scala SC 1080 Animal Thermometer
Product Information
- Specifications
- Type: Maximum thermometer
- Measuring Range: Display L for low, display H for high
- Self-test: Display 3-digit liquid-crystal (LCD display)
- Battery Type: 1 no.: LR 41 or SR 41
- Battery Display: Shows when the battery is discharged
Product Using Instruction
- Usage Instructions
- Press the I/O button to switch on the thermometer. A short signal tone indicates the device is on.
- After use, press the I/O button briefly to turn off the device. The temperature value remains displayed until switched off.
- To display the last measured value, press and hold the I/O button for more than three seconds. Release the button to prepare for new measurements.
- Cleaning and disinfection can be done by wiping with approved disinfection agents or a moist cloth. Note the device is watertight but not resistant to aggressive disinfection solutions.
- The Animal Thermometer SC 1080 is designed for the rectal measurement of body temperature in large animals.
- It is a maximum thermometer, displaying the highest temperature after 25 seconds. The device saves the most recent measured value for reference.
- Changing the Battery
- When the battery symbol appears indicating discharge, follow these steps to replace the battery:
- Pull off the cover of the battery compartment.
- Remove the used battery with a pointed object.
- Insert a new LR41 or SR41 battery, ensuring it is placed correctly.
- Disposal Note
- Dispose of defective or retired devices at designated collection points for old electrical items.
- Batteries should be disposed of correctly at battery dealers or communal collection points to prevent environmental risks.
FAQs
- Q: Can this thermometer be used for small animals?
- A: No, the SC 1080 is specifically designed for measuring body temperature in large animals only.
- Q: How do I know when to change the battery?
- A: The battery symbol will appear on the display when the battery is discharged and needs replacement.
Special features
- The SC 1080 is a maximum thermometer, i.e. the highest temperature is displayed the latest after 25 seconds.
- The most recent measured value is Balways saved.
Safety information
- The thermometer is suitable only for measuring animal body temperatures.
- The thermometer contains small parts (batteries, etc) which could be swallowed by small children. Please keep the thermometer and its batteries out of the reach of small children.
- Protect the SC 1080 from direct sunshine and temperatures above 50°C.
- Never drop the SC 1080, do not bend or open it (except the battery compartment for battery replacement).
Operating manual
Press the I/O button to switch on. A short signal tone shows that the device is in the “switched on” condition. A segment test takes place simultaneously (checks all display segments and carries out an internal function test (see under “Function test”))
After this, if the temperature measured by the temperature sensor is less than 32°C, the display shows an “L“ and “°C“. After around one second, the “°C“ starts to blink. The „L“ stands for low (less than 32°C). The current temperature is continuously displayed during measurement, and the “°C” blinks during the entire measurement time. The measurement is completed after around 25 seconds.
After the measurement is completed, the temperature value measured remains in the display until the SC 1080 is switched off. To turn the device off after use, press the I/O button briefly. The signal tone will again be sounded. If the device is not switched off, a signal tone is sounded after around 3 minutes and the device then switches off automatically.
Function test
The thermometer is checked for correct functioning automatically every time it
is switched on. All segments are displayed, and then L°C. If a failure
(measurement inaccuracy) is recognised, “ERR“ (Error) is shown in the display.
Display of last measured value
If you keep the I/O button pressed for longer than three seconds, the last
measured value will be shown on the display. As soon as you release the I/O
button, the device is ready to take measurements.
Cleaning and Disinfection
The veterinary thermometer is watertight. Please note that being watertight does not mean that the thermometer is also tight in aggressive disinfection or solvent solutions! The thermometer can be cleaned by wiping with any of the disinfection tissues listed below or with a moist cloth containing any of the following disinfection agents.
Disinfectant | Supplier | Use |
---|---|---|
Kodan® tissues | Schülke & Mayr | |
EuroSept® Max | Henry Schein Inc. | According to |
Wipes | supplier | |
Medizid Rapid | Rösner-Maut by Meditrade | instructions for |
GmbH | plastic surfaces | |
Helipur® H plus N | B. Braun Melsungen |
Guarantee
- We give a guarantee period of 2 years from the date of purchase.
- We guarantee the perfect design of this article.
- We will rectify all material or manufacturing errors during the guarantee period.
- If, contrary to expectations, defects are found, please send the device back to our customer service department.
- Please enclose the proof of purchase and a description of the defect so that the problem can be rectified as soon as possible.
- The guarantee excludes damages caused by improper handling, related to the battery or the packaging.
Specifications
- Type: maximum thermometer
- Measuring range: 32.0°C to 43.9°C
- Temperature below 32.0°C: display “L“ for low.
- Temperature above 43.9°C: display “H“ for high.
- Measurement accuracy: +/- 0.1°C between 35.5°C and 42.0°C at a ambient temperature of 18°C to 28°C.
- Self-test: Automatic internal check of test value 37.0°C. In case of deviation > 0.1°C, “Err“ will be displayed.
- Display: 3-digit liquid-crystal (LCD display).
- Battery type: 1 no.: LR 41 or SR 41.
- Battery display: The shows when the battery is discharged.
- Storage temperature: 0°C to 50°C
Changing the battery
- As soon as the symbol appears in the display, the battery has run out and requires replacement.
- Always replace the discharged battery with one of the same type. To do this, proceed as follows:
- Pull the cover off the battery compartment.
- The battery can now be accessed.
- Remove the used battery with the help of a pointed object (pincers, small screwdriver etc.) and put the new battery (LR 41 or SR41) in.
- Please make sure it is the right way around.
Disposal note
- Defect devices or devices that are taken out of operation at the end of their service life may still contain residues that could present a risk to the environment. Please dispose of the device suitably and correctly at a collection point for old electrical items.
- Batteries must be disposed of correctly. There are containers for battery disposal at battery dealers and in communal collection points.
Explanation of symbols
CONTACT
- Scala Electronic GmbH
- Ruhlsdorfer Straße 95
- 14532 Stahnsdorf
- www.scala-electronic.com.
- Rev. 25/04/2022/GB
- Animal Thermometer SC 1080 for the rectal measurement of body temperature in large animals.