MITSUBISHI ELECTRIC PAA-A30AA1-M Multi Position Heat Pump System Owner’s Manual

June 1, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC PAA-A30AA1-M Multi Position Heat Pump System Owner’s Manual
MITSUBISHI ELECTRIC PAA-A30AA1-M Multi Position Heat Pump
System

Submittal Data: PAA-A30(A)(B)A1-M & PUZ-A30NHA7 

30,000 BTU/H Multi Position A-Coil Heat Pump System

Job Name: Location:
Purchaser: Submitted By:
Submitted To: Reference:                  Approval:

Construction:
Engineer:| Date:| Application:

PAA-A30AA1-M
PAA-A30BA1-M

Images provided for reference purposes only

Outdoor Standard Features: Description:
Blue Fin Coating Prolong condenser operating life
Inverter Motor Energy efficient operation with variable speed DC motor
Auto mode Automatically switches between heating & cooling modes
Fast Auto restart Automatically restarts after power failure return
Automated compressor cutout Prevents inefficient operation & protects

compressor
|
|
|
Indoor Standard Features:| Description:
Economic Balance Point| Allows the customer to choose the outdoor ambient temperatureto switch from heat pump to furnace
Capacity Balance Point| Allows the customer to determine the length of time(24 to 29 minutes) the heat pump will attempt to heat the space before switching to furnace (as an auxiliary heat source)
Emergency Mode| The system will operate in furnace mode when in error
Auto Restart Function| Auto-recovery after power failure(must be activated on controller mode #1 set to 2)
Description: (Optional Accessories)| Model No.
Front Windscreen| PFR-24-30
Rear Snow Guard| PRE-24-30
Side Snow Guard| PSD-24-30

“Note:

  1. To be installed by a trained and licensed refrigeration mechanic;
  2. Suitable for installation with an ANSI certified gas furnace (Z21.47/CSA2.3);
  3. Not suitable for installation with OIL or DRUM type furnaces;
  4. Supply air temperature must not exceed 200°F (93.3 °C);
  5. Furnace output capacity shall not be greater than 300% of the rated PAA cooling capacity;
  6. Configure furnace fan such at the airflow is greater than or equal to 350 CFM per ton and less than or equal to 400 CFM per ton of nominal PAA unit cooling capacity. In down flow orientation, the furnace fan should be configured to maintain an airflow face velocity below 350 ft/min to prevent water blow-off;
  7. For detailed requirements, review PAA Installation Manual at: http://www.mitsubishitechinfo.ca/

Note:

  1. Mitsubishi Electric Sales Canada Inc. (MESCA) supports the use of only MESCA supplied and approved components and accessories for proper functioning of the unit(s).
    Use of non – MESCA supported components and accessories will affect warranty coverage. MESCA recommends (A) consideration of all applicable design and application parameters and requirements specific to any project.

  2. Should any person change this document in any manner whatsoever without MESCA’s written permission, the document shall be of no force and effect and any change shall be deemed to be a representation and warranty made by that person and not MESCA. That person, and not MESCA, shall assume full responsibility for the consequences of such changes. MESCA assumes no responsibility for any consequences in such cases.

Performance

Cooling at 95°F*1 Rated Capacity Btu/h 30,000
Capacity Range Btu/h 9,600 – 30,000
Rated Power Input W 3,000
Power Input Range W 650 – 3,000
Moisture Removal pints/h 6.8
Sensible Heat Factor 0.75
Heating at 47°F*1 Rated Capacity Btu/h 32,000
Capacity Range Btu/h 13,100 – 35,200
Rated Power Input W 2,640
Power Input Range W 900 – 2,640
Heating at 17°F*2 Maximum Capacity Btu/h 20,800
Rated Capacity Btu/h 20,800
Capacity Range Btu/h 8,100 – 20,800
Maximum Power Input W 2,370
Rated Power Input W 2,370
Power Input Range W 900 – 2,370
Heating at 5°F*3 Maximum Capacity Btu/h 18,700
Maximum Power Input W 2,000
Heating at -5°F Maximum Capacity Btu/h 15,600
Maximum Power Input W 1,800

Efficiency:

SEER / SEER2 16.0 / 15.2
EER / EER2 10.0 / 9.50
HSPF / HSPF2 (IV) / (V) 10.0 / 8.80 / 6.9
COP at 47°F*1 Rated Capacity
COP at 17°F*2 Maximum Capacity
COP at 5°F*3 / -4°F Maximum Capacity

Electrical:

Power Supply 208/230V, 1Ph, 60Hz
Voltage: Indoor – Outdoor, S1-S2 V AC
Voltage: Indoor – Outdoor, S2-S3 V DC
Short-circuit Current Rating (SCCR) kA
Recommended Fuse/Breaker Size (Outdoor) A
Recommended Wire Size (Indoor – Outdoor) AWG

Outdoor Temperature Operation Range:

Cooling| °F (°C)| *4 0 to 115 (-18 to 46)D.B -4 to 70 (-20 to 21.1), W.B. -4 to 59 (-20 to 15)
---|---|---
Heating| °F (°C)
Cooling Operation Thermal Lock-out / Re-start Temperatures| °F (°C)| -1.3 / 3.2 ( -18.5 / -16.0)
Heating Operation Thermal Lock-out / Re-start Temperatures| °F (°C)| -8.5 / -4.9 ( -22.5 / -20.5)

AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)

NOTES :

  1. Rating conditions (cooling)-Indoor: D.B. 80°F (26.7°C), W.B. 67°F (19.4°C) Outdoor: D.B. 95°F(35°C), W.B. 75°F (23.9°C) (heating)-Indoor: D.B. 70°F (21.1°C), W.B. 60°F (15.6°C) Outdoor: D.B. 47°F (8.3°C), W.B. 43°F (6.1°C)
  2. Conditions (heating)-Indoor: D.B. 70°F (21.1°C), W.B. 60°F (15.6°C) Outdoor: D.B. 17°F (-8.3°C), W.B. 15°F (-9.4°C)
  3. Conditions (heating)-Indoor: D.B. 70°F (21.1°C), W.B. 60°F (15.6°C) Outdoor: D.B. 5°F (-15°C), W.B. 5°F (-15°C)
  4. Cooling at 0 °F, wind baffle accessory required. Without wind baffle accessory, the minimum temperature will be 23°F (-5°C).
    A) CFM @ 350 per tons.

Indoor Unit Specifications

Models Airflow rate* W: In. D: In. H: In. W: mm D: mm H: mm kg (lbs)
PAA-A30AA1-M 875 14.5 21.3 26.4 368 543 670 22 (48)
PAA-A30BA1-M 875 17.5 21.3 26.4 445 543 670 26 (58)
* Target airflow rate for Y or Y1 signal Not including connection pipes.
Internal static pressure in. WG 0.3 (According to AHRI – 210/240, where this

is the maximum allowable internalstatic pressure for “Coil Only” systems)
[Pa]| 75 (According to AHRI – 210/240, where this is the maximum allowable internalstatic pressure for “Coil Only” systems)
MCA| A| 0.2
Drain Pipe Size| In. (mm)| 3/4 (19.05)
External Finish Color| Galvanized Steel

Outdoor Unit Specifications:

MCA A 19
MOCP A 26
Fan Motor Output kW 0.086
Airflow Rate (Cooling/Heating) CFM 1,940 / 1,940
Sound Pressure Level, Cooling1 dB(A) 47
Sound Pressure Level, Heating2 dB(A) 48
Refrigerant Control Electronic Expansion Valve
Compressor Oil Type / Charge oz. FV50S (23)
External Finish Color Ivory Munsell 3Y 7.8/1.1
Unit Weight kg (lbs) 69 (153)
Unit Dimensions W: In. (mm) 37-13/32 (950)
D: In. (mm) 13 + 63/64 (300 + 25)
H: In. (mm) 37-1/8 (943)
Gas Pipe Size O.D. (Flared) In. (mm) 5/8 (15.88)
Liquid Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52)
Maximum Height Difference Ft. (m) 100 (30)
Maximum Piping Length Ft. (m) 100 (30)

Description: (Optional Controls)

Wired wall mounted remote control PAR-41MAAU
Wireless wall mounted remote control MHK2
North American T-Stat Interface RMF-CA100

Indoor Unit Dimensions:

Model| A mm (inches)| B mm (inches)| C mm (inches)| D mm (inches)| E mm (inches)
---|---|---|---|---|---
PAA-A30AA1| 368.3| 313.1| 332.7| 670.2| 543
| (14-1/2)| (12-5/16)| (13-1/16)| (26-3/8)| (21-3/8)
PAA-A30BA1| 445.0| 390| 409.6| 670.2| 543
| (17-1/2)| (15-5/16)| (16-1/8)| (26-3/8)| (21-3/8)

Indoor Unit Outline and Dimensions

Outline and Dimensions
Outline and Dimensions
Outline and Dimensions
Outline and Dimensions
Outline and Dimensions

Symbols Symbols
www.MitsubishiElectric.ca
© 2023 Mitsubishi Electric Sales Canada Inc.

Specifications are subject to change without notice. Form
No. SB_PAA-A30(A)(B)A1-M_PUZ-A30NHA7_202403

MITSUBISHI ELECTRIC Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals