ALEKO 10×8 Luxury Remote Controlled Automatic Retractable Half Cassette User Guide
- June 1, 2024
- ALEKO
Table of Contents
Half Cassette Awning Assembly Guide
Have a
question or an issue?
Were here to help!
Call or email us
and one of our Product Experts
will help you find a solution.
REPAIR MANUAL
|
CASE OF MALFUNCTION
| REASON|
REPAIR METHOD
1
| The awning does not work when operated by the remote control.|
- There is no power supply.
- The residual current automatic circuit breaker is turned to “off.”
- The voltage is too low.
|
- Check the plug to see whether it is properly connected.
- Call a professional to inspect.
- Call a professional to inspect the voltage.
2
| When operated by remote control, the awning does not work, although you can hear the signal sound from the remote control receiver.|
- The remote receiver and motor are switched or the wire from the motor is disconnected.
- The motor switched off due to the overheat protection.
|
- Check two places: fasten pins, and the screws.
- The motor will automatically resume operation after approximately 20 minutes.
3
| The fabric is loose, even though the awning is extended entirely.| The path length is incorrectly adjusted.| Readjust the path length according to the direction of the motor.
4
| The cassette can’t close completely.| The connecting position between the front bar and the front beam.| Adjust the position of the front beam until the cassette is entirely shut.
5
| There is unwanted noise when operating the awning.| There is a loose screw.| Check all screws to ensure that they are tightly fastened.
6
| When operated by a remote control, the indicative lamp does not work and there is no signal from the receiver.|
- The cell is exhausted.
- The cell is disconnected.
|
- Replace with a new cell.
- Reset the cell.
ALEKO Tubular Motor Instructions
AC Tubular Motor
1. Up Limit Setting
If Motor is not functioning, do not continue rotating red or white worm.
- Switch on
- Press UP button one time
- Using special regulator tool, rotate white worm clockwise to increase the UP distance
- When UP limit distance achieves the desired location, stop rotating white worm and press the STOP button.
- Up Limit setting is programmed
2. Down Limit Setting
Please do not use regulator to adjust red and white limit screw when the tubular motor is stopped.
- Switch on
- Press DOWN button one time
- Using special regulator tool, rotate red worm clockwise to increase the down distance.
- When DOWN limit distance achieves the desired location, stop rotating red worm and press the STOP button.
- Down Limit setting is programmed
3. Common failures and solutions
| Failure Symptoms| Failure Causes| Solutions Failure Recovery
---|---|---|---
1
| Switch is on, the drive adapter runs in one-way operation| Inside limit switch Of motor is not opening.| Adjust Red or White worm until Awning moves.
2
| Motor starts slowly or does not work after power is connected.| a. Power
voltage is low
b. Wiring error
c. Overload
d. Improper Installation| a. Adjust power to proper rating.
b. Check circuit and correct wiring connections.
c. Ensure rated torque is not being exceeded.
d. Re-install the motor.
3
| Motor stops suddenly after running| Motor has Overheated.| Motor will automatically resume after 20 minutes of cooling.
4
| Abnormal sound, Roller binds during operation.| Tubular motor is overtightened to roller support.| If idler is active, slightly adjust screws attaching motor and roller support bracket to loosen.
Attention
- Motor Working Temperature: 14°-120°F
- Operational Voltage: 110V
Do Not Expose Tubular Motor element to water at any time.
Do not pound the Tubular Motor into place.
Do not drill into the motor assembly for any reason.
Ensure Slack in the power Cord to allow moisture to run off before reaching electric motor.