports, a port channel, an inband interface, a range of VLANs, or a satellite port or host interface port channel on the Cisco Nexus 2000 Series Fabric Extender (FEX).
You can configure one or more sources, as either a series of comma-separated entries or a range of numbers.
| Command or Action| Purpose
---|---|---
| switch(config-monitor)# source interface port-channel 2
Example:
switch(config-monitor)# source interface sup-eth
0 rx
Example:
switch(config-monitor)# source vlan 3, 6-8 rx
Example:
switch(config-monitor)# source interface ethernet 101/1/1-3
| You can specify the traffic direction to copy
as ingress (rx), egress (tx), or both.
Note Source VLANs are supported only in the ingress direction. Source FEX ports are supported in the ingress direction for all traffic and in the egress direction only for known Layer 2 unicast traffic.
This note does not aply to Cisco Nexus 9300-EX/-FX/-FX2 series platform switches, and Cisco Nexus 9500 series platform switches with -EX/-FX line cards.
Supervisor as a source is only supported in the Rx direction.
For a unidirectional session, the direction of the source must match the direction specified in the session.
Step 10| (Optional) Repeat Step 9 to configure all SPAN sources.|
Step 11| filter vlan { number | range }
Example:
switch(config-monitor)# filter vlan 3-5, 7
| Configures which VLANs to select from the configured sources. You can configure one or more VLANs, as either a series of
comma-separated entries or a range of numbers
Note A FEX port that is configured as a SPAN source does not support VLAN filters.
Step 12| (Optional) Repeat Step 11 to configure all source VLANs to
filter.|
Step 13| (Optional) filter access-group acl-filter
Example:
switch(config-monitor)# filter access-group ACL1
| Associates an ACL with the SPAN session.
Step 14| Required: destination interface type slot / port
Example:
switch(config-monitor)# destination interface ethernet 2/5
Example:
| Configures a destination for copied source packets.
Note The SPAN destination port must be either an access port or a trunk port.
| Command or Action| Purpose
---|---|---
| switch(config-monitor)# destination interface sup-eth 0| Note You must
enable monitor mode
on the destination port.
| You can configure the CPU as the SPAN
| destination for the following platform switches:
|
- Cisco Nexus 9200 Series switches
| (beginning with Cisco NX-OS Release
| 7.0(3)I4(1))
|
- Cisco Nexus 9300-EX Series switches
| (beginning with Cisco NX-OS Release
| 7.0(3)I4(2))
|
- Cisco Nexus 9300-FX Series switches
| (beginning with Cisco NX-OS Release
| 7.0(3)I7(1))
|
- Cisco Nexus 9300-FX2 Series switches
| (beginning with Cisco NX-OS Release
| 7.0(3)I7(3))
|
- Cisco Nexus 9500-EX Series switches
| with -EX/-FX line cards
| To do so, enter sup-eth 0 for the interface type.
Step 15| Required: no shut
Example:
switch(config-monitor)# no shut
| Enables the SPAN session. By default, the session is created in the shut
state.
Step 16| (Optional) show monitor session { all |
session-number | range session-range } [ brief ]
Example:
switch(config-monitor)# show monitor session 3
| Displays the SPAN configuration.
Step 17| (Optional) copy running-config startup-config
Example:
switch(config)# copy running-config startup-config
| Copies the running configuration to the startup configuration.
Configuring UDF-Based SPAN
You can configure the device to match on user-defined fields (UDFs) of the outer or inner packet fields (header or payload) and to send the matching packets to the SPAN destination. Doing so can help you to analyze and isolate packet drops in the network.
Before you begin
Make sure that the appropriate TCAM region (racl, ifacl, or vacl) has been
configured using the hardware access-list tcam region command to provide
enough free space to enable UDF-based SPAN. For more information, see the
“Configuring ACL TCAM Region Sizes” section in the Cisco Nexus 9000 Series NX-
OS Security Configuration Guide.
Procedure
| Command or Action| Purpose
---|---|---
Step 1| configure terminal
Example:
switch# configure terminal switch(config)#
| Enters global configuration mode.
Step 2| udf udf-name offset-base offset length
Example:
switch(config)# udf udf-x packet-start 12 1
switch(config)# udf udf-y header outer l3 20 2
| Defines the UDF as follows:
- udf-name —Specifies the name of the UDF. You can enter up to 16 alphanumeric characters for the name.
- offset-base —Specifies the UDF offset base as follows, where header is the packet header to consider for the offset:
packet-start | header { outer | inner { l3
| l4 }}.
- offset —Specifies the number of bytes offset from the offset base. To match the first byte from the offset base (Layer 3/Layer 4 header), configure the offset as 0.
- length —Specifies the number of bytes from the offset. Only 1 or 2 bytes are supported. To match additional bytes, you must define multiple UDFs.
You can define multiple UDFs, but Cisco recommends defining only required UDFs.
Step 3| hardware access-list tcam region { racl | ifacl
| vacl } qualify qualifier-name
Example:
switch(config)# hardware access-list tcam region
racl qualify ing-l3-span-filter
| Attaches the UDFs to one of the following TCAM regions:
- racl—Applies to Layer 3 ports.
- ifacl—Applies to Layer 2 ports
- vacl—Applies to source VLANs.
You can attach up to 8 UDFs to a TCAM region.
| Command or Action| Purpose
---|---|---
| | Note When the UDF qualifier is added,
the TCAM region goes from single wide to double wide. Make sure enough free space is available; otherwise, this command will be rejected. If necessary, you can reduce the TCAM space from unused regions and then re-enter this command. For more information,see the “Configuring ACL TCAM Region Sizes” section in the Cisco Nexus 9000 Series NX-OS Security Configuration Guide.
Note The no form of this command detaches the UDFs from the TCAM region and returns the region to single wide.
Step 4| Required: copy running-config startup-config
Example:
switch(config)# copy running-config startup-config
| Saves the change persistently through reboots and restarts by copying the
running configuration to the startup configuration.
Step 5| Required: reload
Example:
switch(config)# reload
| Reloads the device.
Note Your UDF configuration is effective only after you enter copy running-config startup-config + reload.
Step 6| ip access-list span-acl
Example:
switch(config)# ip access-list span-acl-udf-only switch(config-acl)#
| Creates an IPv4 access control list (ACL) and enters IP access list
configuration mode.
Step 7| Enter one of the following commands:
• permit udf udf-name value mask
• permit ip source destination udf udf-name value mask
Example:
switch(config-acl)# permit udf udf-x 0x40 0xF0 udf-y 0x1001 0xF00F
Example:
| Configures the ACL to match only on UDFs (example 1) or to match on UDFs along with the current access control entries (ACEs) for the outer packet fields (example 2).
A single ACL can have ACEs with and without UDFs together. Each ACE can have different UDF fields to match, or all ACEs can match for the same list of UDFs.
| Command or Action| Purpose
---|---|---
| switch(config-acl)# permit ip 10.0.0./24 any udf udf-x 0x02 0x0F udf-y
0x1001
0xF00F
|
Step 8| (Optional) copy running-config startup-config
Example:
switch(config)# copy running-config startup-config
| Copies the running configuration to the startup configuration.
Configuring SPAN Truncation
You can configure truncation for local and SPAN source sessions only.
Procedure
| Command or Action| Purpose
---|---|---
Step 1| configure terminal
Example:
switch# configure terminal switch(config)#
| Enters global configuration mode.
Step 2| monitor session session number
Example:
switch(config)# monitor session 5 switch(config-monitor)#
| Enters monitor configuration mode for the specified SPAN session.
Step 3| source interface type slot / port [ rx | tx |
both ]
Example:
switch(config-monitor)# source interface ethernet 1/5 both
| Configures the source interface.
Step 4| mtu size
Example:
switch(config-monitor)# mtu 320
Example:
switch(config-monitor)# mtu ?
<320-1518> Enter the value of MTU truncation size for SPAN packets
| Configures the MTU size for truncation. Any SPAN packet that is larger than the configured MTU size is truncated to the configured size. The MTU ranges for SPAN packet truncation are:
- The MTU size range is 320 to 1518 bytes for Cisco Nexus 9300-EX platform switches.
- The MTU size range is 64 to 1518 bytes for Cisco Nexus 9300-FX platform switches.
Step 5| destination interface type slot / port
Example:
| Configures the Ethernet SPAN destination port.
| Command or Action| Purpose
---|---|---
| switch(config-monitor)# destination interface Ethernet 1/39|
Step 6| no shut
Example:
switch(config-monitor)# no shut
| Enables the SPAN session. By default, the session is created in the shut
state.
Step 7| (Optional) show monitor session session
Example:
switch(config-monitor)# show monitor session 5
| Displays the SPAN configuration.
Step 8| copy running-config startup-config
Example:
switch(config-monitor)# copy running-config startup-config
| Copies the running configuration to the startup configuration.
Configuring SPAN for Multicast Tx Traffic Across Different LSE Slices
Beginning with Cisco NX-OS Release 7.0(3)I7(1), you can configure SPAN for multicast Tx traffic across different leaf spine engine (LSE) slices on Cisco Nexus 9300-EX platform switches.
Procedure
| Command or Action| Purpose
---|---|---
Step 1| configure terminal
Example:
switch# configure terminal switch(config)#
| Enters global configuration mode.
Step 2| [ no ] hardware multicast global-tx-span
Example:
switch(config)# hardware multicast global-tx-span
| Configures SPAN for multicast Tx traffic across different leaf spine engine
(LSE) slices.
Step 3| copy running-config startup-config
Example:
switch(config)# copy running-config startup-config
| Copies the running configuration to the startup configuration.
Step 4| reload
Example:
switch(config)# reload
| Reloads the device.
Shutting Down or Resuming a SPAN Session
You can shut down SPAN sessions to discontinue the copying of packets from
sources to destinations. You can shut down one session in order to free
hardware resources to enable another session. By default, SPAN sessions are
created in the shut state.
You can resume (enable) SPAN sessions to resume the copying of packets from
sources to destinations. In order to enable a SPAN session that is already
enabled but operationally down, you must first shut it down and then enable
it.
You can configure the shut and enabled SPAN session states with either a
global or monitor configuration mode command.
Procedure
| Command or Action| Purpose
---|---|---
Step 1| configure terminal
Example:
switch# configure terminal switch(config)#
| Enters global configuration mode.
Step 2| [ no ] monitor session { session-range | all }
shut
Example:
switch(config)# monitor session 3 shut
| Shuts down the specified SPAN sessions. By default, sessions are created in the shut state.
The no form of the command resumes (enables) the specified SPAN sessions. By default, sessions are created in the shut state.
Note If a monitor session is enabled but its operational status is down, to enable the session, you must first specify the monitor session shut command followed by the no monitor session shut command.
Step 3| monitor session session-number
Example:
switch(config)# monitor session 3 switch(config-monitor)#
| Enters the monitor configuration mode. The new session configuration is
added to the existing session configuration.
Step 4| [ no ] shut
Example:
switch(config-monitor)# shut
| Shuts down the SPAN session. By default, the session is created in the shut state.
The no form of the command enables the SPAN session. By default, the session is created in the shut state.
Step 5| (Optional) show monitor
Example:
switch(config-monitor)# show monitor
| Displays the status of SPAN sessions.
| Command or Action| Purpose
---|---|---
Step 6| (Optional) copy running-config startup-config
Example:
switch(config)# copy running-config startup-config
| Copies the running configuration to the startup configuration.
Verifying the SPAN Configuration
To display the SPAN configuration, perform one of the following tasks:
Command | Purpose |
---|---|
show monitor session { all | session-number |
session-range } [ brief ]
| Displays the SPAN session configuration.
Configuration Examples for SPAN
Configuration Example for a SPAN Session
To configure a SPAN session, follow these steps:
Procedure
-
Step 1 Configure destination ports in access mode and enable SPAN monitoring.
Example:- switch# configure terminal
- switch(config)# interface ethernet 2/5
- switch(config-if)# switchport
- switch(config-if)# switchport monitor
- switch(config-if)# no shut
- switch(config-if)# exit
- switch(config)#
-
Step 2 Configure a SPAN session.
Example:- switch(config)# no monitor session 3
- switch(config)# monitor session 3
- switch(config-monitor)# source interface ethernet 2/1-3, ethernet 3/1 rx
- switch(config-monitor)# source interface port-channel 2
- switch(config-monitor)# source interface sup-eth 0 both
- switch(config-monitor)# source vlan 3, 6-8 rx
- switch(config-monitor)# source interface ethernet 101/1/1-3
- switch(config-monitor)# filter vlan 3-5, 7
- switch(config-monitor)# destination interface ethernet 2/5
- switch(config-monitor)# no shut
- switch(config-monitor)# exit
- switch(config)# show monitor session 3
- switch(config)# copy running-config startup-config
Configuration Example for a Unidirectional SPAN Session
To configure a unidirectional SPAN session, follow these steps:
Procedure
-
Step 1 Configure destination ports in access mode and enable SPAN monitoring.
Example:- switch# configure terminal
- switch(config)# interface ethernet 2/5
- switch(config-if)# switchport
- switch(config-if)# switchport monitor
- switch(config-if)# no shut
- switch(config-if)# exit
- switch(config)#
-
Step 2 Configure a SPAN session.
Example:-
1. switch(config)# no monitor session 3
- switch(config)# monitor session 3 rx
- switch(config-monitor)# source interface ethernet 2/1-3, ethernet 3/1 rx
- switch(config-monitor)# filter vlan 3-5, 7
- switch(config-monitor)# destination interface ethernet 2/5
- switch(config-monitor)# no shut
- switch(config-monitor)# exit
- switch(config)# show monitor session 3
- switch(config)# copy running-config startup-config
-
Configuration Example for a SPAN ACL
- This example shows how to configure a SPAN ACL:
- switch# configure terminal
- switch(config)# ip access-list match_11_pkts
- switch(config-acl)# permit ip 11.0.0.0 0.255.255.255 any
- switch(config-acl)# exit
- switch(config)# ip access-list match_12_pkts
- switch(config-acl)# permit ip 12.0.0.0 0.255.255.255 any
- switch(config-acl)# exit
- switch(config)# vlan access-map span_filter 5
- switch(config-access-map)# match ip address match_11_pkts
- switch(config-access-map)# action forward
- switch(config-access-map)# exit
- switch(config)# vlan access-map span_filter 10
- switch(config-access-map)# match ip address match_12_pkts
- switch(config-access-map)# action forward
- switch(config-access-map)# exit
- switch(config)# monitor session 1
- switch(config-erspan-src)# filter access_group span_filter
Configuration Examples for UDF-Based SPAN
This example shows how to configure UDF-based SPAN to match on the inner TCP
flags of an encapsulated
IP-in-IP packet using the following match criteria:
- Outer source IP address: 10.0.0.2
- Inner TCP flags: Urgent TCP flag is set
- Bytes: Eth Hdr (14) + Outer IP (20) + Inner IP (20) + Inner TCP (20, but TCP flags at 13th byte)
- Offset from packet-start: 14 + 20 + 20 + 13 = 67
- UDF match value: 0x20
- UDF mask: 0xFF udf udf_tcpflags packet-start 67 1 hardware access-list tcam region racl qualify ing-l3-span-filter copy running-config startup-config reload ip access-list acl-udf permit ip 10.0.0.2/32 any udf udf_tcpflags 0x20 0xff monitor session 1 source interface Ethernet 1/1 filter access-group acl-udf
This example shows how to configure UDF-based SPAN to match regular IP packets with a packet signature
(DEADBEEF) at 6 bytes after a Layer 4 header start using the following match criteria:
- Outer source IP address: 10.0.0.2
- Inner TCP flags: Urgent TCP flag is set
- Bytes: Eth Hdr (14) + IP (20) + TCP (20) + Payload: 112233445566DEADBEEF7788
- Offset from Layer 4 header start: 20 + 6 = 26
- UDF match value: 0xDEADBEEF (split into two-byte chunks and two UDFs)
- UDF mask: 0xFFFFFFFF
udf udf_pktsig_msb header outer l4 26 2
- udf udf_pktsig_lsb header outer l4 28 2 hardware access-list tcam region racl qualify ing-l3-span-filter
- copy running-config startup-config reload
- ip access-list acl-udf-pktsig
- permit udf udf_pktsig_msb 0xDEAD 0xFFFF udf udf_pktsig_lsb 0xBEEF 0xFFFF
- monitor session 1
- source interface Ethernet 1/1
- filter access-group acl-udf-pktsig
Configuration Example for SPAN Truncation
This example shows how to configure SPAN truncation for use with MPLS stripping:
- mpls strip
- ip access-list mpls
- statistics per-entry
- 20 permit ip any any redirect Ethernet1/5
- interface Ethernet1/5
- switchport
- switchport mode trunk
- mtu 9216
- no shutdown
- monitor session 1
- source interface Ethernet1/5 tx
- mtu 64
- destination interface Ethernet1/6 no shut
Configuration Examples for Multicast Tx SPAN Across LSE Slices
This example shows how to configure multicast Tx SPAN across LSE slices for Cisco Nexus 9300-EX platform switches. It also shows sample output before and after multicast Tx SPAN is configured.
Before Multicast Tx SPAN Is Configured
switch# show interface eth1/15-16, ethernet 1/27 counters
Port | InOctets | InUcastPkts |
---|---|---|
Eth1/15 | 580928 | 0 |
Eth1/16 | 239 | 0 |
Eth1/27 | 0 | 0 |
Port | InMcastPkts | InBcastPkts |
Eth1/15 | 9077 | 0 |
Eth1/16 | 1 | 0 |
Eth1/27 | 0 | 0 |
Port | OutOctets | OutUcastPkts |
Eth1/15 | 453 | 0 |
Eth1/16 | 581317 | 0 |
Eth1/27 | 0 | 0 |
Port | OutMcastPkts | OutBcastPkts |
Eth1/15 | 4 | 0 |
Eth1/16 | 9080 | 0 |
Eth1/27 | 0 | 0 |
Configuring Multicast Tx SPAN
- switch(config)# hardware multicast global-tx-span
- Warning: Global Tx SPAN setting changed, please save config and reload
- switch(config)# copy running-config start-up config
- [########################################] 100%
- Copy complete.
- switch(config)# reload
- This command will reboot the system. (y/n)? [n] y
After Multicast Tx SPAN Is Configured
switch# show interface eth1/15-16, eth1/27 counters
Port | InOctets | InUcastPkts |
---|---|---|
Eth1/15 | 392576 | 0 |
Eth1/16 | 0 | 0 |
Eth1/27 | 0 | 0 |
Port | InMcastPkts | InBcastPkts |
Eth1/15 | 6134 | 0 |
Eth1/16 | 0 | 0 |
Eth1/27 | 0 | 0 |
Port | OutOctets | OutUcastPkts |
Eth1/15 | 0 | 0 |
Eth1/16 | 392644 | 0 |
Eth1/27 | 417112 | 0 |
Port | OutMcastPkts | OutBcastPkts |
Eth1/15 | 0 | 0 |
Eth1/16 | 6135 | 0 |
Eth1/27 | 6134 | 0 |
Additional References
Related Documents
Related Topic | Document Title |
---|---|
ACL TCAM regions | _Cisco Nexus 9000 Series NX-OS Security Configuration |
Guide_
FEX| Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration
Guide for Cisco Nexus 9000 Series Switches