Honeywell CS076AE Portable Evaporative Air Cooler User Manual
- June 1, 2024
- Honeywell
Table of Contents
Model : CS076AE Series
Portable Evaporative Air Cooler
User Manual
http://honeywellaircomfort.com/
www.HoneywellAirComfort.com
E-mail: support.eu@jmatek.com
Read and save these instructions before use
PARTS DESCRIPTION
- Control Panel
- Power Cord & Plug
- Louvers
- Water Level Indicator
- Casters
- Ice Compartment Lid
- Handle
- Rear Grill
- Honeycomb Cooling Media with Antibacterial treatment+
- Water Tank
- Water Tank Knob
WARNING — READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND
USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS
MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE
IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER
LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL
PREVAIL.+
Antibacterial Honeycomb is up to 99%A effective in killing certain types of
bacteria through 48 hours of continuous use.
A Based on independent laboratory testing (report #2020FM2738), testing the
antibacterial and cleaning function of the honeycomb cooling pads against
Escherichia coli (strain #ATCC8739), Staphylococcus aureus (strain #ATCC
6538P), Klebsiella neumoniae (strain #ATCC 4352) , as per testing standard
JIS L 1902:2008 designed for testing antibacterial and cleaning functions for
household, and similar electrical appliances.
USE & OPERATION
CONTROL PANEL
POWER
Press the button to turn the unit on. The cooler will start automatically at
medium speed. After a few seconds the speed will switch to low. To turn the
unit off, press the button again.
SWING
Press the button until the indicator light is illuminated on the
control panel. The louvers will begin to move left to right automatically.
Vertical Air Flow – You can manually adjust the louvers to change vertical air
flow. TIMER
Press the button until the desired time duration setting is selected. When the
set time has passed, the unit will automatically turn off (unit remains in
Standby mode until power cord is unplugged from electrical socket). The
function allows you to program the unit for up to 7.5 hours of use.
SPEED
Press the button repeatedly to change the speed between Ⅲ( High)- Ⅱ(Medium) –
Ⅰ( Low).
WIND TYPE
Press the button to select your desired wind type: Random or Sleep **
Random: This mode mimic a natural breeze.
Sleep: This mode is for comfort during the night.
COOL & IONIZER*^*
Press the button until the indicator light is illuminated on the control
panel. This activates evaporative cooling and the Ionizer^ is automatically
activated. The water pump will operate and you will feel the cooler air after
the Honeycomb Cooling Media is completely wet.
Note: When the indicator light is switched OFF, the unit can still
function in a fan only mode (without evaporative cooling and the Ionizer*^
function).
- Applicable for models with Ionizer feature only.
^An ionizer helps to reduce particles in the air. This is not an air purifier.
REMOTE CONTROL
**** | POWER | ON/OFF |
---|---|---|
SPEED | Ⅲ(High) – Ⅱ(Medium) – Ⅰ(Low) | |
**** | SWING | Controls the motion of the louvers |
TIMER | Controls the Timer function for automatic off | |
COOL & ION*^ | Controls the Cooling with Ionizer*^ functions or Fan only | |
WIND TYPE | Switch between Random & Sleep |
NOTE:
- The remote control requires a CR2025 (3V) coin type or equivalent battery for replacement.
- Open the battery compartment at the back of the remote control and insert the battery inside.
- Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment.
- Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed.
- Remove the batteries if the unit is not going to be used for an extended period of time.
- Do not drop the remote control.
- Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries.
- Do not mix old and new batteries.
- Do not recharge the battery.
- Exhausted batteries are to be removed from the product and safely disposed of as per local regulations.
- Do not dispose of batteries in fire. Batteries may explode or leak.
- This product contains a lithium button/coin cell battery. If a new or used lithium button/ coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
- The batteries shall be disposed of properly, including keeping them away from children.
- Even used batteries may cause injury.
WARNING: Chemical Burn Hazard. Keep batteries away from children.
COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start
using the productPlease refer to the COOLER LOCATION section of the separate
Safety & Maintenance Guide.
FILLING WITH WATER **
**
CAUTION:
Unplug the unit from the electrical power outlet before emptying or refilling
the water tank.
To refill, rotate the water tank knob and slide out the water tank located at
the back of the unit.
The Water Level Indicator is
located at the front of the unit and water tank. Refill the water tank when
water level is low. Do not fill water above the “Max.” water level mark to
avoid water droplets collecting on the louvers. Check the water level in the
tank before running the COOL function. Make sure that the water in the tank is
above the minimum water level mark. Running the unit in COOL mode with
inadequate water may cause pump failure.
STEP 1:
Unlock the water tank by turning the lock anti-clockwise, then pull out half
of the water tank.
STEP 2:
Fill the tank with clean water, push back the half water tank, turn the lock
clockwise to lock the water tank in place.
Note: The water capacity refers to the total volume of water that can be
contained within the air cooler water tank and water distribution system.
The water capacity in the tank at the “Max.” indicator level may be lower than
the actual water capacity of the air cooler.
Note: If ice is available, you may add ice in the top ice compartment to
enhance the cooling performance.
WARNING: Do not fill water tank with dirty water or salt water. This can
damage the unit and Honeycomb media.
*LOW WATER ALARM
* The unit is equipped with a low water sensor. In Cooling & Ionizer^ mode ,
when water in the tank is below the minimum level, you will hear a beeping
sound and the indicator light will flash continuously. The unit will
automatically pause evaporative cooling and ionizer^ function.
Refill the water tank to deactivate the alarm in Cooling mode . First switch
OFF the unit and unplug from the power outlet. Fill the water tank with water
above the minimum water level mark. Plug in and switch ON again.
To deactivate the alarm and continue using the unit as a fan (without
evaporative cooling), switch the unit OFF and then ON again. The Low Water
Alarm will not activate in Fan only mode. The Low Water Alarm will sound again
if the function is activated while the water tank is still empty.
Applicable for models with this feature only.
^An ionizer helps to reduce particles in the air. This is not an air purifier.
CLEANING & DRAINING THE WATER TANK
Below are instructions on how to clean and maintain your air cooler. If the
cooler will not be used for a long period of time, please refer to the STORAGE
& MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide.
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the
electrical socket.
- To completely remove the water tank, remove the pump first. Move the unit to a location where the water can be drained, pull the half of the water tank, press the water pump two side clamps (See Figure 1) to make sure pump leaves fixed position then pull out the water tank.
- Refill the water tank with clean water, up to the maximum level and drain it completely.
- Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
- When the product is not in use, store the unit in a dry place out of direct sunlight.
CLEANING THE MESH FILTER AND HONEYCOMB COOLING MEDIA WITH ANTIBACTERIAL TREATMENT⁺
- The appliance is supplied with a Mesh Filter and Honeycomb Cooling Media with Antibacterial treatment⁺.
- The Mesh Filter is combine with rear grill, honeycomb cooling media is located inside the Rear grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
- Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time.
- The cleaning frequency for the Honeycomb Cooling Media with Antibacterial treatment⁺ depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media with Antibacterial treatment⁺ and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media with Antibacterial treatment⁺, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.
- For best results allow the Honeycomb Cooling Media with Antibacterial treatment⁺ to dry after each use by turning off the cool function 15 minutes before turning the unit off.
Removing the Honeycomb Cooling Media with Antibacterial treatment⁺ :
- Remove all the screws from the Rear Grill of the Air Cooler.
- Carefully pull out the Rear Grill from the Cooler.
- Slide out the Honeycomb Cooling media with Antibacterial treatment⁺.
- Rinse under fresh water to remove dust and dirt on Filter and Honeycomb.
- Replace or clean media with water and a damp cloth as needed.
WARNING: DO NOT operate the Air Cooler when the Rear Grill is removed
from the Air Cooler, or if there is a loose-fitting Rear Grill. Doing so can
cause serious injury or dangerous electrical shock.
+Antibacterial Honeycomb is up to 99% A effective in killing certain types of
bacteria through 48 hours of continuous use.
A Based on independent laboratory testing (report #2020FM2738), testing the
antibacterial and cleaning function of the honeycomb cooling pads against
Escherichia coli (strain #ATCC8739), Staphylococcus aureus (strain #ATCC
6538P), Klebsiella Pneumoniae (strain #ATCC 4352) , as per testing standard
JIS L 1902:2008 designed for testing antibacterial and cleaning functions for
household, and similar electrical appliances.
JMATEK UK limited
Keizersgracht 62
1015 CS Amsterdam
Netherlands
Tel: +31 20 5207422
Support.eu@jmatek.com
Made in China
© 2024 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license from Honeywell International
Inc.
Honeywell International Inc. makes no representations or warranties with
respect to this product.
This product is manufactured by Airtek Int’l Corp. Ltd.
(subsidiary of JMATEK Ltd.).
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>