Laser Engraver
Always read the instructions before you start.
Before You Start
1.1 Disclaimer and safety Guidelines
-
The laser engraver emits laser light. Placing any living body under the laser emission port (marked with an orange warning sign) is strictly forbidden.
-
Patients with photosensitive epilepsy are prohibited from using or approaching the laser engraver.
-
When using the laser engraver, the operator and anyone near the machine must wear laser safety goggles. Operating the laser engraver without goggles’ protection is not allowed. Our machine comes with a pair of safety goggles, but additional laser safety goggles need to be purchased separately.
The goggles should offer wavelength protection of 400-445m(±5m), an outer diameter of +5, and a minimum L-level L5. -
Avoid placing flammable materials near the laser engraver. When the laser engraver is running, closely observe it and avoid leaving it unattended to prevent the engraved objects from catching fire. Set up the laser engraver in a fireproof area and ensure proper ventilation.
If possible, we recommend purchasing a fire extinguisher and keeping it nearby the machine. -
Ensure there is enough space when operating the laser engraver. Engraving certain materials may produce smoke, so it’s important to use exhaust equipment to vent the smoke out.
-
When the machine is running, avoid letting your body or other objects touch the laser beam, as this may cause serious bodily injury or beam reflection. Do not touch the radiator, as it may still be hot even after the laser engraver has stopped working.
-
Do not allow children or teenagers to use the laser engraver alone, especially children under the age of 14. Adult supervision is required at all times.
-
The operating temperature range of the machine is -10°C to 40°C.
-
The use of the laser engraver carries a significant risk of fire. When operating the machine, please ensure that someone is available to handle any potential fire emergencies at all times.
1.2 Parts List
1.2.1 Machine
- The above images are for reference only. Please refer to the actual product.
Machine Assembly
01/ 18
Assemble the Frame
Step 1 : Place the Front Frame and Rear Frame ends flush with the sides
of the Left Y-Axis Frame. and Right Y-Axis Frame.
Secure using M5X25 Screws.
02/ 18
Assemble the X-Axis Component.
Step 2: Fit the X-Axis into the left Y-Axis Frame.
Fit the X-Axis into the right Y-Axis Frame.
03/ 18
Flip the Machine
Step 3: Flip the machine upside down, with its bottom facing up.
04/ 18
Assemble the L-Bracket.
Step 4: Align the L-Bracket with the frame mounting holes.
Secure using M5X14 Screws.
05/ 18
Assemble the L-Bracket.
Step 5: Using the same method, install the remaining three L-Brackets.
Secure using M5X14 Screws.
06/ 18
Assemble the Support Feet.
Step 6: Screw the Support Feet into the corresponding mounting holes on the L-Brackets in a clockwise direction.
07/ 18
Flip the Machine Again
Step 7: Flip the machine upside down with the top side facing upwards.
08/ 18
Assemble the End Plate.
Step 8: Align the End Plate with this hole.
Secure using M5X14 screws.
09/ 18
Assemble the Belt
Step 9: Thread the belt through the hole in the direction of the arrow.
Secure the belt using M5X8 screws and M5X15X1 washers.
10/ 18
Assemble the Belt
Step 10: The belt passes through the hole at the other end along the Y-Axis.
Do not twist the belt, ensure it remains flat.
Secure it M5X8 screws and M5X15X1 washers.
11/ 18
Check the tension of the belt
Step 11: Gently move the X-Axis by hand to check the belt tension. If it’s too loose or tight, adjust accordingly.
12/ 18
Assemble the Limit Switch.
Step 12: Secure the Limit Switch Mounting Plate using M2.5X6 screws.
Secure the Limit Switch using M2X9 screws.
13/ 18
Assemble the Laser Module
Step 13: Insert the rear dovetail groove of the Laser Module into the
corresponding slot on the fixture.
Tighten the screw clockwise to secure it in place.
14/ 18
Assemble the Control Box Component
Step 14: Align the installation nut on the back of the Control Box with the
mounting hole on the Front Frame.
Secure it by using M5X14 screws.
15/ 18
Assemble the main cable
Step 15: Insert the cable connectors into the Limit Switches, Motors, and Laser Module Sockets in the sequence shown in the picture.
16/ 18
Assemble the main cable
Step 16: Secure the cables in the appropriate positions using zip ties.
17/ 18
How to Focus
Step 17: First, place the Focus Assist on the engraving material, ensuring it
is positioned beneath the laser module. Gently slide the laser module downward
until its edge lightly touches the circular disc on the bottom of the Focus
Assist. Once in this position, tighten the laser module’s Thumbscrew to secure
it.
Finally, remove the Focus Assist from underneath the laser module.
18/ 18
Complete
Step 18: The type-C to USB cable is used to connect the computer and machine. Ensure that the type-C end is plugged into the laser machine, while the USB end is plugged into the computer.
How to Use
3.1 Machine Status Explanation
Status | Action | LED Indicator Descriptions | Result |
---|---|---|---|
Power on | Power button short press <0.5s | gradually brightens The white LED |
Power on Machine quickly seeks Machine powers on and for machine zero point
Power off| Power button long press >1.5s| The white LED gradually dims| Power
off Machine shuts down Machine powers off and stops all operations
Enter upgrade mode| Press and hold the power button while
simultaneously pressing the RESET button on the control board when
the machine is in the power-off state| The red, green, and blue LEDS flash
alternately| Power off Machine shuts down Machine powers off and stops all
operations
Enter network configuration| Power button continuous short press 5 times| The
lights transition Into a colorful gradient| The machine can configure network
information the APP
Control board reset| Press the RESET button briefly| The lights transition
into a colorful gradient| The machine can configure network information
through the APP
Standby| When the machine is powered on and Idle| The white light breathes in
and out| The machine Is In Idle standby state
Working| When the machine is powered on and
in operation| The cyan-blue light remains steady| The machine is in motion
processing state
Fault indicator| When the machine encounters a malfunction and cannot perform
engraving movemen| The yellow light slowly flashes and accompanied by a “di,
du” sound| The machine cannot engrave there is a malfunction
3.2 How to connect the machine to a PC
Install the driver: Before installing the computer driver, please power on the
machine and connect it to the PC using a USB cable.
Then, choose the appropriate driver file based on your computer system and
proceed with the installation.
Operating System | Operation | Phenomenon |
---|---|---|
WIN 7/WIN 8 | To install the driver, make sure the machine is powered on and |
connected to the computer via USB.
The installation process can only be carried out when the machine is in the
powered-on state and connected to the computer.
WIN 10/WIN 11| No installation required|
Mac| No installation required|
To check the driver installation, follow these steps:
① Find the Device Manager on your computer.
② Navigate to the Ports section.
③ Disconnect the USB cable from the computer.
④ Observe that the new serial port disappears from the Ports section.
⑤ Reconnect the USB cable.
⑥ Verify that a new serial port appears, indicating successful driver
installation.
Connecting the machine
① Launch the LaserGRBL / LightBurn software.
② Select the COM port that corresponds to the one identified in step two of
the installation process.
③ Click on the “Connect” button.
④ If a welcome message appears in the command box, it indicates a successful
connection.
For resolving driver issues on Windows 7/8, you can follow these steps Resolution for Driver issues on ESP MCU Espressif CDC Device Error (Applicable to WINDOWS 7/8 )
Click on the download link to download the file: Zadig-2.5.exe
Download: https://zadig.akeo.ie/
Once download is complete, please run the application with Administrator
Rights.
Once open select List All Devices from the menu Options.
Wait for the refresh
Select Espressif CDC Device (Interface 0) from the drop-down list.
Select USB Serial (CDC) from the list of drivers available, click the Install Driver button, and wait for the installation to complete.
When you’re done, you can close the Zadig software.
The New Espressif CDC Device (Interface 0)(COM X) port in Device Manager. Note
the COM number might be different in your machine.
3.3 YRR/YRC Connection — Operation description
Connection: Unplug the Y-axis motor wire from the Y-axis motor and connect it
to the corresponding motor jack of YRR/YRC.
Connect the control terminal: Use USB or other methods to connect the
computer.
LaserGRBL: Send “$22=0” in the “Type gcode here ”field
LightBurn: Send the command “$22=0” in the “(Type Commands here)” field.
3.4 FAQ
No response from the machine when being powered on.
- No power supply: Please check the socket and switch as well as the machine power socket to ensure that they ha been correctly plugged with normal power supply.
It cannot be connected to computer.
-
USB cable not connected: Please check the USB data cable interface on the machine and computer to ensure it’s correctly plugged.The USB interface on the front panel of some desktop computers is invalid, it’s better to connect to the interface on the back.
-
Driver not properly installed: Install the driver according to the instructions.
After the installation is done, the computer will recognize the device as a serial port,which means the hardware connection is OK. -
Other special problems:Pull out the USB data cable and power cable, keep the machine power off for 5 seconds and then try the connection once again.
No response from the phone APP when being connected to the machine.
- Wrong Bluetooth connection: Make sure it’s connected to the Bluetooth released by the machine. Please read “App Connection” in the User Manual for details.
- Incompatibility: In the case of abnormal connection due to incompatibility of newly-released phone or upgraded system, please contact our customer service with the screenshot of phone configuration so as to get technical support as soon as possible.
Shallow engraving effect or no traces.
- Inaccurate focus: Refer to the “Focus Adjustment” in the User Manual to make the correct focus.
- Engraving speed: Too fast speed is due to short burning time.Please read the“Engraving Parameters” in the Manual to readjust the parameters.
- Photo color is too light: The photo added should be clear. If the line is too thin or the color is too light, the engraving effect will be directly influenced.
- Position of object to be engraved: If the object is placed obliquely, the focal length of laser is fixed,so the object should be placed horizontally in parallel to the machine; otherwise, the inaccurate focal length will result in bad engraving effect.
Offline engraving unexpectedly stops
- The photo is not completely downloaded when being connected to computer, please download the photo once again.
FCC Compliance Statements
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna,
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ISED Compliance Statements
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment.
RF Exposure Compliance
This equipment complies with FCC/IC RSS-102 radiation exposure limits set
forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body,
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
MADE IN CHINA