Vive Health LVA3019BGE Standard Alternating Pressure Pad User Guide

June 1, 2024
vive health

Vive Health LVA3019BGE Standard Alternating Pressure Pad User Guide

Vive Health LVA3019BGE Standard Alternating Pressure Pad User
Guide

vhealth.link/f9c

vivehealth.com

Vive Health LVA3019BGE Standard Alternating Pressure Pad User Guide -
Product Overview

  1. Unroll the Pressure Pad and lay it flat on your mattress. Make sure the inflation tubes are facing up and positioned at the head or foot of the bed depending on w here you plan to place the ‘ Pressure Pump.
  2. Use the built in metal hooks to hang the pressure pump over the bed frame at the foot of the bed (recommended). You may also lay the pump flat on a table.
  3. Connect the two inflation tubes to the pressure pump and pressure pad.Vive Health LVA3019BGE Standard Alternating Pressure Pad User Guide - Connect the two inflation tubes
  4. Plug the pressure pump into a standard US 11OV electrical outlet.
  5. Turn the pump on and adjust the pressure dial to the “Firm” setting to speed up inflation. Wait until the mattress has been fully inflated before using (inflation time: Approx. 8 min) .
  6. Adjust the pressure dial to find the most comfortable setting for the user.

HOW IT WORKS

The Vive Alternating Pressure Pad Lite has 760 bubble air cells. The air cells are divided into two different sections. Each section is connected separately to the pressure pump. The pressure pump automatically alternates between sections in 6 minute intervals. The pressure dial on the front of the pressure pump allows you to adjust the pad pressure from soft to firm. Regard less of the pressure setting the pump will always alternate in 6 minute intervals.

Vive Health LVA3019BGE Standard Alternating Pressure Pad User Guide - How it
work

CLEANING INSTRUCTIONS

Use cloth with a mild detergent solution or a surface detergent/disinfectant for cleaning the pad and hose.
Wipe down the pump with a dry cloth.

REPAIR GUIDE

Small Punctures: Use the patch kit.

  1. Fully deflate the unit.
  2. Take the patch and add glue around the edges.
  3. Firmly place the patch over the puncture. Hold for 20 seconds until the glue is dried.
  4. Let stand for 30 minutes.

SPECIFICATIONS

Pump

  • Interval duration: 6 mins
  • Air Output: 6-7 L/Min
  • Pressure Range: 35~130 mm Hg
  • Electrical Power Supply: 110-120 Volts Mattress
  • Dimensions: 36″ x 78″ x 3″ (inflated)
  • Materials: PVC (EN-71) 0.3 mm

Mattress

  • Dimensions: 36″ x 78″ x 3″ (inflated)
  • Materials: PVC (EN-71) 0.3 mm

WARNING ⚠

  • Weight Capacity: 300 lbs
  • Do not use corrosive cleaning products such as industrial degreasers or acetic solvents.
  • Keep away from sharp objects as they may puncture the pressure pad.

Vive Health LVA3019BGE Standard Alternating Pressure Pad User Guide - Thank
you page

www.vivehealth.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals